| Plan Review Stops For Permit 23061371 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-07-19 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-07-19 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-07-03 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-07-03 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-19 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-19 |
Time |
11:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-06-30 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-06-30 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2023-06-30 13:39:57 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 2.PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | | IS REQUIRED TO BE SIGNED AND SEALED BY THE PERSON | | | RESPONSIBLE FOR THE DESIGN. A DIGITAL PLAN REQUIRES A | | | DIGITAL SIGNATURE WITH THE PROPER THIRD PARTY | | | VERIFICATION. SELF-CERTIFICATION IS NOT ACCEPTABLE. WPB | | | FBC 107.1; FS 471/481 | | | 3.PROVIDE ELECTRICAL PLAN FOR REVIEW. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-13 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-06 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2023-07-06 09:39:22 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS NO CLEAR INDICATION OF WHERE THE TWO (2) | | | CLEAR EXIT PATHS ARE THAT LEAD TO A PUBLIC WAY ONCE A | | | PERSON LEAVES THE OFFICE DOOR. | | | | | | IT IS UNDERSTOOD THAT THIS IS A CONSTRUCTION SITE, | | | HOWEVER, ONCE OCCUPIED AND PER NFPA 101 AND 241, TWO ( | | | 2) CLEAR AND PROTECTED EXIT PATHS ARE REQUIRED THAT | | | LEAD TO A PUBLIC WAY. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THETHE TWO (2) | | | EXIT PATHS AND DIMENSIONS TO A PUBLIC WAY. | | | | | | | | | 2) THERE ARE SEVERAL INDICATIONS OF STORAGE WITHIN THE | | | PROVIDED FLOOR PLAN SHEETS. | | | | | | PLEASE IDENTIFY WHAT THIS STORAGE MATERIAL IS, HOW IT | | | WILL BE STORED(PALLETS/PLASTIC WRAP. ETC) AND HOW HIGH. | | | | | | THESE AREAS MAY RESTRICT/IMPEDE THE PATH OF EXIT/EGRESS | | | PER # 1 ABOVE IF INVLOVED IN FIRE. | | | | | | ADDITIONAL PROVIDE A STATEMENT IS THESE AREAS WILL BE | | | INCLUDED WITH THE FIRE SPRINKLER PROTECTION? | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-07-19 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-07-12 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-07-07 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-28 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2023-07-17 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2023-07-17 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-03 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-07-03 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-07-17 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-07-17 |
Time |
08:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-06-30 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-06-30 |
Time |
11:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-07-19 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-07-19 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-06-28 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-06-28 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2023-06-28 15:04:13 | SIGNATURE REVIEW: | | | | | | 1- ALL DRAWINGS NEED TO BE SIGNED AND SEALED WITH | | | LICENSED DESIGN PROFESSIONAL ORIGINAL SEAL/SIGNATURE AS | | | REQUIRED BY CHAPTER 481 F.S. AND CHAPTER 471 F.S. WHEN | | | SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS. | | | (COPIES OF SIGNATURES ARE NOT ALLOWED. NEED ORIGINALS) | | | | | | NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH VERIFIABLE | | | DIGITAL SIGNATURE | | | | | | ARCHITECTS | | | 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | ENGINEERS | | | 61G15-23.004. F.A.C. PROCEDURES FOR DIGITALLY SIGNING | | | AND SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
|
|