Plan Review Details - Permit 23061296
| Plan Review Stops For Permit 23061296 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-07-21 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-07-21 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
cseifer |
Date |
2023-07-05 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
sberglun |
Date |
2023-07-05 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2023-07-05 14:02:39 | 1) CLEMATIS ST HAS A 60??? OF ROW. YOUR DIMENSIONS AS | | | SHOWN (54??? AND 13??? OF PASSABLE SIDEWALK) DON???T | | | ADD UP TO 60???. PLEASE ADD THE ROW LINES AND PROPER | | | DIMENSIONS, TO PROVIDE THE ACCESSIBLE ROUTE FOR | | | PEDESTRIANS. | | | 2) I DIDN???T SEE ANY SPECIFICATIONS OR DESCRIPTION OF | | | THE TYPE OF FENCE, AND WHERE THE GATES WILL BE LOCATED. | | | WE ALSO WANT TO SEE HOW THE GATES WILL SWING TO ALLOW | | | FOR FUEL AND MATERIAL DELIVERY. | | | SUZANNE BERGLUND | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-25 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-06 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-24 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-07-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-07-24 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-06-30 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
cibaven |
Date |
2023-07-14 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
2023-07-14 |
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy