Plan Review Details - Permit 23061217
Plan Review Stops For Permit 23061217
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-07-25 Cont ID  
Sent By dbattles Date 2023-07-25 Time 14:20 Rev Time 0.00
Received By dbattles Date 2023-07-25 Time 14:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-07-25 Cont ID  
Sent By pvalenti Date 2023-07-25 Time 07:58 Rev Time 0.00
Received By pvalenti Date 2023-07-25 Time 07:58 Sent To  
Notes
2023-07-25 08:08:19BUILDING REVIEW APPROVAL PENDING APPROVAL OF SIGNATURE
 REVIEW.
  
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 PLAN PAGE S-1 APPEARS TO HAVE BEEN ALTERED WITHOUT AN
 UPDATED 3RD PARTY VERIFIABLE SIGNATURE BY THE DESIGN
 PROFESSIONAL.
  
 1. DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE. A SCAN OF A WET SEAL AND
 SIGNATURE OR DIGITAL SIGNATURE IS NOT CONSIDERED A
 VALID DIGITAL SIGNATURE.
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C.
  
 2. SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE.
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT.
 481, F.S. & 61G1.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-19 Cont ID  
Sent By rmcdouga Date 2023-07-19 Time 09:10 Rev Time 0.00
Received By rmcdouga Date 2023-07-19 Time 09:10 Sent To  
Notes
2023-07-19 09:10:28PLAN REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 THE BOTTOM EXTENSION OF THE HANDRAIL IS HORIZONTAL AND
 IT IS REQUIRED TO BE SLOPED TO COMPLY WITH FBC-
 ACCESSIBILITY 505.10.3 BOTTOM EXTENSION AT STAIRS. AT
 THE BOTTOM OF A STAIR FLIGHT, HANDRAILS SHALL EXTEND AT
 THE SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DISTANCE
 AT LEAST EQUAL TO ONE TREAD DEPTH BEYOND THE LAST RISER
 NOSING. EXTENSION SHALL RETURN TO A WALL, GUARD, OR THE
 LANDING SURFACE, OR SHALL BE CONTINUOUS TO THE HANDRAIL
 OF AN ADJACENT STAIR FLIGHT.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By pleduc Date 2023-07-18 Time   Rev Time 0.00
Received By pleduc Date 2023-06-27 Time 13:31 Sent To  
Notes
2023-06-28 14:18:26FIRE RECEIVED AN EMAIL ON 7/18/23 FROM THE APPLICANT
 PROVIDED A SITE PLAN PER THE COMMENT BELOW.
  
 THE PERMIT LIBRARIAN ADDED THEM TO THE SUBMITTAL.
  
 FIRE CHANGED THE FAIL TO PASS.
  
 PML
 7/18/23
  
  
  
 *******************************************************
 *******************************************************
 *********************************
  
  
 THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF NEW STAIR STRUCTURE,
 HOWEVER, THERE IS NO SITE PLAN INDICATING THE LOCATION
 OF THE PROPOSED.
  
 PER NFPA 1
  
 1.7.12 PLANS AND SPECIFICATIONS.
  
 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE
 PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH
 APPLICABLE CODES AND STANDARDS
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE A DETAILED SITE
 PLAN.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-07-25 Cont ID  
Sent By dbattles Date 2023-07-25 Time 14:21 Rev Time 0.00
Received By dbattles Date 2023-07-25 Time 14:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-25 Cont ID  
Sent By pvalenti Date 2023-07-25 Time 08:25 Rev Time 0.00
Received By pvalenti Date 2023-07-21 Time 15:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-19 Cont ID  
Sent By rmcdouga Date 2023-07-19 Time 09:10 Rev Time 0.00
Received By rmcdouga Date 2023-06-27 Time 11:33 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-25 Cont ID  
Sent By dbattles Date 2023-07-25 Time 14:20 Rev Time 0.00
Received By dbattles Date 2023-07-25 Time 14:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-07-25 Cont ID  
Sent By pvalenti Date 2023-07-25 Time 08:24 Rev Time 0.00
Received By pvalenti Date 2023-07-25 Time 08:24 Sent To  
Notes
2023-07-25 08:25:42SIGNATURE REVIEW DENIED:
  
 PLAN SHEET S-1 NEEDS TO HAVE A 3RD PARTY VERIFIABLE
 DESIGN PROFESSIONAL SIGNATURE.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-07-19 Cont ID  
Sent By rmcdouga Date 2023-07-19 Time 09:10 Rev Time 0.00
Received By rmcdouga Date 2023-07-19 Time 09:10 Sent To  
Notes
2023-07-19 09:14:07THE ENGINEER'S DIGITAL SIGNATURE WAS VALID 11/10/2021
 TO 11/10/2022.

Review Stop Z ZONING
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By gvolcy Date 2023-07-18 Time 15:07 Rev Time 0.00
Received By avolcy Date 2023-07-18 Time 15:07 Sent To  
Notes
***NONE***