Plan Review Details - Permit 23061137
Plan Review Stops For Permit 23061137
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status   Date   Cont ID  
Sent By rmcdouga Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-07-14 Cont ID  
Sent By jleahy Date 2023-07-14 Time 09:51 Rev Time 0.00
Received By jleahy Date 2023-07-14 Time 09:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-07-17 Cont ID  
Sent By pleduc Date 2023-07-17 Time   Rev Time 0.00
Received By pleduc Date 2023-07-06 Time 15:10 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-07-18 Cont ID  
Sent By ccole Date 2023-07-18 Time 12:12 Rev Time 0.00
Received By ccole Date 2023-07-18 Time 10:31 Sent To  
Notes
2023-07-18 12:13:141ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 23061137
 7/1/23
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P.508: INDICATE HOW COMBUSTION AIR WILL BE
 PROVIDED FOR THE NEW GAS DRYERS AND WATER HEATER IN THE
 LAUNDRY ROOM- SEC. 304.1 FBC FG.
  
 2) P.508 & P.805: PROVIDE A VENTING PLAN FOR THE NEW
 WATER HEATER. SHOW THE TYPE AND SIZE OF VENT, VENT RUN
 AND TERMINATION LOCATION- SEC. 503.1 & 624.1 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By aoliver Date 2023-06-30 Time 15:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-24 Cont ID  
Sent By hmoser Date 2023-07-24 Time 08:36 Rev Time 0.00
Received By hmoser Date 2023-07-24 Time 07:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-07-18 Cont ID  
Sent By ccole Date 2023-07-18 Time 12:13 Rev Time 0.00
Received By ccole Date 2023-07-17 Time 17:38 Sent To  
Notes
2023-07-18 12:14:081ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23061137
 7/18/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) P.100, P.508A, P.715: THE NEW WASHING MACHINES SHALL
 DISCHARGE THROUGH INTERCEPTORS EQUIPPED WITH WIRE
 BASKETS OR SIMILAR DEVICES, REMOVABLE FOR CLEANING,
 THAT PREVENTS PASSAGE INTO THE DRAINAGE SYSTEM OF
 SOLIDS 1/2 INCH OR LARGER IN SIZE, STRING, RAGS,
 BUTTONS OR OTHER MATERIALS DETRIMENTAL TO THE PUBLIC
 SEWAGE SYSTEM- SEC. 1003.6 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-07-14 Cont ID  
Sent By jleahy Date 2023-07-14 Time 09:52 Rev Time 0.00
Received By jleahy Date 2023-07-14 Time 09:52 Sent To  
Notes
2023-07-14 09:54:00FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGES C-01 THROUGH C-13 SIGNATURES ARE NOT DIGITALLY
 VERIFIABLE.

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By ckimmerl Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved