Plan Review Details - Permit 23061137
| Plan Review Stops For Permit 23061137 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-14 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-14 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-06 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-18 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-18 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2023-07-18 12:13:14 | 1ST REVIEW FBC-2020 FUEL GAS | | | PERMIT- 23061137 | | | 7/1/23 | | | | | | CODES IN EFFECT: | | | FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P.508: INDICATE HOW COMBUSTION AIR WILL BE | | | PROVIDED FOR THE NEW GAS DRYERS AND WATER HEATER IN THE | | | LAUNDRY ROOM- SEC. 304.1 FBC FG. | | | | | | 2) P.508 & P.805: PROVIDE A VENTING PLAN FOR THE NEW | | | WATER HEATER. SHOW THE TYPE AND SIZE OF VENT, VENT RUN | | | AND TERMINATION LOCATION- SEC. 503.1 & 624.1 FBC FG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-30 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-24 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-07-24 |
Time |
07:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-18 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-17 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2023-07-18 12:14:08 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 23061137 | | | 7/18/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) P.100, P.508A, P.715: THE NEW WASHING MACHINES SHALL | | | DISCHARGE THROUGH INTERCEPTORS EQUIPPED WITH WIRE | | | BASKETS OR SIMILAR DEVICES, REMOVABLE FOR CLEANING, | | | THAT PREVENTS PASSAGE INTO THE DRAINAGE SYSTEM OF | | | SOLIDS 1/2 INCH OR LARGER IN SIZE, STRING, RAGS, | | | BUTTONS OR OTHER MATERIALS DETRIMENTAL TO THE PUBLIC | | | SEWAGE SYSTEM- SEC. 1003.6 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-14 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-14 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2023-07-14 09:54:00 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGES C-01 THROUGH C-13 SIGNATURES ARE NOT DIGITALLY | | | VERIFIABLE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
ckimmerl |
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |