Plan Review Details - Permit 23061131
| Plan Review Stops For Permit 23061131 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-07-13 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-07-13 |
Time |
15:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-06-27 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-06-27 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2023-06-27 16:15:14 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE DISCONNECTING MEANS FOR A/C EQUIPMENT PER | | | NEC 440.14 OR IRC E4101.5 | | | DISCONNECTING MEANS IS REQUIRED TO BE LOCATED ???WITHIN | | | SIGHT FROM AND READILY ACCESSIBLE??? FROM THE | | | AIR-CONDITIONING EQUIPMENT. | | | | | | 2. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11 | | | THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION | | | FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS | | | APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING | | | OCCUPANCIES | | | | | | 3. THE PAGE WHERE THE LOAD CALCULATION AND ELECTRICAL | | | SCOPE OF WORK ARE LOACTED IS NOT CLEAR AND CANNOT BE | | | READ. PLEASE SUBMIT CLEAR, READABLE PLANS. FBC 107.2 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN P. PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER/ INSPECTOR | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-13 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-06-26 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-13 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-07-13 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-13 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-07-13 |
Time |
13:08 |
Sent To |
|
|
| Notes |
|
|
|