Plan Review Details - Permit 23060825
Plan Review Stops For Permit 23060825
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2023-07-13 Cont ID  
Sent By cpuell Date 2023-07-13 Time 13:33 Rev Time 0.00
Received By cpuell Date 2023-07-13 Time 13:33 Sent To  
Notes
2023-07-13 13:33:51PAPA GAVE PRELIMINARY LETTER PCN IS 74434327910000604
 UPDATED PERMIT

Review Stop AD ADDRESSING
Rev No 2 Status P Date 2023-06-30 Cont ID  
Sent By cpuell Date 2023-06-30 Time 11:59 Rev Time 0.00
Received By cpuell Date 2023-06-30 Time 11:59 Sent To  
Notes
2023-06-30 12:01:52PER RBROWN ADDRESS ASSIGNED UNDER PCN OF THE PRIMARY
 ADDRESS 200 ARKONA CT, DUE TO PAPA NOT BEING ABLE TO
 ASSING A PCN UNTIL 2024. C/O HOLD PUT ON THE PERMIT, TO
 UPDATE THE PARCEL AND OWNER ONCE THAT INFORMATION
 BECOME AVAILABLE. PLEASE REACH OUT TO
 [email protected] OR CALL 561-805-6659 ONCE THE PCN
 BECOME AVAILABLE

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-06-22 Cont ID  
Sent By cpuell Date 2023-06-22 Time 08:39 Rev Time 0.00
Received By cpuell Date 2023-06-22 Time 08:39 Sent To  
Notes
2023-06-22 08:42:35THIS ADDRESS HAS NOT BEEN ESTABLISHED AS THE UNIT HAS
 NOT BEEN ASSIGNED A SEPARATE PCN. BUILDING OWNERS
 REPRESENTATIVES NEED TO GET REQUEST PCN FROM PALM BEACH
 COUNTY, AS THESE UNITS ARE NOT RENTALS AND NEED THEIR
 OWN PCN. PLEASE CONTACT [email protected] OR CALL
 561-805-6659 TO DISCUSS ADDRESSING ISSUES.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2023-07-05 Cont ID  
Sent By jwitmer Date 2023-07-05 Time 12:12 Rev Time 0.00
Received By jwitmer Date 2023-07-05 Time 12:12 Sent To  
Notes
2023-07-05 13:12:40NO ASBESTOS 1ST TENANT BUILD OUT, NEW CONSTRUCTION. J
 WITMER

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-07-25 Cont ID  
Sent By jwitmer Date 2023-07-25 Time 09:24 Rev Time 0.00
Received By jwitmer Date 2023-07-25 Time 08:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-05 Cont ID  
Sent By jwitmer Date 2023-07-05 Time 13:21 Rev Time 0.00
Received By jwitmer Date 2023-07-05 Time 12:13 Sent To  
Notes
2023-07-05 13:21:56WEST PALM BEACH DEVELOPMENT SERVICES
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 23060825
 ADD: 200 ARKONA CT. # 604
 CONT: AMERICAN CONSTRUCTION SERVICES INC.
 TEL: 954-590-8005
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE:
 ACTION: DENIED
  
 1) FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR
 TILE, STONE, MARBLE, FLOORING ALL NEED TO HAVE HAD THE
 SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE
 FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS LISTED
 UNDER EACH OF THE STANDARDS FOR A 6-INCH OR 8 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 1A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 1B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 1C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. (TILE
 & MARBLE) INSULATION INSTALLED BETWEEN A FINISHED FLOOR
 AND SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
 2) SHEET A-2.1 DOOR SCHEDULE DOOR 101 IS LISTED AS A
 2???-8??? OR 32??? DOOR. FAIR HOUSING INTERIOR DOORWAYS
 (USEABLE DOORS) ANSI 4.13. WHERE THIS SECTION REQUIRES
 A MINIMUM CLEAR WIDTH OF 32 INCHES OR A 34-INCH DOOR
 MINIMUM. THE MINIMUM SIZE OF A SWING DOORS IS MEASURED
 CLEAR OPENING OF THE DOORWAY WITH THE SWINGING DOORS
 SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE
 STOP, WITH THE DOOR OPEN 90 DEGREES.
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-06-25 Cont ID  
Sent By jcooley Date 2023-06-22 Time 17:36 Rev Time 0.00
Received By jcooley Date 2023-06-25 Time 18:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-07-19 Cont ID  
Sent By pleduc Date 2023-07-19 Time   Rev Time 0.00
Received By pleduc Date 2023-07-19 Time 13:22 Sent To  
Notes
2023-07-19 13:23:08FIRE PROVISO:
  
 ANY REMOVAL OR CONSTRUCTION OF WALLS/CEILINGS REQUIRES
 AND EVALUATION OF THE FIRE SPRINKLER AND FIRE ALARM
 SYSTEMS FOR CODE COMPLIANT COVERAGE
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-06-23 Cont ID  
Sent By pleduc Date 2023-06-23 Time   Rev Time 0.00
Received By pleduc Date 2023-06-23 Time 10:24 Sent To  
Notes
2023-06-23 10:37:28FIRE PROVISO:
  
 ANY REMOVAL OR CONSTRUCTION OF WALLS/CEILINGS REQUIRES
 AND EVALUATION OF THE FIRE SPRINKLER AND FIRE ALARM
 SYSTEMS FOR CODE COMPLIANT COVERAGE
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status P Date 2023-07-25 Cont ID  
Sent By jwitmer Date 2023-07-25 Time 09:27 Rev Time 0.00
Received By jwitmer Date 2023-07-18 Time 08:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-10 Cont ID  
Sent By hmoser Date 2023-07-10 Time 08:13 Rev Time 0.00
Received By hmoser Date 2023-06-20 Time 13:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-10 Cont ID  
Sent By hmoser Date 2023-07-10 Time 08:12 Rev Time 0.00
Received By hmoser Date 2023-07-10 Time 07:40 Sent To  
Notes
2023-07-10 08:12:26PASS PROVISO
 REFER TO SECTION 602.2.1 MATERIALS WITHIN PLENUMS.
 2020 FBC (M) HM.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-07-20 Cont ID  
Sent By ccole Date 2023-07-20 Time 15:45 Rev Time 0.00
Received By ccole Date 2023-07-20 Time 15:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-06-23 Cont ID  
Sent By ccole Date 2023-06-23 Time 11:29 Rev Time 0.00
Received By ccole Date 2023-06-23 Time 09:48 Sent To  
Notes
2023-06-23 11:32:35 
 1ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23060824
 3/21/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 FHDA- FAIR HOUSING DESIGN ACT MANUAL
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) FAIR HOUSING ACT COMPLIANCE: THE CONDOMINIUMS AT 200
 ARKONA CT. ARE SUBJECT TO COMPLIANCE WITH FAIR HOUSING
 ACCESSIBILITY GUIDELINES WHICH CAME INTO EFFECT FOR
 MULTIFAMILY HOUSING BUILT FOR FIRST OCCUPANCY AFTER
 MARCH 13, 1991. THE SUBMITTED PLAN SHOWING THE NEW
 ROLL-IN SHOWER IN THE MASTER BATH APPEARS TO BE
 NON-COMPLIANT WITH THE GUIDELINES BECAUSE THERE IS A
 LAVATORY SINK INSIDE THE STALL WHERE GRAB BARS WOULD BE
 REQUIRED- PAGE 6.13 FHDA MANUAL. THE SHOWER SHALL BE
 RECONFIGURED IN ACCORDANCE WITH COMMENTS #2 & 2A BELOW.
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS AND COMMENTS #2 &
 2A, THE OWNER AND DESIGNER OF RECORD FOR THE PROPOSED
 PROJECT MAY PROVIDE A SIGNED AND NOTARIZED AFFIDAVIT
 WHICH WOULD INDICATE ACKNOWLEDGEMENT THAT THE PROPOSED
 DESIGN DOES NOT MEET THE REQUIREMENTS OF THE FAIR
 HOUSING ACCESSIBILITY GUIDELINES, BUT WILL ALSO REQUIRE
 THE OWNER TO AGREE TO REVERT THE UNIT BACK TO
 COMPLIANCE AT TIME OF SALE IF REQUESTED BY THE BUYER.
 IF THIS OPTION IS CHOSEN, PLEASE SEND AN EMAIL TO
 [email protected] AND I WILL SEND A COPY OF THE FAIR
 HOUSING AFFIDAVIT.
  
 2) SHEETS A-2.1, A-5.1, & P-1: PLEASE REMOVE THE
 LAVATORY SINK AND PROVIDE GRAB REINFORCEMENT DETAILS IN
 COMPLIANCE WITH PAGES 6.12, 6.13 FDHA MANUAL. THE
 ELEVATION DETAILS ON A-5.1 CAN BE MODIFIED TO SHOW THE
 CORRECT GRAB BAR BACKING LOCATION LENGTHS AND HEIGHTS.
  
 2A) SHOW THE MOUNTING HEIGHT AND DIMENSIONS OF THE
 SHOWER SEAT- PAGE 6.13.
  
 3) P-1: RELOCATING THE SHOWER DRAIN OUTLET MAY REQUIRE
 THE FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE
 REINFORCING STEEL OR POST STRESSED FLOOR TENDONS.
 PLEASE PLACE A NOTE ON THE PLANS TO VERIFY COMPLIANCE
 WILL BE MET- SEC. 107.2.1 WPB.
  
 4) P-1: NEW DRAIN PIPE PENETRATIONS OF THE EXISTING
 SLAB WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR
 SPACE AROUND THE PIPING. PROVIDE UL TESTED AND APPROVED
 FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SEC. 315.1
 FBC P AND SEC. 714.4.1.2 FBC B.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-07-25 Cont ID  
Sent By jwitmer Date 2023-07-25 Time 09:27 Rev Time 0.00
Received By jwitmer Date 2023-07-25 Time 09:20 Sent To  
Notes
2023-07-20 15:47:14PLUMBING PLAN SIGNATURE PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-05 Cont ID  
Sent By lbond Date 2023-07-05 Time 11:46 Rev Time 0.00
Received By lbond Date 2023-07-05 Time 11:46 Sent To  
Notes
2023-06-23 12:30:39PLUMBING SIGNATURE PASSED.