Plan Review Details - Permit 23060618
Plan Review Stops For Permit 23060618
Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-06-27 Cont ID  
Sent By cpuell Date 2023-06-27 Time 10:00 Rev Time 0.00
Received By cpuell Date 2023-06-27 Time 10:00 Sent To  
Notes
2023-06-27 10:12:40WORK TO BE DONE ON THE SOUTH BUILDING, THE NORTH
 BUILDING HAS A HALF ADDRESS WHICH WILL NEED TO BE
 READDRESSED, PLEASE HAVE THE OWNER CONTACT
 [email protected] OR CALL 561-805-6659 TO READDRESS
 THE HALF ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-07 Cont ID  
Sent By lbond Date 2023-07-07 Time 11:19 Rev Time 0.00
Received By lbond Date 2023-07-07 Time 11:19 Sent To  
Notes
2023-07-07 11:21:39FBC 107.2.1
  
 PROVIDE NOA OR FPC PRODUCT APPROVAL FOR NEW IMPACT
 WINDOWS AND DOORS AND UPLOAD TO SUPPORTING DOCUMENTS.
 ALSO PLEAE MAKE SURE YOUR ADDITION IS NOT ENCROACHING
 ON ALLOWED SIDE BUILIDNG SETBACKS-
  
 PROVIDE RECENT SURVEY WITH ALLOWED SET BACK AND DRAW TO
 SCALE ADDITION PROPOSED WITH SETBACK TO MECHANICAL
 EQUIPEMENT AND BUILIDNG.
  
 IF ANY QUESTIONS OR CONCERNS:
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-06-28 Cont ID  
Sent By jcooley Date 2023-06-28 Time 17:49 Rev Time 0.00
Received By jcooley Date 2023-06-28 Time 17:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-17 Cont ID  
Sent By cmontell Date 2023-07-17 Time 12:43 Rev Time 0.00
Received By cmontell Date 2023-07-17 Time 12:43 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-07-07 Cont ID  
Sent By lbond Date 2023-07-07 Time 11:10 Rev Time 0.00
Received By lbond Date 2023-07-07 Time 11:10 Sent To  
Notes
2023-07-07 11:12:01BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23060618
  
 REVIEWED: 7.7.2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]
  
  
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-17 Cont ID  
Sent By cmontell Date 2023-07-17 Time 12:43 Rev Time 0.00
Received By cmontell Date 2023-07-17 Time 12:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-07-01 Cont ID  
Sent By rwbrown Date 2023-07-01 Time 11:01 Rev Time 0.00
Received By rwbrown Date 2023-07-01 Time 11:01 Sent To  
Notes
2023-07-01 11:08:131ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FRC TABLE P3201.7 - IN TWO PLACES ON PAGE P1,
 THE PLAN VIEW AND THE ISOMETRIC, YOU'VE LABELED THE
 FIXTURE DRAIN SIZE FOR THE WATER CLOSET AT 2". PLEASE
 CORRECT IT TO 3".
  
 2. 2017 WPB AMENDS 107.2.1 - THE ISOMETRIC AND THE PLAN
 VIEW DO NOT MATCH. ONE SHOW A LINEAR CONFIGURATION WITH
 A VENT AT THE END OF THE RUN AND THE OTHER SHOWS A
 DIFFERENT ROUTE WITH AN INDIVIDUAL VENT ON THE SHOWER
 FIXTURE DRAIN. PLEASE ADDRESS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2023-07-07 Cont ID  
Sent By lbond Date 2023-07-07 Time 11:18 Rev Time 0.00
Received By lbond Date 2023-07-07 Time 11:18 Sent To  
Notes
2023-07-07 12:04:52THIS PROPOSED ADDITION IS NOT ALLOWED AS LOCATED
 NEEDS A VARIANCE

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-07-07 Cont ID  
Sent By lbond Date 2023-07-07 Time 11:10 Rev Time 0.00
Received By lbond Date 2023-07-07 Time 12:10 Sent To  
Notes
2023-07-07 12:09:41REFER TO ZONING COMMENTS
 CAN'T APPROVED THE SIGNATURE AT THIS TIME

Review Stop Z ZONING
Rev No 1 Status F Date 2023-07-07 Cont ID  
Sent By lgelman Date 2023-07-07 Time 09:00 Rev Time 0.00
Received By lngelman Date 2023-07-07 Time 11:44 Sent To  
Notes
2023-07-07 09:00:25LOCATION OF ADDITION IS LOCATED WITHIN FRONT YARD
 SETBACK AND REQUIRES A VARIANCE TO ENCROACH WITHIN THE
 25 FOOT FRONT YARD. CONTACT [email protected] TO OBTAIN
 APPLICATION FOR VARIANCE.
  
 SETBACKS ARE TO BE MEASURED FROM THE PROPERTY LINE TO
 THE CLOSEST POINT OF THE STRUCTURE. THE SETBACK FOR THE
 ADDITION AND NEW CONCRETE SLABS SHOULD BE MEASURED FROM
 THE SOUTHEASTERN POINT OF THE STRUCTURE TO THE SOUTHERN
 AND EASTERN PROPERTY LINE.
  
 PLANS ARE NOT TO SCALE; PLANS SHOW THE LOCATION OF
 EXISITING HOME TO BE VERY CLOSE TO THE EASTERN PROPERTY
 LINE. REVISE PLANS TO BE ACCURATE IN TERMS OF LOCATION
 AND INCLUDE BUILDING SETBACKS FROM BOUNDARY LINES.
  
 SHOW FLOORPLAN OF EXISTING HOME; INDICATE HOW MANY
 BEDROOMS ARE EXISTING AND PROPOSED. ADDITIONAL BEDROOMS
 MAY AFFECT PARKING REQUIREMENTS.
  
 SEPARATE PERMIT REQUIRED FOR:
 FENCE/WALL, AWNINGS, SIGNS, PARKING LOT, GENERATOR,
 MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE,
 IRRIGATION, LANDSCAPE, OTHER.
  
 ******REVIEWED BY*****
 LINDSEY GELMAN
 561-822-1275
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved