Plan Review Details - Permit 23060409
Plan Review Stops For Permit 23060409
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-07-17 Cont ID  
Sent By jwitmer Date 2023-07-17 Time 15:18 Rev Time 0.00
Received By jwitmer Date 2023-07-17 Time 15:08 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-06-28 Cont ID  
Sent By jwitmer Date 2023-06-28 Time 13:52 Rev Time 0.00
Received By jwitmer Date 2023-06-28 Time 13:01 Sent To  
Notes
2023-06-28 13:52:21TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By jwitmer Date 2023-07-18 Time 15:37 Rev Time 0.00
Received By jwitmer Date 2023-07-17 Time 15:18 Sent To  
Notes
2023-07-17 15:37:00WEST PALM BEACH DEVELOPMENT SERVICES
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 23060409
 ADD: 622 N FLAGLER DR # 503
 CONT: LIVINGTON BUILDERS, INC.
 TEL: 561-833-3242
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. JULY 17TH/2023
 ACTION:PASSED PROFLEX SUPER SIM 90
  
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-06-28 Cont ID  
Sent By jwitmer Date 2023-06-28 Time 13:51 Rev Time 0.00
Received By jwitmer Date 2023-06-28 Time 13:00 Sent To  
Notes
2023-06-28 13:51:34WEST PALM BEACH DEVELOPMENT SERVICES
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 23060409
 ADD: 622 N FLAGLER DR # 503
 CONT: LIVINGTON BUILDERS, INC.
 TEL: 561-833-3242
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. JUNE 28TH/2023
 ACTION: DENIED
  
 1) SHEET A101A THE PROPOSED FLOOR PLAN SHOWS THE
 KITCHEN ISLAND BEING RECONFIGURED. THERE IS A NOTE IN
 THE UPPER RIGHT-HAND CORNER, POST TENSION STRUCTURE
 WARNING DO NOT DRILL OR CUT, OR CORE DRILL SLAB OR
 CEILING. HOW WILL THE KITCHEN ISLAND PLUMBING BE
 RELOCATED WITHOUT CORE DRILLING THE SLAB?
  
 POST TENSION SLAB/ NEW HOLES. THE PLAN IS SILENT AS IF
 THE LOCATION OF THE EXISTING KITCHEN ISLAND DRAIN IS
 GOING TO BE REUSED IN THE SAME LOCATION. IF NOT, THEN
 THE FLOOR SLAB WILL NEED TO BE X-RAYED TO FIND THE POST
 TENSION CHORD LOCATIONS. 107.2.1.2. ADDITIONAL
 INFORMATION IS REQUIRED.
  
 2) THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL
 ASSEMBLIES). IF A NEW FLOOR PENETRATION IS MADE FOR THE
 FUTURE SHOWER DRAIN, THEN YOU NEED TO SHOW COMPLIANCE
 WITH THE 2020 FBC-B SECTION 714.5.1.2.
 THROUGH-PENETRATIONS FIRESTOP SYSTEMS (HORIZONTAL
 ASSEMBLIES). THROUGH PENETRATIONS SHALL BE PROTECTED BY
 A THROUGH PENETRATION FIRESTOP SYSTEM INSTALLED IN
 ACCORDANCE WITH ASTM E814 OR UL 1479. THE SYSTEM SHALL
 HAVE AN F RATING / T RATING OF NOT LESS THAN 1 HOUR BUT
 NOT LESS THAN THE REQUIRED RATING OF THE FLOOR
 PENETRATED.
  
 3) PLEASE NOTE THE PLANS ARE REFENCING CODE SECTIONS
 THAT ARE BEING TAKEN FROM THE RESIDENTIAL CODE (1 & 2
 FAMILY CODE, NOT THE 2020 FBC-BUILDING CODE, R2
 OCCUPANCIES, APARTMENTS AND CONDOMINIUMS, 2020
 FBC-BUILDING SECTION 310.4.
  
 4) THE FLOOR PLAN 101C INDICATES INTERIOR ROOMS TO
 RECEIVE TL-2S PORCELAIN TILE. FLOOR INSULATION/
 UNDERLAYMENT (FBC-B 2020) FOR TILE, STONE, MARBLE,
 FLOORING ALL NEED TO HAVE HAD THE SOUND UNDERLAYMENT
 TESTED FLOOR ASSEMBLIES TO THE FOLLOWING STANDARDS AND
 MEET THE QUALIFICATIONS LISTED UNDER EACH OF THE
 STANDARDS FOR A 6-INCH CONCRETE FLOOR ASSEMBLY/ NO
 DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 4A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 4B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 4C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. (TILE
 & MARBLE) INSULATION INSTALLED BETWEEN A FINISHED FLOOR
 AND SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 5) THE FLOOR PLAN 101C INDICATES EXTERIOR BALCONIES ARE
 TO RECEIVE SLIP RESISTANT TILE. PLEASE BE AWARE THE
 BALCONIES IN MOST CONDOMINIUM DOCUMENTS ARE BEYOND THE
 WALL LINE OF THE CONDO OWNERSHIP, PLEASE PROVIDE
 WRITTEN PERMISSION FROM THE BOARD OF DIRECTORS
 APPROVING THE INSTALLATION OF TILE ON BALCONIES. THIS
 LETTER TO BE NOTARIZED.
  
 6) FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR
 TILE, STONE, MARBLE FLOORING ALL NEED TO HAVE HAD THE
 SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE
 FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS LISTED
 UNDER EACH OF THE STANDARDS FOR A 6-INCH CONCRETE FLOOR
 ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 6A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 6B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 6C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. (TILE
 & MARBLE) INSULATION INSTALLED BETWEEN A FINISHED FLOOR
 AND SOLID DECKING WITHOUT INTERVENING AIRSPACE SHALL BE
 ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
 200.
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 7) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By rperdomo Date 2023-07-18 Time 16:52 Rev Time 0.00
Received By rperdomo Date 2023-07-18 Time 16:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-06-26 Cont ID  
Sent By rperdomo Date 2023-06-26 Time 08:36 Rev Time 0.00
Received By rperdomo Date 2023-06-23 Time 16:20 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-07-12 Cont ID  
Sent By pleduc Date 2023-07-12 Time   Rev Time 0.00
Received By pleduc Date 2023-07-12 Time 15:32 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-06-13 Cont ID  
Sent By pleduc Date 2023-06-13 Time   Rev Time 0.00
Received By pleduc Date 2023-06-13 Time 10:18 Sent To  
Notes
2023-06-13 10:26:05THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF INSTALLING NEW CARPET IS
 SOME ROOMS, HOWEVER, THERE IS NO INDICATION OF THE
 REPLACEMENT CARPET PRODUCT NAME NOR A SPEC SHEET.
  
 THERE ARE NO DETAILS ON THE FLOOR FINNISH PLAN.
  
 CARPET IS MANUFACTURED AROUND THE WORLD AND NOT ALL ARE
 TESTED AND MEETING LISTED AND NFPA STANDARDS.
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7* INTERIOR FLOOR FINISH TESTING AND
 CLASSIFICATION.
  
 10.2.7.1* CARPET AND CARPET LIKE INTERIOR FLOOR
 FINISHES SHALL
 COMPLY WITH ASTM D 2859, STANDARD TEST METHOD FOR
 IGNITION
 CHARACTERISTICS OF FINISHED TEXTILE FLOOR COVERING
 MATERIALS.
  
 10.2.7.4 INTERIOR FLOOR FINISHES SHALL BE GROUPED IN
 THE CLASSES SPECIFIED
 IN 10.2.7.4.1 AND 10.2.7.4.2 IN ACCORDANCE WITH THE
 CRITICAL RADIANT FLUX
 REQUIREMENTS.
 10.2.7.4.1 CLASS I INTERIOR FLOOR FINISH. CLASS I
 INTERIOR FLOOR FINISH
 SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN
 0.45 W/CM2, AS DETERMINED
 BY THE TEST DESCRIBED IN 10.2.7.3.
 10.2.7.4.2 CLASS II INTERIOR FLOOR FINISH. CLASS II
 INTERIOR FLOOR FINISH
 SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN
 0.22 W/CM2, BUT LESS
 THAN 0.45 W/CM2, AS DETERMINED BY THE TEST DESCRIBED IN
 10.2.7.3.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE CARPET
 PRODUCT NAME AND THE PRODUCT SPEC SHEETS INDICATING THE
 FIRE BEHAVIOR RATING.
  
  
  
 2) THERE ARE INDICATIONS OF WALLS BEING REMOVED AND NEW
 WALL CONSTRUCTION.
  
 FIRE PROVISO:
  
 ANY REMOVAL OR CONSTRUCTION OF WALLS/CEILINGS REQUIRES
 AND EVALUATION OF THE FIRE SPRINKLER AND FIRE ALARM
 SYSTEMS FOR CODE COMPLIANT COVERAGE
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PLEASE ENSURE APPLICABLE PROTECTION AND PROVIDE A NOTE
 OF ACKNOWLEDGMENT ON THE FLOOR PLAN.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By ccole Date 2023-07-18 Time 13:32 Rev Time 0.00
Received By ccole Date 2023-07-18 Time 12:21 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-06-16 Cont ID  
Sent By ccole Date 2023-06-16 Time 16:10 Rev Time 0.00
Received By ccole Date 2023-06-16 Time 15:05 Sent To  
Notes
2023-06-16 16:16:591ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 23060409
 6/16/23
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-1.01A: PLEASE CLARIFY THE SCOPE OF GAS WORK-
 SEC. 107.2.1 WPB. THERE IS A NOTE ON THE PLAN
 REFERENCING A GAS RISER WHICH IS NOT SHOWN ON THE
 PLANS. PLEASE PROVIDE THE RISER- SEC. 107.3.5.1.5 WPB.
  
 2) A-1.01A: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE
 NEW RANGE- SEC. 304.1 FBC FG. IF USING THE STANDARD
 METHOD OF INDOOR AIR PER SEC. 304.5.1 THE MINIMUM
 REQUIRED VOLUME IS 50 CU. FT. PER 1000 BTUH.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-20 Cont ID  
Sent By aoliver Date 2023-07-20 Time 09:34 Rev Time 0.00
Received By aoliver Date 2023-07-10 Time 08:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-06 Cont ID  
Sent By rmcphers Date 2023-07-06 Time 09:16 Rev Time 0.00
Received By rmcphers Date 2023-06-12 Time 12:22 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-07-17 Cont ID  
Sent By jbaker Date 2023-07-17 Time 12:30 Rev Time 0.00
Received By jbaker Date 2023-07-17 Time 12:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-03 Cont ID  
Sent By hmoser Date 2023-07-03 Time 07:55 Rev Time 0.00
Received By hmoser Date 2023-07-03 Time 07:09 Sent To  
Notes
2023-07-03 07:55:46PROVIDE MANUFACTURE SPECIFICATIONS ON
 RAINGE HOOD EXHAUST AT FIRST MECHANICAL
 INSPECTION.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By ccole Date 2023-07-18 Time 13:10 Rev Time 0.00
Received By ccole Date 2023-07-18 Time 12:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-06-16 Cont ID  
Sent By ccole Date 2023-06-16 Time 15:56 Rev Time 0.00
Received By ccole Date 2023-06-16 Time 15:05 Sent To  
Notes
2023-06-16 15:57:481ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23060409
 6/16/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-1.01A: PLEASE PROVIDE A SANITARY DRAIN AND
 VENT ISOMETRIC DRAWING FOR THE NEW ISLAND SINK- SECS.
 916.2 & 916.3 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status N Date 2023-07-19 Cont ID  
Sent By rgathrig Date 2023-07-19 Time 18:02 Rev Time 0.00
Received By rgathrig Date 2023-07-19 Time 18:02 Sent To  
Notes
2023-07-19 18:03:26CONTRACTOR CHANGED HIS MIND ABOUT USING PRIVATE
 PROVIDER
 PROVIDED LETTER
 R GATHRIGHT

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status N Date 2023-07-05 Cont ID  
Sent By rgathrig Date 2023-07-05 Time 14:35 Rev Time 0.00
Received By rgathrig Date 2023-07-05 Time 14:35 Sent To  
Notes
2023-07-05 14:50:34CONTRACTOR CHNGED HIS MIND ABOUT USING PRIVATE PROVIDER
 PP REVIEW STOP NOT REQUIRED 7/19/23 RGATHRIGHT
  
 PRIVATE PROVIDER FOR INSPECTIONS ONLY FAILED
 PERMIT APPLICATION IS MARKED TO BE PRIVATE PROVIDER,
 INSPECTIONS
 AUDIT FOR PRIVATE PROVIDER DOCUMENTS FAILED. CONTRACTOR
 DID NOT PROVIDE
 NOTICE TO BUILDING OFFICIAL, COI, OR INSPECTORS NAMES.
 F.S.553.791
  
 RICHARD GATHRIGHT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By ccole Date 2023-07-18 Time 13:32 Rev Time 0.00
Received By ccole Date 2023-07-18 Time 12:21 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-07-06 Cont ID  
Sent By rmcphers Date 2023-07-06 Time 09:14 Rev Time 0.00
Received By rmcphers Date 2023-07-06 Time 09:14 Sent To  
Notes
2023-07-06 09:16:31SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) THE PROVIDED SIGNED AND SEALED DRAWINGS DO NOT SHOW
 AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  