| Plan Review Stops For Permit 23060406 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-21 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-21 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2023-07-21 10:21:30 | FBC 107.2.1 | | | | | | BUILDING PLAN REVIEW: FAILED | | | | | | SHEET 2 | | | PROPOSED PLAN IS NOT SHOWING THE 2HR WALL IN BETWEEN | | | UNITS AS SHOWN ON OTHER SHEETS | | | PLEASE UDAPTE ACCORDINGLY | | | | | | SHEET 4 | | | POPOSED LAYOUT IS SHOWING A WINDOW IN BETWEEN NEW | | | CLOSET AND BATH AT BEDROOM 1 AND THAT OPENING IS NOT | | | PRESENT ON SHEET 2- PLEASE COORDINATE. | | | | | | SHEET 5 | | | | | | DETAIL SLAB AND FOUNDATION FOR NEW PROPOSED AREA | | | | | | END OF BUILDING COMMENTS | | | | | | ANY QUESTIONS OR CONCERNS: | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-07-11 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-07-11 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2023-07-11 14:46:49 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE ONE-LINE DIAGRAM SHOWING INFORMATION OF | | | SERVICE EQUIPMENT (SERVICE OVERCURRENT PROTECTION, | | | SERVICE CONDUCTORS, AND GROUNDED ELECTRICAL CONDUCTOR) | | | AS PER NEC 230, 240. 250 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN P. PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER/ INSPECTOR | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-07-19 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-07-19 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-21 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-29 |
Time |
11:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-21 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-21 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2023-07-21 10:01:23 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23060406 | | | | | | REVIEWED: 7.21.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-07-19 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-07-19 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-07-03 |
Time |
06:08 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-07-03 |
Time |
06:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-21 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-21 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2023-07-21 10:30:16 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23060406 | | | | | | REVIEWED: 7.21.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | ROOF COMMENTS: FAILED | | | | | | AS PER SECTION 107.2.1 | | | PROVIDE STRUCTURAL ENGINEER DRAWINGS DIGITALLY SIGNED | | | AND SEALED APPROVED CALCULATION, ZONE AND PRESSURE FOR | | | PROPOSED NEW ROOF AND TRUST SYSTEM. | | | ROOD SHEETING NAILING PATTERN. | | | CONNECTOR SCHEDULE | | | PLYWOOD NAILING DETAILS | | | TRUSS TO TIE BEAM CONNECTION DETAILS | | | ROOF PLAN NOTES | | | NOA FOR NEW PROPOSED ROOF ASSEMBLY | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE NARRATIVE FOR EACH COMMENT ABOVE TO | | | FACILITATE ADDITIONAL REVIEW. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-21 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-21 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2023-07-21 09:58:29 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT:23060406 | | | | | | REVIEWED: 7.21.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | PLAN BY FL. LICENSES ENGINEERS/ARCHITECTS THAT ARE | | | SUBMITTED ELECTRONICALLY SHALL BEAR VERIFIABLE, | | | ORIGINAL DIGITAL SIGNATURE AND SEALS- FL STATUTE | | | 471.025 AND SEC 61G15-23.005 FLORIDA ADMINISTRATIVE | | | CODE. | | | USING BLUEBEAM REVU, ADOBE OR SIMILAR SOFTWARE THAT | | | ALLOW TO VALIDATE DIGITAL SIGNATURE CERTIFICATE, PLEASE | | | RESUBMIT ORIGINALS. THE CERTIFICATE WILL SHOW IN GREEN, | | | YELLOW OR BLUE TO BE VALID. | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-07-19 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-07-19 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|