Plan Review Details - Permit 23060371
Plan Review Stops For Permit 23060371
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-06-20 Cont ID  
Sent By cpuell Date 2023-06-20 Time 08:25 Rev Time 0.00
Received By cpuell Date 2023-06-20 Time 08:25 Sent To  
Notes
2023-06-20 08:25:49ADDRESS APPROPRIATE FOR PROJECT.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-06-30 Cont ID  
Sent By rmcphers Date 2023-06-30 Time 09:25 Rev Time 0.00
Received By rmcphers Date 2023-06-30 Time 09:25 Sent To  
Notes
2023-06-30 09:26:08PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-06-30 Cont ID  
Sent By rmcphers Date 2023-06-30 Time 09:52 Rev Time 0.00
Received By rmcphers Date 2023-06-29 Time 11:15 Sent To  
Notes
2023-06-30 09:52:11REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS AND DOORS -
 ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE ENGINEER OF RECORD FBC WPB 107.3.4
  
 2) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET PAPER
 HOLDER DIMENSIONS FROM THE FACE OF THE TOILET TO THE
 CENTER OF THE TOILET PAPER HOLDER FBC A 604.7
 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 3) ACCESSIBLE RESTROOM - PLEASE USE THE WORDS
 "REFLECTIVE SURFACE" WHEN REFERRING TO THE DIMENSIONS
 OF THE MIRROR FROM THE FLOOR - FBC A 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND
  
 4) ACCESSIBLE RESTROOM - PLEASE SHOW THE TOILET GRAB
 BAR HEIGHT TO THE TOP OF THE GRIPPING SURFACE (NOT TO
 THE CENTER OF THE BAR) - FBC A 609.4 POSITION OF GRAB
 BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE
  
 5) EXTERIOR WINDOW AND DOOR PRODUCT APPROVALS MAY BE
 DEFERRED SUBMITTALS BY LISTING THE ITEMS TO BE DEFERRED
 ON THE CONSTRUCTION DOCUMENTS - FBC WPB107.3.4.1
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-06-26 Cont ID  
Sent By jleahy Date 2023-06-26 Time 14:26 Rev Time 0.00
Received By jleahy Date 2023-06-26 Time 13:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-06-23 Cont ID  
Sent By pleduc Date 2023-06-23 Time   Rev Time 0.00
Received By pleduc Date 2023-06-21 Time 13:48 Sent To  
Notes
2023-06-23 14:56:13FIRE PREVENTION COMMENT:
  
 IT APPEARS THAT ONLY 2 FIRE EXTINGUISHERS ARE REQUIRED
 IN THIS OCCUPANCY.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-05 Cont ID  
Sent By cmontell Date 2023-07-05 Time 14:04 Rev Time 0.00
Received By cmontell Date 2023-07-05 Time 14:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-05 Cont ID  
Sent By cmontell Date 2023-07-05 Time 14:03 Rev Time 0.00
Received By cmontell Date 2023-07-05 Time 14:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-06-22 Cont ID  
Sent By rwbrown Date 2023-06-22 Time 14:13 Rev Time 0.00
Received By rwbrown Date 2023-06-22 Time 14:13 Sent To  
Notes
2023-06-22 14:16:461ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 607.1.2/419.5 - PLEASE SHOW A DETAIL FOR
 THE INSTA-HOT WATER HEATERS THAT SHOW COMPLIANCE WITH
 ASSE 1070 PER THIS SECTION.
  
 2. 2020 FPC 403.1.1 - PLEASE INCLUDE THE OCCUPANT LOAD
 OF THE CLUBHOUSE TO SHOW THAT YOU HAVE THE REQUIRED
 BATHROOMS FOR THE OCCUPANT LOAD.
  
 3. 2020 FBC 454.1.6.1 - PLEASE SHOW THE OCCUPANT LOAD
 OF THE POOL. IF YOU DON'T MEE THE EXCEPTION, SHOW THAT
 THE POOL BATH MEETS THE REQUIREMENTS OF 2020 FBC 454.6.
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-06-26 Cont ID  
Sent By jleahy Date 2023-06-26 Time 14:27 Rev Time 0.00
Received By jleahy Date 2023-06-26 Time 14:27 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-06-23 Cont ID  
Sent By asangele Date 2023-06-23 Time 13:23 Rev Time 0.00
Received By asangele Date 2023-06-23 Time 13:23 Sent To  
Notes
***NONE***