| Plan Review Stops For Permit 23060236 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-12 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-12 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-28 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-28 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2023-06-28 13:39:33 | CANOPY FACE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) CANOPY FACING IS SUBJECT TO WIND LOADS FBC 1609 - | | | PLEASE PROVIDE SIGNED AND SEALED ATTACHMENT DETAILS | | | FROM A DESIGN PROFESSIONAL - SHOW THE WIND DESIGN DATA | | | ON THE DRAWING DETAILS - FBC 1603 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-24 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-24 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-06-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-06-17 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-06-17 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2023-06-17 09:27:18 | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | VALUE FOR PROJECT SEEMS LOW PLEASE SUBMIT A COST | | | BREAKDOWN OF ALL LABOR AND MATERIALS. | | | | | | FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING | | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE | | | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-12 |
Time |
15:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-06-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-06-09 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-24 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-11 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-28 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-08 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-24 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-06-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-06-17 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-06-17 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2023-06-17 10:52:52 | | | | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY THE DESIGN | | | PROFESSIONAL RESPONSIBLE FOR THE DESIGN. WPB 107.2.1 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-07-14 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-07-14 |
Time |
09:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-06-22 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-06-22 |
Time |
14:43 |
Sent To |
|
|
| Notes |
|
|