|
 |
 |
 |
 |
 |
Plan Review Details - Permit 23060224
| Plan Review Stops For Permit 23060224 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-13 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-13 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2023-07-13 11:54:13 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | | OF PROVIDING POSITIVE DRAINAGE. SECOND REQUEST. | | | 2. PLEASE ADDRESS THE SIGNATURE REVIEW COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-26 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-26 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2023-06-26 11:30:20 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED FORM 400 IS A PALM BEACH | | | COUNTY BUILDING DEPARTMENT DOCUMENT AND IS NOT APPROVED | | | FOR USE AS A SUBSTITUTE FOR SIGNED AND SEALED ENHANCED | | | NAILING CALCULATIONS BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPARTMENT THE AUTHORITY OF JURISDICTION. | | | GENERAL LIMITATION #7 IS SPECIFICALLY REFERRED TO IN | | | THIS NOA. SUBMIT FASTENER DENSITY CALCULATIONS | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED ARCHITECT, OR | | | REGISTERED ROOF CONSULTANT. | | | 2. FBC B 107.2.1 FBC EB 706.1 SUBMITTED ROOF | | | DRAWING/SKETCH LISTS FLAT/LOW ROOF SLOPE AS 0:12; LOW | | | SLOPE ROOFS MUST SHOW POSITIVE DRAINAGE. PROVIDE METHOD | | | OF PROVIDING POSITIVE DRAINAGE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-13 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-12 |
Time |
10:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-26 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-23 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-09-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-09-26 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-09-26 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-13 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-13 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2023-07-13 11:56:34 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PLEASE | | | UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | | PROJECTDOX | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |