| Plan Review Stops For Permit 23060136 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-06-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-23 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-23 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-13 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-13 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2023-06-13 16:10:14 | 2ND REVIEW FBC-2020 RES. GAS | | | PERMIT- 23060136 | | | 6/13/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE NEW RISER DRAWING BY THE CONTRACTOR IS APPROVED | | | AND HAS SUPERCEDED SHEET P3.1, HOWEVER SHEET P2.3 WHICH | | | IS THE GAS APPLIANCE FLOOR PLAN DRAWING STILL REQUIRES | | | A VERIFIABLE DIGITAL SIGNATURE AND SEAL BY THE ENGINEER | | | OF RECORD- FL. STATUTE 471.025 AND SEC. 61G15-23.005 | | | FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-07 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-07 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2023-06-07 16:58:44 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 23060136 | | | 6/7/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P3.1 GAS RISER CORRECTIONS: | | | | | | A) TOTAL LOAD SHOWN ON RISER IS 1,721,700 BTUH, LOAD IN | | | SCHEDULE IS 1,138,000. | | | | | | B) PIPE TYPE, SIZE, AND LENGTH FROM LOW PRESSURE | | | REGULATOR TO GENERATOR NOT SHOWN. | | | | | | C) LOW PRESSURE REGULATOR BY GWH-2 NOT LABELED. | | | | | | D) LOW PRESSURE 1/2--INCH STEEL PIPE FOR A LOAD OF | | | 330,000 AT TOTAL DEVELOPED LENGTH OF 40 FT. IS | | | UNDERSIZED PER TABLE 402.4(2). THE MINIMUM SIZE | | | REQUIRED IS 1-1/4-INCH. | | | | | | E) LOW PRESSURE CSST LOAD OF 659,000 BTUH IS INCORRECT. | | | THE LOAD SHOWN IS 140,000 BTUH. | | | | | | F) LOW PRESSURE CSST SIZE OF 25 EHD MUST BE INCREASED | | | TO EHD 30 PER TABLE 402.4(15) | | | | | | G) LOW PRESSURE 1/2--INCH STEEL DROP TO 100,000 BTUH | | | COOKTOP SHALL BE INCREASED TO 3/4-INCH- TABLE 402.4(2). | | | | | | H) PIPE TYPE, SIZE, AND LENGTH FROM LOW PRESSURE | | | REGULATORS TO GWH-2, POOL HEATER, NOT SHOWN. | | | | | | I) LOW PRESSURE CSST SIZE OF 19 EHD SHALL BE INCREASED | | | TO 25 EHD PER TABLE 402.4(15). | | | | | | J) LOCATION OF GWH-1 NOT SHOWN. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-06-21 |
Time |
15:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-06-12 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-06 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2023-06-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-23 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-23 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-13 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-13 |
Time |
15:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-07 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-07 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-06-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-23 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-23 |
Time |
16:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-13 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-13 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2023-06-13 16:07:47 | 2ND SIGNATURE REVIEW | | | PERMIT- 23060136 | | | 6/13/23 | | | | | | CODES IN EFFECT: | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) 2ND REQUEST FOR DIGITALLY SIGNED AND SEAL PLAN SHEET | | | P2.3 AS REQUIRED BY FL. STATUTE 471.025 AND SEC. | | | 61G15-23.005 FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-07 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-07 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2023-06-07 17:13:16 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 23060136 | | | 6/7/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE REVISED PLAN SHEETS P2.3 & P3.1 ARE NOT | | | DIGITALLY SIGNED AND SEALED BY THE ENGINEER OF RECORD- | | | FL. STATUTE 471.025 AND SEC. 61G15-23.005 FAC. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|