Plan Review Details - Permit 23060084
Plan Review Stops For Permit 23060084
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-06-22 Cont ID  
Sent By lbond Date 2023-06-22 Time 13:32 Rev Time 0.00
Received By lbond Date 2023-06-22 Time 13:32 Sent To  
Notes
2023-06-22 13:38:36 
  
  
 FBC 1017.2.1
 CLARIFY SCOPE:
  
  
 R4501.17.1.2 THE BARRIER MAY NOT
 HAVE ANY GAPS, OPENINGS,
 INDENTATIONS, PROTRUSIONS, OR
 STRUCTURAL COMPONENTS THAT COULD
 ALLOW A YOUNG CHILD TO CRAWL UNDER,
 SQUEEZE THROUGH, OR CLIMB OVER
 THE BARRIER AS HEREIN DESCRIBED
 BELOW. ONE END OF A REMOVABLE
 CHILD BARRIER SHALL NOT BE
 REMOVABLE WITHOUT THE AID OF TOOLS.
 OPENINGS IN ANY BARRIER SHALL NOT
 ALLOW PASSAGE OF A 4-INCHDIAMETER
 (102 MM) SPHERE.
  
 R4501.17.1.8 ACCESS GATES, WHEN PROVIDED, SHALL BE
 SELF-CLOSING AND SHALL COMPLY WITH THE REQUIREMENTS OF
 SECTIONS R4501.17.1.1 THROUGH R4501.17.1.7 AND
 SHALL BE EQUIPPED WITH A SELF-LATCHING LOCKING DEVICE
 LOCATED ON THE POOL SIDE OF THE GATE. WHERE THE
 DEVICE RELEASE IS LOCATED NO LESS THAN 54 INCHES
 (1372 MM) FROM THE BOTTOM OF THE GATE, THE DEVICE
 RELEASE MECHANISM MAY BE LOCATED ON EITHER SIDE OF
 THE GATE AND SO PLACED THAT IT CANNOT BE REACHED BY A
 YOUNG CHILD OVER THE TOP OR THROUGH ANY OPENING OR
 GAP FROM THE OUTSIDE. GATES THAT PROVIDE ACCESS TO
 THE SWIMMING POOL MUST OPEN OUTWARD AWAY FROM THE
 POOL. THE GATES AND BARRIER SHALL HAVE NO OPENING
 GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18 INCHES (457
 MM) OF THE RELEASE MECHANISM
  
 PLEASE PROVIDE SPEC FOR PROPOSED POOL BARRIER
  
 IF YOU HAVE ANY QUESTIONS OF CONCERNS, YOU CAN CONTACT
 ME:
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-30 Cont ID  
Sent By aoliver Date 2023-06-30 Time 14:24 Rev Time 0.00
Received By aoliver Date 2023-06-06 Time 07:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-06-30 Cont ID  
Sent By lgelman Date 2023-06-30 Time 14:06 Rev Time 0.00
Received By lngelman Date 2023-06-30 Time 14:04 Sent To  
Notes
2023-06-30 14:05:56CLARIFY MATERIAL ON SURVEY AND INDICATE DISTANCE
 MEASUREMENTS FROM POOL BARRIER TO EXISTING FENCE.
  
 *****REVIEWED BY*****
 LINDSEY GELMAN
 561-822-1275
 [email protected]