Plan Review Details - Permit 23051704
Plan Review Stops For Permit 23051704
Review Stop ENG ENGINEERING CSD
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2023-06-23 Cont ID  
Sent By cseifer Date 2023-06-23 Time 11:06 Rev Time 0.00
Received By cseifer Date 2023-06-23 Time 10:20 Sent To  
Notes
2023-06-23 11:05:56THE PAVER DRIVEWAY AGREEMENT IS A REQUIREMENT IF PAVERS
 ARE USED IN THE RIGHT OF WAY PORTION OF THE DRIVEWAY.
 THE AGREEMENT SHALL SHOW PROPERTY ADDRESS, PCN NUMBER,
 PLAT BOOK AND PAGE NUMBERS AND MUST THEN BE RECORDED BY
 APPLICANT AT PALM BEACH COUNTY COURTHOUSE - RECORDING
 DEPT. 4.25. A RECORDED COPY OF THIS DOCUMENT SHOULD
 THEN BE FAXED TO (561) 494-1116. ATTENTION: DRIVEWAY
 REVIEWER, AND ALSO UPLOADED WITH RESUBMITTAL OF
 DEVELOPMENT SERVICES APPLICATION FOR DRIVEWAY. DOCUMENT
 NEEDS TO BE RECORDED PRIOR TO FINAL SIGN OFF.
  
 FOR A PDF COPY OF THE PAVER DRIVEWAY AGREEMENT GO TO:
 HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3298/637
 523652570000000
  
 TO RESUBMIT, YOU MUST FIRST WAIT TILL ALL THE PLAN
 REVIEWS ARE COMPLETE. EVEN IF YOU FAILED ONE TRADE AND
 WANT TO ADDRESS THE COMMENTS IMMEDIATELY, YOU MUST WAIT
 FOR ALL OTHER TRADES TO REVIEW YOUR PLAN. RESUBMITTING
 BEFORE PLAN REVIEW IS COMPLETE WILL DELAY YOUR PLAN
 REVIEW TIME.
  
 ONCE ALL PLAN REVIEWS ARE COMPLETE, IF YOU DON???T
 UNDERSTAND THE FAILED PLAN REVIEW COMMENTS, AS A BEST
 PRACTICE YOU SHOULD CALL OR EMAIL YOUR PLAN REVIEWER TO
 DISCUSS. EVERY PLAN REVIEWER INCLUDES THEIR NAME, PHONE
 AND EMAIL ADDRESS IN THE COMMENTS. TO VIEW YOUR PLAN
 REVIEW COMMENTS ONLINE, GO TO THE DEVELOPMENT SERVICES
 WEBSITE AT HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-S
 ERVICES/PERMITS AND SEE ???WHERE CAN I FIND MY PLAN
 REVIEW COMMENTS ONLINE???? FOR INSTRUCTIONS.
  
 FOR QUESTIONS ABOUT HOW TO RESUBMIT, SEE INFO ON
 WEBSITE OR EMAIL [email protected] AND A BUILDING DIVISION
 TEAM MEMBER WILL HELP YOU.
  
 THANKS,
 CHLOE SEIFER, PROJECT COORDINATOR, ENGINEERING SERVICES
 DEPARTMENT, [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By aoliver Date 2023-07-21 Time 08:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-30 Cont ID  
Sent By lngelman Date 2023-06-30 Time 12:21 Rev Time 0.00
Received By lngelman Date 2023-06-06 Time 16:48 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status N Date 2023-07-21 Cont ID  
Sent By aoliver Date 2023-07-21 Time 08:25 Rev Time 0.00
Received By aoliver Date 2023-07-21 Time 08:25 Sent To  
Notes
2023-07-21 08:26:12PP INSPECTIONS ONLY, APPROVED UNDER MASTER 22010180

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-06-30 Cont ID  
Sent By lgelman Date 2023-06-30 Time 12:18 Rev Time 0.00
Received By lngelman Date 2023-06-30 Time 12:09 Sent To  
Notes
2023-06-30 12:18:15PURSUANT TO SECTION 94-482 OF THE ZLDR: REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA SHALL BE LANDSCAPED WITH LIVING PLANT
 MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS, HEDGES,
 VINES OR TREES). EXPANSIONS TO EXISTING OFF-STREET
 PARKING SPACES AND DRIVEWAYS WITHIN A FRONT YARD OR A
 CORNER SIDE YARD SHALL BE SET BACK A MINIMUM OF FIVE
 FEET FROM A FRONT AND/OR CORNER SIDE PROPERTY LINE AND
 THREE FEET FROM A SIDE OR REAR PROPERTY LINE, EXCEPT
 FOR THAT PORTION OF THE DRIVEWAY ADJOINING THE APRON.
  
 PURSUANT TO SECTION 94-312 OF THE ZLDR: TWO DRIVEWAYS
 EACH WITH A WIDTH OF NO GREATER THAN TEN FEET AT THE
 PROPERTY LINE OR WHERE THE DRIVEWAY ADJOINS THE APRON
 IF THE APRON IS NOT LOCATED WHOLLY WITHIN THE
 RIGHT-OF-WAY, PROVIDED THAT THE DRIVEWAYS SHALL BE ON
 TWO DIFFERENT STREET FRONTAGES OR ON ONE STREET
 FRONTAGE AND THE ALLEY.
  
 PROVIDE A SITE PLAN THAT SHOWS THE PROPOSED DRIVEWAY
 MEASURMENTS AND SETBACK MEASUREMENTS FOR THE FRONT AND
 SIDE YARDS. MAXIMUM COMBINED DRIVEWAY WIDTH IS 20 FEET,
 IF TWO DRIVEWAYS, THE MAXIMUM WIDTH FOR EACH DRIVEWAY
 IS 10 FEET (MEASURED AT THE PROPERTY LINE).
  
 PROVIDE LOT COVERAGE DETAILS FOR FRONT YARD (FIRST 25
 FEET FROM NORTH PROPERTY LINE) AND INCLUDE
 IMPERVIOUS/PERVIOUS DATA FOR PROPOSED DRIVEWAY. MAXIMUM
 ALLOWED PAVERS IS 25% OF FRONT YARD.
  
 *****REVIEWED BY*****
 LINDSEY GELMAN
 561-822-1275
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved