Plan Review Details - Permit 23051386
| Plan Review Stops For Permit 23051386 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-30 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-30 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-21 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-21 |
Time |
11:41 |
Sent To |
|
|
| Notes |
| 2023-06-21 12:19:46 | 2ND REVIEW FBC-2020 RES. GAS | | | PERMIT- 23051386 | | | 6/21/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) NEW GAS RISER: PLEASE IDENTIFY THE PIPING AS EITHER | | | SCHEDULE 40 METALLIC, COPPER, PE, OR CSST PER SEC. | | | G2414.1 FBC RES. FLEX IS NOT AN APPROVED MATERIAL. IF | | | THE PIPING IS CSST, PLEASE PROVIDE THE EHD OF THE | | | PIPING AS REQUIRED BY TABLES G2413.4(16) & G2413.17 FBC | | | RES. | | | | | | A) THE SPECS FOR THE WATER HEATER INDICATE THE REQUIRED | | | INPUT PRESSURE IS 3.5" TO 10.5" WC HOWEVER THE PRESSURE | | | AT THE METER IS 2 P.S. I. WHICH REQUIRES INSTALLATION | | | OF A STEP-DOWN REGULATOR. PLEASE SHOW THE REGULATOR ON | | | THE RISER AND CORRECT THE NOTES INDICATING THE | | | REGULATOR IS INTEGRAL TO THE WATER HEATER- SEC. G2421.2 | | | FBC RES. | | | | | | 2) THE WATER HEATER SHALL BE INSTALLED A MINIMUM OF 4 | | | FT. FROM THE WINDOW OPENINGS REGARDLESS IF THE WINDOWS | | | ARE BOARDED UP. PLEASE SHOW THE CLEARANCE DISTANCES ON | | | THE PLAN- SEC. G2427.8 FBC RES. | | | | | | 3) AS PREVIOUSLY REQUESTED, PROVIDE THE PIPE SIZING | | | TABLES USED- SEC. G2413.4. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-06-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-12 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-12 |
Time |
12:59 |
Sent To |
|
|
| Notes |
| 2023-06-12 14:12:24 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 23051386 | | | 6/12/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE GAS RISER IS INCOMPLETE. PLEASE PROVIDE THE | | | FOLLOWING INFORMATION- SEC. 107.3.5.3 WPB AND SECS. | | | G2412.4 & G2413.1 FBC RES. | | | A) SHOW THE LOCATION OF THE METER AND DELIVERY | | | PRESSURE. | | | B) SHOW THE INDIVIDUAL BTU LOADS OF THE EXISTING RANGE, | | | POOL HEATER AND THE NEW WATER HEATER, AND THE TOTAL | | | LOAD OF THE SYSTEM. | | | C) SHOW THE BRANCH PIPING LENGTH MEASUREMENTS AND THE | | | TOTAL DEVELOPED LENGTH OF THE PIPING RUN FROM THE METER | | | TO THE MOST REMOTE APPLIANCE. | | | D) SHOW THE LOCATIONS OF REGULATORS AND OUTLET | | | PRESSURES. | | | E) PROVIDE THE PIPE SIZING TABLES USED. | | | | | | 2) SHOW THE CLEARANCE DISTANCE MEASUREMENTS FROM THE | | | WATER HEATER EXHAUST TO AIR INTAKES AND OPERABLE | | | OPENINGS INTO THE HOUSE- SECS. G2427.8 & G2448.1 FBC | | | RES. | | | | | | 3) SIGNATURE OF THE CONTRACTOR OR QUALIFIER SHALL BE ON | | | THE DRAINGS- SEC. 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-06-29 |
Time |
09:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-06-20 |
Time |
10:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
cdecoeur |
Date |
2023-06-08 |
Time |
08:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-30 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-30 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-21 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-12 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-12 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-06-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-12 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-12 |
Time |
12:59 |
Sent To |
|
|
| Notes |
|
|
|