| Plan Review Stops For Permit 23051118 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-22 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-22 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-07-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-08 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-08 |
Time |
07:23 |
Sent To |
|
|
| Notes |
| 2023-07-08 08:46:18 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | | SATISFACTORILY ARE MARKED AS CORRECTED OR REMOVED. | | | PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED | | | SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN | | | PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER | | | PREVIOUS COMMENTS. | | | | | | | | | 1. CORRECTED | | | | | | 2. PROVIDE STRUCTURAL DETAILS OF SITE WALLS. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 3. PROVIDE DETAILS/SPECIFICATIONS OF SHEET PILES. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | NEW COMMENTS: | | | | | | NOTICE: REMOVE PLAN PAGES THAT ARE NOT RELEVANT TO THE | | | SCOPE OF WORK (SOW), SITE WALLS. | | | | | | 4. PROVIDE DETAILS FOR COLUMNS AT DRIVEWAY. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 5. AN ELEVATION CERTIFICATE IS NOT REQUIRED FOR SITE | | | WALLS. DESIGN OF WALLS AND COLUMNS SHALL COMPLY WITH | | | FBC R322. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-10 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-06-10 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2023-06-10 10:36:02 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. IDENTIFY LOCATION OF SITE WALLS ON SITE PLAN. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 2. PROVIDE STRUCTURAL DETAILS OF SITE WALLS. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 3. PROVIDE DETAILS/SPECIFICATIONS OF SHEET PILES. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-07-25 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-07-17 |
Time |
08:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
lngelman |
Date |
2023-07-11 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-07-07 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
lngelman |
Date |
2023-06-20 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-06-09 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-22 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-22 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-22 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-08 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-08 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-06-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-10 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-06-10 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2023-06-10 10:28:21 | 1ST SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: PLAN PAGE - A2 | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
lngelman |
Date |
2023-07-11 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-07-11 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2023-07-11 13:27:57 | PERMIT IS FOR SITE WALL ONLY. SITE WALL OK | | | | | | *****REVIEWED BY***** | | | LINDSEY GELMAN | | | 561-822-1275 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
lgelman |
Date |
2023-06-20 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-06-20 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2023-06-20 11:20:01 | PER CODE SECTION 94-302. IN RESIDENTIAL DISTRICTS, NO | | | FENCE OR WALL SHALL EXCEED SIX FEET IN HEIGHT WITHIN | | | REQUIRED SIDE AND REAR SETBACKS. FENCES OR WALLS SHALL | | | NOT BE IN EXCESS OF 48 INCHES IN HEIGHT WITHIN THE | | | REQUIRED FRONT SETBACK. HEDGES SHALL NOT EXCEED TEN | | | FEET IN HEIGHT IN ANY REQUIRED SETBACK. | | | | | | SHOW FRONT SITE WALL TO BE IN COMPLIANCE WITH 4 FOOT | | | HEIGHT MAXIMUM. | | | | | | | | | ****REVIEWED BY***** | | | LINDSEY GELMAN | | | 561-822-1275 | | | [email protected] |
|
|