2023-07-26 09:41:04RESIDENTIAL (R3)RE-ROOF SIXTH BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23051022
 333 MURRAY RD
  
 PREVIOUS COMMENT FOR FLAT ROOF:
 2- NEW FLAT ROOF NOA 22-0706.08 WAS SUBMITTED. NEED TO
 CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS GOING TO BE
 INSTALLED. IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED. SEE GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
  
 RESPONSE:
 NEW FLORIDA PRODUCT APPROVAL FL16717-R13 SUBMITTED. THE
 DESIGN PRESSURES OF -112.5 PSF OF SELECTED ASSEMBLY
 W107 DON'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES
 #3 FOR THIS TWO STORY BUILDING AS REQUIRED BY
 SEC.R301.2.1 FBC-RESIDENTIAL. NEED TO PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS AS REQUIRED BY
 LIMITATION #5.7.2 OF PRODUCT APPROVAL SUBMITTED.
  
  
 PREVIOUS COMMENT:
 4- NEW ROOFING UNDERLAYMENT FLORIDA PRODUCT APPROVAL
 FL5259-R39 SUBMITTED DOESN'T IDENTIFY WHICH APPROVED
 ASSEMBLY IS GOING TO BE INSTALLED. CLEARLY MARK WHICH
 APPROVED ASSEMBLY FROM SECTION 6.1 OF PRODUCT APPROVAL
 SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 UNDERLAYMENT SELECTED IS POLYSTICK TU MAX AND SELECTED
 APPROVED ASSEMBLY 6.3.12 ON PAGE 9 OF 9 IS FOR CONCRETE
 DECKS. THIS HOUSE DOESN'T HAVE A CONCRETE DECK. NEED TO
 SELECT ASSEMBLY FOR DECK TYPE THAT MATCHES THIS HOUSE.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2023-07-19 Cont ID  
Sent By jgomez Date 2023-07-19 Time 16:17 Rev Time 0.00
Received By jgomez Date 2023-07-19 Time 15:44 Sent To  
Notes
2023-07-19 16:17:17RESIDENTIAL (R3) RE-ROOF FIFTH BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23051022
 333 MURRAY RD
  
 PREVIOUS COMMENT FOR FLAT ROOF:
 2- NEW FLAT ROOF NOA 22-0706.08 WAS SUBMITTED. NEED TO
 CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS GOING TO BE
 INSTALLED. IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED. SEE GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
  
 PREVIOUS COMMENT:
 4- TU PLUS FLORIDA PRODUCT APPROVAL FL-5259-R38
 SUBMITTED SAYS "PENDING FBC APPROVAL". NEED TO PROVIDE
 APPROVED PRODUCT APPROVAL.
 F.A.C. 61G20.3.001.
  
 RESPONSE:
 NEW FLORIDA PRODUCT APPROVAL FL5259-R39 SUBMITTED
 DOESN'T IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO BE
 INSTALLED. CLEARLY MARK WHICH APPROVED ASSEMBLY FROM
 SECTION 6.1 OF PRODUCT APPROVAL SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 19:04 Rev Time 0.00
Received By jgomez Date 2023-07-10 Time 18:41 Sent To  
Notes
2023-07-10 19:04:17RESIDENTIAL (R3) RE-ROOF FOURTH BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23051022
 333 MURRAY RD
  
 PREVIOUS COMMENT FOR FLAT ROOF:
 2- NEW FLAT ROOF NOA 22-0706.08 WAS SUBMITTED. NEED TO
 CLEARLY MARK/IDENTIFY WHICH ASSEMBLY IS GOING TO BE
 INSTALLED. IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED. SEE GENERAL
 LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
  
 PREVIOUS COMMENT:
 4- TU PLUS FLORIDA PRODUCT APPROVAL FL-5259-R38
 SUBMITTED SAYS "PENDING FBC APPROVAL". NEED TO PROVIDE
 APPROVED PRODUCT APPROVAL.
 F.A.C. 61G20.3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-06-28 Cont ID  
Sent By jgomez Date 2023-06-28 Time 17:30 Rev Time 0.00
Received By jgomez Date 2023-06-28 Time 15:42 Sent To  
Notes
2023-06-28 17:31:29RESIDENTIAL (R3) RE-ROOF THIRD BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23051022
 333 MURRAY RD
  
  
 PREVIOUS COMMENT:
 2- FLAT ROOF FL16717-R13 SUBMITTED.
 SELECTED ASSEMBLY W-107 ON PAGE 22 OF 87 DOESN'T MEET
 THE DESIGN PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS AS REQUIRED BY LIMITATION
 5.7.2 ON PAGE 5 OF 5 OR SELECT ANOTHER ASSEMBLY THAT
 MEETS THE DESIGN PRESSURES FOR ALL ROOF ZONES.
 NOTE: SEE FLAT ROOF LOCATED ON THE SECOND FLOOR.
 CLEARLY SPECIFY THE HEIGHT OF ALL ROOFS. SEC. 107.2.1
 CITY AMENDMENTS. SEC. R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 NEW NOA 22-0706.08 WAS SUBMITTED. NEED TO CLEARLY
 MARK/IDENTIFY WHICH ASSEMBLY IS GOING TO BE INSTALLED.
 IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN PRESSURES
 FOR ALL ROOF ZONES, THEN SIGNED AND SEALED RAS 117
 CALCULATIONS ARE REQUIRED. SEE GENERAL LIMITATION #7 ON
 LAST PAGE OF NOA SUBMITTED.
  
 PREVIOUS COMMENT:
 3- ROOF TILE NOA 22-0714.18 AND ROOF TILE ADHESIVE
 FL6332-R9 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE
 TO BE USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING
 PERMITS TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES
 OF SEC R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 PREVIOUS COMMENT:
 4- TU PLUS FLORIDA PRODUCT APPROVAL FL-5259-R38
 SUBMITTED SAYS "PENDING FBC APPROVAL". NEED TO PROVIDE
 APPROVED PRODUCT APPROVAL.
 F.A.C. 61G20.3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-06-05 Cont ID  
Sent By jgomez Date 2023-06-05 Time 15:30 Rev Time 0.00
Received By jgomez Date 2023-06-05 Time 14:29 Sent To  
Notes
2023-06-05 15:30:32RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23051022
 333 MURRAY RD
  
 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER,
 THE VALUE OF THE STRUCTURE IS MORE THAN $300,000. NEED
 TO COMPLY WITH THE ROOF TO WALL CONNECTIONS AS REQUIRED
 BY SEC. 706.8 FBC-EXISTING BUILDING. PROVIDE COMPLETE
 INFORMATION SHOWING COMPLIANCE WITH THE ROOF TO WALL
 CONNECTIONS.
 NOTE: A SEPARATE SUB-PERMIT IS REQUIRED FOR ROOF TO
 WALL CONNECTIONS. THIS WORK CAN NOT BE DONE BY THE
 ROOFING CONTRACTOR UNLESS ROOFING CONTRACTOR POSSESSES
 THE PROPER LICENSE TO PERFORM THIS WORK.
  
 RESPONSE:
 GENERAL CONTRACTOR "NEW ROOF INSTALLATION" LETTER:
 A) CONTRACTOR NEEDS TO SHOW IN DETAIL WHAT DOES THE
 COST OF $10,732 COVERS FOR ROOF TO WALL CONNECTIONS
 REQUIRED BY SEC. 706.8 FBC-EXISTING BUILDING.
 NOTE: THE 15 PERCENT EXCEPTION APPLIES ONLY IF THE
 EVALUATION AND INSTALLATION OF CONNECTIONS AT GABLE
 ENDS OR ALL CORNERS CANNOT BE COMPLETED FOR 15 PERCENT
 OF THE COST OF ROOF REPLACEMENT. SEE SEC. 706.8
 FBC-EXISTING BUILDING.
  
 B) CONTRACTOR NEEDS TO SIGN THE LETTER.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 2- FLAT ROOF FL16717-R13 SUBMITTED.
 SELECTED ASSEMBLY W-107 ON PAGE 22 OF 87 DOESN'T MEET
 THE DESIGN PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS AS REQUIRED BY LIMITATION
 5.7.2 ON PAGE 5 OF 5 OR SELECT ANOTHER ASSEMBLY THAT
 MEETS THE DESIGN PRESSURES FOR ALL ROOF ZONES.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
 NOTE: SEE FLAT ROOF LOCATED ON THE SECOND FLOOR.
 CLEARLY SPECIFY THE HEIGHT OF ALL ROOFS. SEC. 107.2.1
 CITY AMENDMENTS. SEC. R301.2.1 FBC-RESIDENTIAL.
  
 3- ROOF TILE NOA 22-0714.18 AND ROOF TILE ADHESIVE
 FL6332-R9 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE
 TO BE USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING
 PERMITS TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES
 OF SEC R301.2.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 4- TU PLUS FLORIDA PRODUCT APPROVAL FL-5259-R38
 SUBMITTED SAYS "PENDING FBC APPROVAL". NEED TO PROVIDE
 APPROVED PRODUCT APPROVAL.
 F.A.C. 61G20.3.001.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 5- HIP AND RIDGE TILE INSTALLATION. PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS FOR HIP AND RIDGE
 INSTALLATION AS REQUIRED BY SEC. R905.3.7.1
 FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS IN ACCORDANCE
 WITH FRSA/TRI FLORIDA HIGH WIND CONCRETE AND CLAY TILE
 INSTALLATION MANUAL (6TH EDITION) OR THE
 RECOMMENDATIONS OF RAS 118, 119 OR 120.
 ALTERNATIVE: IF USING METAL SUPPORT, THEN PROVIDE
 PRODUCT APPROVAL FOR HIP AND RIDGE METAL SUPPORT AND
 CLEARLY MARK ATTACHMENT METHOD.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-26 Cont ID  
Sent By jgomez Date 2023-05-26 Time 17:31 Rev Time 0.00
Received By jgomez Date 2023-05-26 Time 15:25 Sent To  
Notes
2023-05-26 17:31:18RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23051022
 333 MURRAY RD
  
 1- ACCORDING TO PALM BEACH COUNTY PROPERTY APPRAISER,
 THE VALUE OF THE STRUCTURE IS MORE THAN $300,000. NEED
 TO COMPLY WITH THE ROOF TO WALL CONNECTIONS AS REQUIRED
 BY SEC. 706.8 FBC-EXISTING BUILDING. PROVIDE COMPLETE
 INFORMATION SHOWING COMPLIANCE WITH THE ROOF TO WALL
 CONNECTIONS.
 NOTE: A SEPARATE SUB-PERMIT IS REQUIRED FOR ROOF TO
 WALL CONNECTIONS. THIS WORK CAN NOT BE DONE BY THE
 ROOFING CONTRACTOR UNLESS ROOFING CONTRACTOR POSSESSES
 THE PROPER LICENSE TO PERFORM THIS WORK.
  
 2- FLAT ROOF FL16717-R13 SUBMITTED.
 SELECTED ASSEMBLY W-107 ON PAGE 22 OF 87 DOESN'T MEET
 THE DESIGN PRESSURES FOR ALL ROOF ZONES. PROVIDE SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS AS REQUIRED BY LIMITATION
 5.7.2 ON PAGE 5 OF 5 OR SELECT ANOTHER ASSEMBLY THAT
 MEETS THE DESIGN PRESSURES FOR ALL ROOF ZONES.
  
 3- ROOF TILE NOA 22-0714.18 AND ROOF TILE ADHESIVE
 FL6332-R9 SUBMITTED: CLEARLY MARK ADHESIVE PADDY SIZE
 TO BE USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING
 PERMITS TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES
 OF SEC R301.2.1 FBC-RESIDENTIAL.
  
 4- TU PLUS FLORIDA PRODUCT APPROVAL FL-5259-R38
 SUBMITTED SAYS "PENDING FBC APPROVAL". NEED TO PROVIDE
 APPROVED PRODUCT APPROVAL.
 F.A.C. 61G20.3.001.
  
 5- HIP AND RIDGE TILE INSTALLATION. PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS FOR HIP AND RIDGE
 INSTALLATION AS REQUIRED BY SEC. R905.3.7.1
 FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS IN ACCORDANCE
 WITH FRSA/TRI FLORIDA HIGH WIND CONCRETE AND CLAY TILE
 INSTALLATION MANUAL (6TH EDITION) OR THE
 RECOMMENDATIONS OF RAS 118, 119 OR 120.
 ALTERNATIVE: IF USING METAL SUPPORT, THEN PROVIDE
 PRODUCT APPROVAL FOR HIP AND RIDGE METAL SUPPORT AND
 CLEARLY MARK ATTACHMENT METHOD.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-07-26 Cont ID  
Sent By jgomez Date 2023-07-26 Time 09:41 Rev Time 0.00
Received By jgomez Date 2023-07-25 Time 13:19 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-07-19 Cont ID  
Sent By jgomez Date 2023-07-19 Time 16:17 Rev Time 0.00
Received By jgomez Date 2023-07-17 Time 16:28 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-07-10 Cont ID  
Sent By jgomez Date 2023-07-10 Time 19:04 Rev Time 0.00
Received By jgomez Date 2023-07-06 Time 11:58 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-28 Cont ID  
Sent By jgomez Date 2023-06-28 Time 17:31 Rev Time 0.00
Received By jgomez Date 2023-06-20 Time 10:33 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-05 Cont ID  
Sent By jgomez Date 2023-06-05 Time 15:30 Rev Time 0.00
Received By jgomez Date 2023-06-02 Time 09:34 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-26 Cont ID  
Sent By jgomez Date 2023-05-26 Time 17:31 Rev Time 0.00
Received By jgomez Date 2023-05-24 Time 14:02 Sent To I
Notes
***NONE***