Plan Review Details - Permit 23051012
Plan Review Stops For Permit 23051012
Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-07-24 Cont ID  
Sent By jleahy Date 2023-07-24 Time 11:30 Rev Time 0.00
Received By jleahy Date 2023-07-24 Time 11:30 Sent To  
Notes
2023-07-24 11:38:05FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE 5-5.5 RISER SHOWS 1200 AMPERE BREAKERS FROM
 SERVICE AND GENERATOR FEEDING A 400 AMPERE TRANSFER
 SWITCH.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-06-30 Cont ID  
Sent By rperdomo Date 2023-06-30 Time 14:10 Rev Time 0.00
Received By rperdomo Date 2023-06-30 Time 13:28 Sent To  
Notes
2023-06-30 14:10:04FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE ATS SPECIFICATIONS. FBC 107.3.5
  
 2. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS
 TO BE LOW. WPB F.B.C. 109.3
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN P. PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-07-21 Cont ID  
Sent By clfranci Date 2023-07-21 Time   Rev Time 0.00
Received By clfranci Date 2023-07-21 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-06-27 Cont ID  
Sent By clfranci Date 2023-06-27 Time   Rev Time 0.00
Received By clfranci Date 2023-06-27 Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-07-20 Cont ID  
Sent By rwbrown Date 2023-07-20 Time 07:28 Rev Time 0.00
Received By rwbrown Date 2023-07-20 Time 07:28 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-06-26 Cont ID  
Sent By rwbrown Date 2023-06-26 Time 07:55 Rev Time 0.00
Received By rwbrown Date 2023-06-26 Time 07:55 Sent To  
Notes
2023-06-26 08:48:321ST GAS REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (13) - PLEASE SUBMIT THE
 GAS RISER THAT INCLUDES THE GAS LINE TO THE GENERATOR
 AS WELL AS THE SYSTEM TO THE BUILDING FOR REVIEW.
 INCLUDE THE MATERIALS USED, PIPE LENGHTS AND SIZING
 METHOD. INCLUDE THE LOCATION OF THE REGULATORS.
  
 2. 2017 WPB AMEND 107.3.5.3 (13) - ON A SITE PLAN, SHOW
 THE ROUTING OF THE GAS LINE FROM THE METER TO THE
 GENERATOR.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-19 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-14 Cont ID  
Sent By cmontell Date 2023-07-14 Time 13:50 Rev Time 0.00
Received By lmarchan Date 2023-07-11 Time 13:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-07-22 Cont ID  
Sent By cmontell Date 2023-07-22 Time 11:49 Rev Time 0.00
Received By cmontell Date 2023-07-22 Time 11:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-07-11 Cont ID  
Sent By cmontell Date 2023-07-11 Time 13:46 Rev Time 0.00
Received By cmontell Date 2023-07-11 Time 13:46 Sent To  
Notes
2023-07-11 13:48:06MECHANICAL PLAN REVIEW FAIL
  
 SHOW EXHAUST PER FBC SEC 107
  
 CHRIS MONTELLO
 561-805-6733

Review Stop P PLUMBING
Rev No 2 Status N Date 2023-07-20 Cont ID  
Sent By rwbrown Date 2023-07-20 Time 07:29 Rev Time 0.00
Received By rwbrown Date 2023-07-20 Time 07:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2023-06-26 Cont ID  
Sent By rwbrown Date 2023-06-26 Time 07:55 Rev Time 0.00
Received By rwbrown Date 2023-06-26 Time 07:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-11 Cont ID  
Sent By cmontell Date 2023-07-11 Time 13:52 Rev Time 0.00
Received By cmontell Date 2023-07-11 Time 13:52 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-07-14 Cont ID  
Sent By llouie Date 2023-07-14 Time   Rev Time  
Received By llouie Date 2023-07-14 Time   Sent To  
Notes
2023-07-14 13:48:19* SCOPE OF REVIEW IS FOR EMERGENCY GENERATOR ONLY.
  
 * REFERENCE: PB 1837D (PALM BEACH RIVERSTONE CPD).


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved