Plan Review Details - Permit 23050954
Plan Review Stops For Permit 23050954
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2023-06-14 Cont ID  
Sent By cpuell Date 2023-06-14 Time 09:02 Rev Time 0.00
Received By cpuell Date 2023-06-14 Time 09:02 Sent To  
Notes
2023-06-14 09:02:45100 WORTH CT S WAS REQUESTED FOR THE SITE, ADDRESSING
 IS ABLE TO ACCOMMODATE THIS, UPDATED PERMIT TO REFLECT
 NEW ADDRESS. PLEASE ENSURE THAT THIS ADDRESSES IS
 REFLECTED ON ANY SHEETS THAT ARE RESUBMITTED.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2023-05-27 Cont ID  
Sent By cpuell Date 2023-05-27 Time 09:14 Rev Time 0.00
Received By cpuell Date 2023-05-27 Time 09:14 Sent To  
Notes
2023-05-27 09:15:27PARCEL NEEDS TO BE READDRESSED SO THAT THE ENTRANCES ON
 THE GROUND FLOOR FALLS IN LINE WITH THE CITY'S ROAD
 CENTER LINES. FLAGLER DR ADDRESS NOT APPROPRIATE FOR
 THIS PARCEL, A WORTH CT S ADDRESS WILL NEED TO BE
 ESTABLISHED. PLEASE CONTACT [email protected] OR CALL
 561-805-6659 TO WORK ON THE READDRESSING ISSUES.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-05-18 Cont ID  
Sent By cpuell Date 2023-05-18 Time 06:58 Rev Time 0.00
Received By cpuell Date 2023-05-18 Time 06:58 Sent To  
Notes
2023-05-18 07:01:13THIS REVIEW IS ONLY REGARDING THE OWNER ON THE
 APPLICATION FORM, THE ADDRESSING REVIEW WILL BE DONE
 ONCE PLANS ARE SUBMITTED.
  
 PLEASE PROVIDE A WARRANTY DEED SO THAT WE CAN UPDATE
 THE OWNER INFORMATION, THE OWNER ON THE APPLICATION
 FORM DOES NOT MATCH THE OWNER INFORMATION ON THE PBC
 PROPERTY APPRAISERS, IF THIS WAS A MISTAKE PLEASE
 RESUBMIT THE APPLICATION FORM WITH THE CORRECT OWNER OR
 EMAIL DEED TO [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-27 Cont ID  
Sent By cthroop Date 2023-05-27 Time 09:34 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:23 Sent To  
Notes
2023-05-25 15:40:551ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 PROVISO ON PLAN PAGE SP1.01: A SEPERATE PERMIT IS
 REQUIRED FOR THE GENERATOR. CT
  
 PROVISO ON PLAN PAGE E1.01: A SEPERATE PERMIT IS
 REQUIRED FOR HURRICANE SCREENS. CT
  
 NOTICE:
 SUB-PERMITS REQUIRED FOR M/E/P/GAS
 105.1 REQUIRED.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
  
 1. APPROVAL OF THE CONSTRUCTION DRAWING ELEVATION
 CERETIFICATE IS REQUIRED PRIOR TO APPORVAL OF THE
 BUILDING REVIEW.
 SEE COMMENTS UNDER THE NFIP REVIEW.
  
 2. PLAN PAGE A1.10 STATES 6 SMART VENTS, MODEL 1540-520
 WILL BE INSTALLED WITH 2 VENTS PER LOCATION. PROVIDE
 LOCATION AND ORIENTATION OF VENTS ON THE ARCHITECTURAL
 ELEVATION PLANS.
 IF THE ORIENTATION IS VERTICAL, CONSIDER USING SMART
 VENT MODEL 1540-521 - STACKABLE. (400SF/VENT)
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 3. PROVIDE THE MANUFACTURERS SPECIFICATIONS FOR THE
 ELEVATOR.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-05-27 Cont ID  
Sent By cthroop Date 2023-05-27 Time 09:36 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:23 Sent To  
Notes
2023-05-24 13:24:351ST ELECTRICAL REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE:
 ELECTRICAL SUB-PERMIT REQUIRED
 105.1 REQUIRED.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 1. IDENTIFY LOCATION OF PANEL "P". (POOL)
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-05-27 Cont ID  
Sent By cthroop Date 2023-05-27 Time 09:06 Rev Time 0.00
Received By cthroop Date 2023-05-26 Time 14:09 Sent To  
Notes
2023-05-26 14:09:49 
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status   Date   Cont ID  
Sent By parking Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-05-26 Cont ID  
Sent By cthroop Date 2023-05-26 Time 11:09 Rev Time 0.00
Received By cthroop Date 2023-05-26 Time 08:44 Sent To  
Notes
2023-05-26 10:38:431ST FUEL GAS REVIEW
 RESULTS: CORRECTIONS ARE NEEDED
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2014 NEC
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE:
 FUEL GAS SUB-PERMIT REQUIRED
 105.1 REQUIRED.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE
 LENGTH OF ALL CUT SECTIONS OF PIPE PER 2020 FBC FUEL
 GAS, SECS. 402.4.1, 402.4.2. OR 2020 FBC FUEL GAS RES
 SECS. G2413.4.1, G2413.4.2.
  
 2. SUBMIT APPLICABLE GAS TABLES.
  
 3. SUBMIT MANUFACTURERS SPECIFICATION
 SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO
 VERIFY COMPLIANCE WITH 2020 FBC FUEL GAS SEC.305.1 OR
 2020 FBC FUEL GAS RES. SEC. G2408.1.
  
 4. SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS.
 A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY
 AHEAD OF EACH MP REGULATOR. 2017 FBC FG SEC. 409.4,
 2017 FBC RES. SEC. G2420.4.
 SUBMIT GAS REGULATOR SPECIFICATIONS. 2020 FBC FUEL GAS
 SEC.305.1 OR 2020 FBC FUEL GAS RES. SEC. G2408.1.
  
 5. REGULATORS SHALL HAVE A UNION INSTALLED WITHIN 1
 FOOT OF EITHER SIDE OF THE REGULATOR FBC FG 410.2
  
 6. SUBMIT A COPY OF A HOUSE PLAN SHOWING THE LOCATION
 OF ALL PROPOSED GAS APPLIANCES. WPB AMENDMENTS TO THE
 FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-15 Cont ID  
Sent By jleahy Date 2023-06-15 Time 11:55 Rev Time 0.00
Received By avolcy Date 2023-05-24 Time 13:03 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-05-25 Cont ID  
Sent By cthroop Date 2023-05-25 Time 12:34 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:23 Sent To  
Notes
2023-05-25 12:35:07IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-05-27 Cont ID  
Sent By cthroop Date 2023-05-27 Time 09:06 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:23 Sent To  
Notes
2023-05-24 13:24:491ST MECHANICAL REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE:
 MECHANICAL SUB-PERMIT REQUIRED
 105.1 REQUIRED.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 AHU IN ATTICS
 1. M1305.1.3.1 ELECTRICAL REQUIREMENTS.
 A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE
 REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET
 SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN
 ACCORDANCE WITH CHAPTER 39. EXPOSED LAMPS SHALL BE
 PROTECTED FROM DAMAGE BY LOCATION OR LAMP GUARDS.
  
 2. EQUIPMENT SERVICE OUTLET:
 E3901.12 HVAC OUTLET.
 A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED
 RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE
 LOCATION FOR THE SERVICING OF HEATING, AIR-CONDITIONING
 AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE
 LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET (7620 MM)
 OF THE HEATING, AIR-CONDITIONING AND REFRIGERATION
 EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE CONNECTED
 TO THE LOAD SIDE OF THE HVAC EQUIPMENT DISCONNECTING
 MEANS. (210.63)
  
 3. M1411.8 LOCKING ACCESS PORT CAPS.
 REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL
 BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS OR
 SHALL BE OTHERWISE SECURED TO PREVENT UNAUTHORIZED
 ACCESS.
  
  
  
  
  
  
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2023-05-25 Cont ID  
Sent By cthroop Date 2023-05-25 Time 17:08 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:54 Sent To  
Notes
2023-05-25 17:19:491ST NFIP REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS
 SITE IS AE 7 WITH A BASE FLOOD ELEVATION (BFE) OF
 7???0??? NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9???0??? NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 1ST REVIEW OF THE CONSTRUCTION DRAWING ELEVATION
 CERTIFICATE:
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. LINES A8 B) & C) - USE N/A PER EC INSTRUCTIONS.
  
 2. LINE B2 - PROPERTY IS LOCATED IN PALM BEACH COUNTY.
  
 3. LINE B3 - USE THE 2-LETTER ABBREVIATION (FL) FOR THE
 STATE PER EC INSTRUCTIONS.
  
 4. LINE C2 A) - 9.5' (SEE PLAN PAGE A2.01)
  
 5. LINE C2 B) - 22.0' (SEE PLAN PAGE A2.01)
  
 6. SECTION D COMMENTS - IDENTIFY TYPE AND MODEL OF
 SMART VENTS REFERENCED ON LINE A9 D) - SMART VENT MODEL
 1540-520.
  
 NOTICE: ADDITIONAL ELEVATION CERTIFICATES ARE REQUIRED.
 SEE BELOW:
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-05-27 Cont ID  
Sent By cthroop Date 2023-05-27 Time 08:50 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:23 Sent To  
Notes
2023-05-24 13:25:01 
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2023-05-25 Cont ID  
Sent By cthroop Date 2023-05-25 Time 15:41 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:23 Sent To  
Notes
2023-05-25 15:46:40PLAN REVIEW ROOFING
  
 1ST ROOFING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: A ROOFING SUB-PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER
 BARRIER PER FBC R905.1.1.
 UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL
 CONFORM TO THE APPLICABLE STANDARDS??? AND SHALL BE
 APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION
 R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE.
  
 2. NOA 19-1021.25 CEMENT TILE HAS EXPIRED.
 3. NOA'S 17-0322.03 & 17-0725.10 ARE MISSING.
 PROVIDE THE PRODUCT APPROVALS FOR PROPOSED ROOF
 COVERINGS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-25 Cont ID  
Sent By cthroop Date 2023-05-25 Time 13:59 Rev Time 0.00
Received By cthroop Date 2023-05-24 Time 13:24 Sent To  
Notes
2023-05-25 14:00:36ALL PLAN PAGES INCLUDING SURVEY AND ELEVATION
 CERTIFICATE. CT

Review Stop Z ZONING
Rev No 1 Status F Date 2023-06-15 Cont ID  
Sent By avolcy Date 2023-06-15 Time 11:54 Rev Time 0.00
Received By avolcy Date 2023-06-15 Time 11:54 Sent To  
Notes
2023-06-15 11:55:47FAILED
  
 PER ZONING AND LAND DEVELOPMENT REGULATION SECTION
 94-72(A)(1)(D), FLAGLER DRIVE IS CONSIDERED THE FRONT
 OF THE PROPERTY, THEREFORE, THE PROPOSED LOGGIA IS
 ENCROACHING INTO THE FRONT SETBACK.
 THE NORTH PROPERTY LINE IS THE ???CORNER;??? THE SOUTH
 IS THE ???SIDE;??? EAST IS THE FRONT; AND WEST IS THE
 ???REAR.??? UPDATE PLANS AND SURVEY TO REFLECT THE
 APPROPRIATE SETBACKS FOR THE PRINCIPAL STRUCTURE. PER
 ZLDR SECTION 94-72(A)(2) THE MINIMUM SETBACKS FOR THE
 PRINCIPAL BUILDING ARE AS FOLLOWS - FRONT: 25 FEET;
 CORNER: 12.5 FEET; REAR: 15 FEET OR TEN PERCENT OF LOT
 DEPTH, WHICHEVER IS LESS; SIDE: FIVE FEET MINIMUM, 15
 FEET TOTAL.
  
 POOL/MECHANICAL EQUIPMENT CANNOT ENCROACH MORE THAN 4FT
 INTO REQUIRED SETBACK.
  
 SEPARATE PERMIT REQUIRED FOR:
 FENCE/WALL, DRIVEWAY, POOL, GENERATOR,
 MECHANICAL/AC/POOL EQUIPMENT, IRRIGATION, LANDSCAPE,
 ACCESSORY STRUCTURE, ETC.
  
 **** REVIEWED BY ****
 ANNE VOLCY
 PLANNER
 [email protected]
  