| Plan Review Stops For Permit 23050954 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-06-14 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-06-14 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2023-06-14 09:02:45 | 100 WORTH CT S WAS REQUESTED FOR THE SITE, ADDRESSING | | | IS ABLE TO ACCOMMODATE THIS, UPDATED PERMIT TO REFLECT | | | NEW ADDRESS. PLEASE ENSURE THAT THIS ADDRESSES IS | | | REFLECTED ON ANY SHEETS THAT ARE RESUBMITTED. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2023-05-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-05-27 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-05-27 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2023-05-27 09:15:27 | PARCEL NEEDS TO BE READDRESSED SO THAT THE ENTRANCES ON | | | THE GROUND FLOOR FALLS IN LINE WITH THE CITY'S ROAD | | | CENTER LINES. FLAGLER DR ADDRESS NOT APPROPRIATE FOR | | | THIS PARCEL, A WORTH CT S ADDRESS WILL NEED TO BE | | | ESTABLISHED. PLEASE CONTACT [email protected] OR CALL | | | 561-805-6659 TO WORK ON THE READDRESSING ISSUES. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-18 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-05-18 |
Time |
06:58 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-05-18 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2023-05-18 07:01:13 | THIS REVIEW IS ONLY REGARDING THE OWNER ON THE | | | APPLICATION FORM, THE ADDRESSING REVIEW WILL BE DONE | | | ONCE PLANS ARE SUBMITTED. | | | | | | PLEASE PROVIDE A WARRANTY DEED SO THAT WE CAN UPDATE | | | THE OWNER INFORMATION, THE OWNER ON THE APPLICATION | | | FORM DOES NOT MATCH THE OWNER INFORMATION ON THE PBC | | | PROPERTY APPRAISERS, IF THIS WAS A MISTAKE PLEASE | | | RESUBMIT THE APPLICATION FORM WITH THE CORRECT OWNER OR | | | EMAIL DEED TO [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-27 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2023-05-25 15:40:55 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | PROVISO ON PLAN PAGE SP1.01: A SEPERATE PERMIT IS | | | REQUIRED FOR THE GENERATOR. CT | | | | | | PROVISO ON PLAN PAGE E1.01: A SEPERATE PERMIT IS | | | REQUIRED FOR HURRICANE SCREENS. CT | | | | | | NOTICE: | | | SUB-PERMITS REQUIRED FOR M/E/P/GAS | | | 105.1 REQUIRED. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | | | | 1. APPROVAL OF THE CONSTRUCTION DRAWING ELEVATION | | | CERETIFICATE IS REQUIRED PRIOR TO APPORVAL OF THE | | | BUILDING REVIEW. | | | SEE COMMENTS UNDER THE NFIP REVIEW. | | | | | | 2. PLAN PAGE A1.10 STATES 6 SMART VENTS, MODEL 1540-520 | | | WILL BE INSTALLED WITH 2 VENTS PER LOCATION. PROVIDE | | | LOCATION AND ORIENTATION OF VENTS ON THE ARCHITECTURAL | | | ELEVATION PLANS. | | | IF THE ORIENTATION IS VERTICAL, CONSIDER USING SMART | | | VENT MODEL 1540-521 - STACKABLE. (400SF/VENT) | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 3. PROVIDE THE MANUFACTURERS SPECIFICATIONS FOR THE | | | ELEVATOR. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-27 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2023-05-24 13:24:35 | 1ST ELECTRICAL REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: | | | ELECTRICAL SUB-PERMIT REQUIRED | | | 105.1 REQUIRED. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 1. IDENTIFY LOCATION OF PANEL "P". (POOL) | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
E-LOWVOLT |
ELECTRICAL LOW VOLTAGE |
| Rev No |
1 |
Status |
P |
Date |
2023-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-27 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-26 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
parking |
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-26 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-26 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2023-05-26 10:38:43 | 1ST FUEL GAS REVIEW | | | RESULTS: CORRECTIONS ARE NEEDED | | | | | | CHRISTOPHER S. THROOP, C.B.O., CFM | | | PLANS EXAMINER II PX3169/SFP306 | | | INSPECTOR BN4338 | | | BUILDING OFFICIAL BU1635 | | | ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 | | | DEVELOPMENT SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | 2014 NEC | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | NOTICE: | | | FUEL GAS SUB-PERMIT REQUIRED | | | 105.1 REQUIRED. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS THE | | | LENGTH OF ALL CUT SECTIONS OF PIPE PER 2020 FBC FUEL | | | GAS, SECS. 402.4.1, 402.4.2. OR 2020 FBC FUEL GAS RES | | | SECS. G2413.4.1, G2413.4.2. | | | | | | 2. SUBMIT APPLICABLE GAS TABLES. | | | | | | 3. SUBMIT MANUFACTURERS SPECIFICATION | | | SHEETS/INSTALLATION MANUAL FOR ALL GAS EQUIPMENT TO | | | VERIFY COMPLIANCE WITH 2020 FBC FUEL GAS SEC.305.1 OR | | | 2020 FBC FUEL GAS RES. SEC. G2408.1. | | | | | | 4. SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS. | | | A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY | | | AHEAD OF EACH MP REGULATOR. 2017 FBC FG SEC. 409.4, | | | 2017 FBC RES. SEC. G2420.4. | | | SUBMIT GAS REGULATOR SPECIFICATIONS. 2020 FBC FUEL GAS | | | SEC.305.1 OR 2020 FBC FUEL GAS RES. SEC. G2408.1. | | | | | | 5. REGULATORS SHALL HAVE A UNION INSTALLED WITHIN 1 | | | FOOT OF EITHER SIDE OF THE REGULATOR FBC FG 410.2 | | | | | | 6. SUBMIT A COPY OF A HOUSE PLAN SHOWING THE LOCATION | | | OF ALL PROPOSED GAS APPLIANCES. WPB AMENDMENTS TO THE | | | FBC SEC. 107.2.1. INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-06-15 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-05-24 |
Time |
13:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-25 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2023-05-25 12:35:07 | IMPACT FEES | | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-27 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2023-05-24 13:24:49 | 1ST MECHANICAL REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: | | | MECHANICAL SUB-PERMIT REQUIRED | | | 105.1 REQUIRED. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | AHU IN ATTICS | | | 1. M1305.1.3.1 ELECTRICAL REQUIREMENTS. | | | A LUMINAIRE CONTROLLED BY A SWITCH LOCATED AT THE | | | REQUIRED PASSAGEWAY OPENING AND A RECEPTACLE OUTLET | | | SHALL BE INSTALLED AT OR NEAR THE APPLIANCE LOCATION IN | | | ACCORDANCE WITH CHAPTER 39. EXPOSED LAMPS SHALL BE | | | PROTECTED FROM DAMAGE BY LOCATION OR LAMP GUARDS. | | | | | | 2. EQUIPMENT SERVICE OUTLET: | | | E3901.12 HVAC OUTLET. | | | A 125-VOLT, SINGLE-PHASE, 15- OR 20-AMPERE-RATED | | | RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE | | | LOCATION FOR THE SERVICING OF HEATING, AIR-CONDITIONING | | | AND REFRIGERATION EQUIPMENT. THE RECEPTACLE SHALL BE | | | LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET (7620 MM) | | | OF THE HEATING, AIR-CONDITIONING AND REFRIGERATION | | | EQUIPMENT. THE RECEPTACLE OUTLET SHALL NOT BE CONNECTED | | | TO THE LOAD SIDE OF THE HVAC EQUIPMENT DISCONNECTING | | | MEANS. (210.63) | | | | | | 3. M1411.8 LOCKING ACCESS PORT CAPS. | | | REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL | | | BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS OR | | | SHALL BE OTHERWISE SECURED TO PREVENT UNAUTHORIZED | | | ACCESS. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-25 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2023-05-25 17:19:49 | 1ST NFIP REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | FEMA DESK REFERENCE P 758 | | | FBC R322 FLOOD-RESISTANT CONSTRUCTION | | | | | | NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS | | | SITE IS AE 7 WITH A BASE FLOOD ELEVATION (BFE) OF | | | 7???0??? NAVD. | | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 9???0??? NAVD. | | | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | | SHALL READ AS FOLLOWS: | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE, RESIDENTIAL. | | | R322.2.1 ELEVATION REQUIREMENTS. | | | 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | | PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | | IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17). | | | | | | 1ST REVIEW OF THE CONSTRUCTION DRAWING ELEVATION | | | CERTIFICATE: | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. LINES A8 B) & C) - USE N/A PER EC INSTRUCTIONS. | | | | | | 2. LINE B2 - PROPERTY IS LOCATED IN PALM BEACH COUNTY. | | | | | | 3. LINE B3 - USE THE 2-LETTER ABBREVIATION (FL) FOR THE | | | STATE PER EC INSTRUCTIONS. | | | | | | 4. LINE C2 A) - 9.5' (SEE PLAN PAGE A2.01) | | | | | | 5. LINE C2 B) - 22.0' (SEE PLAN PAGE A2.01) | | | | | | 6. SECTION D COMMENTS - IDENTIFY TYPE AND MODEL OF | | | SMART VENTS REFERENCED ON LINE A9 D) - SMART VENT MODEL | | | 1540-520. | | | | | | NOTICE: ADDITIONAL ELEVATION CERTIFICATES ARE REQUIRED. | | | SEE BELOW: | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-05-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-27 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-25 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2023-05-25 15:46:40 | PLAN REVIEW ROOFING | | | | | | 1ST ROOFING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: A ROOFING SUB-PERMIT REQUIRED. | | | PERMITS - 105.1 REQUIRED. | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER | | | BARRIER PER FBC R905.1.1. | | | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL | | | CONFORM TO THE APPLICABLE STANDARDS??? AND SHALL BE | | | APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION | | | R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE. | | | | | | 2. NOA 19-1021.25 CEMENT TILE HAS EXPIRED. | | | 3. NOA'S 17-0322.03 & 17-0725.10 ARE MISSING. | | | PROVIDE THE PRODUCT APPROVALS FOR PROPOSED ROOF | | | COVERINGS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-25 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2023-05-25 14:00:36 | ALL PLAN PAGES INCLUDING SURVEY AND ELEVATION | | | CERTIFICATE. CT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-15 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-06-15 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-06-15 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2023-06-15 11:55:47 | FAILED | | | | | | PER ZONING AND LAND DEVELOPMENT REGULATION SECTION | | | 94-72(A)(1)(D), FLAGLER DRIVE IS CONSIDERED THE FRONT | | | OF THE PROPERTY, THEREFORE, THE PROPOSED LOGGIA IS | | | ENCROACHING INTO THE FRONT SETBACK. | | | THE NORTH PROPERTY LINE IS THE ???CORNER;??? THE SOUTH | | | IS THE ???SIDE;??? EAST IS THE FRONT; AND WEST IS THE | | | ???REAR.??? UPDATE PLANS AND SURVEY TO REFLECT THE | | | APPROPRIATE SETBACKS FOR THE PRINCIPAL STRUCTURE. PER | | | ZLDR SECTION 94-72(A)(2) THE MINIMUM SETBACKS FOR THE | | | PRINCIPAL BUILDING ARE AS FOLLOWS - FRONT: 25 FEET; | | | CORNER: 12.5 FEET; REAR: 15 FEET OR TEN PERCENT OF LOT | | | DEPTH, WHICHEVER IS LESS; SIDE: FIVE FEET MINIMUM, 15 | | | FEET TOTAL. | | | | | | POOL/MECHANICAL EQUIPMENT CANNOT ENCROACH MORE THAN 4FT | | | INTO REQUIRED SETBACK. | | | | | | SEPARATE PERMIT REQUIRED FOR: | | | FENCE/WALL, DRIVEWAY, POOL, GENERATOR, | | | MECHANICAL/AC/POOL EQUIPMENT, IRRIGATION, LANDSCAPE, | | | ACCESSORY STRUCTURE, ETC. | | | | | | **** REVIEWED BY **** | | | ANNE VOLCY | | | PLANNER | | | [email protected] | | | |
|
|