| Plan Review Stops For Permit 23050903 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-12 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-12 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-13 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-06-13 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-10 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-07 |
Time |
16:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-06-02 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-06-02 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-06-02 |
Time |
12:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-03 |
Time |
11:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-14 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-14 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-12 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-12 |
Time |
16:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-14 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-14 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-05 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-05 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-26 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-26 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2023-05-26 13:44:07 | FBC-2020 RES. PLUMBING | | | PERMIT- 23050903 | | | 5/26/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P104: PLEASE REMOVE THE GREASE INTERCEPTOR | | | FROM THE DRAWING. THIS PROPOSED PROJECT IS AN ADDITION | | | TO A SINGLE-FAMILY RESIDENTIAL HOME AND GREASE | | | INTERCEPTORS ARE NOT REQUIRED PER SEC. R101.2 FBC RES. | | | CODE & SEC. 90-125(7) WPB CODE OF ORDINANCES. IF THE | | | INTENTION IS TO CHANGE THE OCCUPANCY OF THE HOME AT A | | | LATER DATE AND INSTALL A GREASE INTERCEPTOR, THEN BOTH | | | THE CHANGE OF OCCUPANCY AND THE GREASE INTERCEPTOR | | | SHALL BE DONE UNDER SEPARATE PERMITS AND COMPLETE PLANS | | | AND SPECIFICATIONS SHALL BE PROVIDED FOR DEVELOPMENT | | | SERVICE DEPARTMENT REVIEW. PLEASE NOTE THE CURRENT PLAN | | | SHOWS THE SANITARY SEWER LINE FROM THE DOMESTIC | | | HOUSEHOLD FIXTURES DRAINING INTO THE GREASE INTERCEPTOR | | | WHICH IS PROHIBITED PER SEC. 1003.3.1 FBC P. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-12 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-12 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2023-07-05 12:16:55 | PLUMBING PLAN SIGS PASSED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-13 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-06-13 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2023-06-06 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2023-06-06 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2023-06-06 10:16:42 | 6/6/23- FAILED. PLANS SHOW MORE THAN ONE KITCHENS. IN | | | AN SF7 ZONING DISTRICT ONLY ONE KITCHEN IS ALLOWED. | | | | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] |
|
|