Plan Review Details - Permit 23050885
| Plan Review Stops For Permit 23050885 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-21 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-21 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-08 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-08 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2023-06-08 15:00:58 | EXTERIOR RENOVATION | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE SHOW THE ADDED WOOD SIDING DETAILS WALL | | | WEATHER RESISTANCE, SIDING ATTACHMENTS ETC. - FBC 1609 | | | AND 1403.2 | | | | | | 2) THE WINDOW AND DOOR ENGINEERING NEEDS TO BE SIGNED | | | BY THOMAS TWOMEY P.E. - SIGNED AND SEALED DRAWINGS IN | | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE). |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-06-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-06-21 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2023-06-21 12:22:16 | FIRE PROVISO: | | | | | | ACCESS CONTROL SHALL BE INSTALLED AND INSPECTED UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS | | | | | | EXIT HARDWARE SHALL BE AS REQUIRED UNDER NFPA 101, | | | MEANS OF EGRESS INCLUDING PUSH BAS, LOCKS & LATCHES. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-22 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2023-05-22 11:48:00 | FIRE PROVISO: | | | | | | ACCESS CONTROL SHALL BE INSTALLED AND INSPECTED UNDER | | | SEPARATE PERMIT AND SHOP DRAWINGS | | | | | | EXIT HARDWARE SHALL BE AS REQUIRED UNDER NFPA 101, | | | MEANS OF EGRESS INCLUDING PUSH BAS, LOCKS & LATCHES. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-21 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-16 |
Time |
09:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-08 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-18 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-21 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-21 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-08 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-08 |
Time |
15:01 |
Sent To |
|
|
| Notes |
| 2023-06-08 15:02:00 | SIGNATURE REVI | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE WINDOW AND DOOR ENGINEERING NEEDS TO BE SIGNED | | | BY THOMAS TWOMEY P.E. - SIGNED AND SEALED DRAWINGS IN | | | PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED | | | TO BE USED IN ELECTRONIC PLAN REVIEW. (A | | | CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED | | | A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF | | | E-SIGNATURE). |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-06-27 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-06-27 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |