| 2023-05-18 13:31:44 | RE-ROOF BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #23050878 |
| | 710 EXECUTIVE CTR DR |
| | CLUBHOUSE |
| | |
| | NOTE: |
| | LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING. |
| | SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL |
| | COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN |
| | THE FLORIDA BUILDING CODE. |
| | |
| | |
| | 1- ROOF TO WALL CONNECTIONS: |
| | THE BUILDING HAS A VALUATION OF MORE THAN $300,000. |
| | NEED TO COMPLY WITH THE ROOF TO WALL CONNECTIONS AS |
| | REQUIRED BY SEC. 706.8 FBC-EXISTING BUILDING. |
| | STORM ROOFING, INC LETTER SUBMITTED IS NOT ACCEPTABLE. |
| | THE ESTIMATE FOR THE ROOF TO WALL EVALUATION AND |
| | INSTALLATION OF CONNECTIONS AT GABLE ENDS OR ALL |
| | CORNERS HAS TO BE DONE BY LICENSED GENERAL OR BUILDING |
| | CONTRACTOR NOT BY ROOFING CONTRACTOR. |
| | ANOTHER OPTION IS TO SHOW THAT THE EXISTING ROOF TO |
| | WALL CONNECTIONS MEET OR EXCEED FLORIDA BUILDING CODE. |
| | |
| | 2- PERMIT APPLICATION AND SUPPORTING DOCUMENTS CALL FOR |
| | REROOF OF SHINGLES ONLY. BASED ON AERIAL VIEW OF THE |
| | BUILDING, THERE IS A FLAT ROOF ON TOP OF THE ROOF. |
| | CLARIFY WHY THIS FLAT ROOF IS NOT GOING TO BE DONE. IF |
| | FLAT ROOF IS GOING TO BE REPLACED, THEN THE TYPICAL |
| | COMMENTS FOR ALL OTHER BUILDINGS WILL APPLY FOR THE |
| | FLAT ROOF PRODUCT APPROVAL. SEE COPY OF COMMENTS FOR |
| | THOSE BUILDINGS BELOW. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |