| Plan Review Stops For Permit 23050829 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2023-07-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-07-20 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-07-20 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2023-07-20 15:38:46 | 7/20/23 - THE LETTER IS NOT SIGNED BY THE QUALIFIER. | | | PLEASE PROVIDE A SIGNED ASBESTOS LETTER FROM THE | | | QUALIFIER. | | | | | | | | | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23050829 | | | | | | REVIEWED: .6.20.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | ASBESTOS PLAN REVIEW: FAILED | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING: | | | | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-05 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-05 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2023-07-05 08:47:14 | PREVIOUS COMMENT NOT ANSWERED |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-20 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-20 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2023-06-20 14:07:11 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23050829 | | | | | | REVIEWED: .6.20.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | ASBESTOS PLAN REVIEW: FAILED | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING: | | | | | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-05 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-05 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-20 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-20 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-07-13 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-07-13 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-06-15 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-06-15 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-06-15 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2023-06-15 13:28:59 | ELECTRIC REVIEW FAILED | | | | | | 1) PLEASE PROVIDE A DETAILED ELECTRIC FLOOR PLAN AND | | | WORK SCOPE DETAILING ALL NEW ELECTRIC WORK. PLEASE | | | INCLUDE ALL REQUIRED NEW ELECTRIC ITEMS IF NOT EXISTING | | | SUCH AS SMOKE ALARMS KITCHEN RECEPTACLES AND | | | INDICATIONS OF ARC FAULT, GFIC PROTECTION AND TAMPER | | | RESISTANT DEVICES WHERE REQUIRED. FBC 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
clfranci |
Date |
2023-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
clfranci |
Date |
2023-07-06 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
clfranci |
Date |
2023-06-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
clfranci |
Date |
2023-06-08 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-06-08 12:55:44 | | | | THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L FRANCIS, | | | FIRE INVESTIGATOR, WITH THE FOLLOWING COMMENTS: | | | THERE ARE INDICATIONS OF INSTALLATION OF NEW FLOORING | | | BUT NO SPECIFICATIONS SHEETS THAT INDICATE MEETING THE | | | REQUIREMENTS PER NFPA' | | | | | | PER NFPA 101, CH 10 | | | | | | | | | SECTION 10.2. | | | | | | 10.2.7* INTERIOR FLOOR FINISH TESTING AND | | | CLASSIFICATION. | | | 10.2.7.1* CARPET AND CARPET LIKE INTERIOR FLOOR | | | FINISHES SHALL | | | COMPLY WITH ASTM D 2859, STANDARD TEST METHOD FOR | | | IGNITION | | | CHARACTERISTICS OF FINISHED TEXTILE FLOOR COVERING | | | MATERIALS. | | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | | 10.2.2.2 | | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | | HAVE A | | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | | | 10.2.7.4 INTERIOR FLOOR FINISHES SHALL BE GROUPED IN | | | THE CLASSES SPECIFIED | | | IN 10.2.7.4.1 AND 10.2.7.4.2 IN ACCORDANCE WITH THE | | | CRITICAL RADIANT FLUX | | | REQUIREMENTS. | | | 10.2.7.4.1 CLASS I INTERIOR FLOOR FINISH. CLASS I | | | INTERIOR FLOOR FINISH | | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | | 0.45 W/CM2, AS DETERMINED | | | BY THE TEST DESCRIBED IN 10.2.7.3. | | | 10.2.7.4.2 CLASS II INTERIOR FLOOR FINISH. CLASS II | | | INTERIOR FLOOR FINISH | | | SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN | | | 0.22 W/CM2, BUT LESS | | | THAN 0.45 W/CM2, AS DETERMINED BY THE TEST DESCRIBED IN | | | 10.2.7.3. | | | | | | PLEASE REVIEW AND PROVIDE SPEC SHEETS. | | | | | | | | | 2) THERE ARE INDICATIONS OF WALL AND VANITY REPLACEMENT | | | AND PAINTING. | | | | | | ANY WORK INVOLVING FIRE SPRINKLERS/FIRE ALARM SYSTEMS | | | OR EQUIPMENT SHALL BE DONE UNDER SEPARATE PERMITS AND | | | SHOP DRAWINGS. | | | | | | FIRE SPRINKLERS AND FIRE ALARM EQUIPMENT SHALL BE | | | PROTECTED FROM PAINTING OR DAMAGE. | | | | | | THE FIRE SPRINKLER/FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO AND RECONSTRUCTION. | | | | | | PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT AND ENSURE | | | COMPLIANCE. | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | CAITLIN L FRANCIS | | | FIRE INVESTIGATOR | | | 561-804-4728 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-18 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-07-03 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-26 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-26 |
Time |
13:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-20 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-20 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2023-07-18 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2023-07-18 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-26 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-26 |
Time |
13:16 |
Sent To |
|
|
| Notes |
| 2023-06-26 13:17:21 | NEED MECHANICAL PLAN FBC SEC 107 | | | | | | CHRIS MONTELLO | | | 561-805-6733 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-05 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-05 |
Time |
12:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-14 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-14 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2023-06-14 15:30:35 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT-23050829 | | | 6/14/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 3 OF 5 WHICH SHOWS THE SCOPE OF WORK FOR | | | PLUMBING REQUIRES THE PRINTED NAME AND SIGNATURE OF THE | | | CONTRACTOR OR QUALIFIER WHO DREW THE PLAN- SEC. 107.2.1 | | | WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-05 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-05 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-20 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-20 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|