| Plan Review Stops For Permit 23050674 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-25 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-25 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2023-07-25 11:38:03 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R39 | | | COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECTED | | | ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.2 | | | MECHANICALLY-ATTACHED BASE SHEET TABLE 4B ALLOWABLE | | | DESIGN PRESSURES, 2-PLY UNDERLAYMENT SYSTEMS IN TILE | | | ROOF APPLICATIONS; SELECTED SYSTEM NO. UDL-13 DO NOT | | | MEET OR EXCEED THE MINIMUM DESIGN PRESSURE REQUIREMENTS | | | FOR A HIP ROOF; (6:12) ROOF SLOPE; MEAN ROOF HEIGHT 15 | | | FT. MINIMUM DESIGN PRESSURE REQUIREMENT OF -70 IN AN | | | EXPOSURE CATEGORY C AREA. PROVIDE UNDERLAYMENT SYSTEM | | | THAT MEETS OR EXCEEDS THE ABOVE CRITERIA. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-18 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-18 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2023-07-18 13:49:03 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R38 | | | HAS BEEN REVISED TO FL5259-R39. PLEASE PROVIDE A | | | COMPLETE SET TO INCLUDE COVER PAGE(S); IT COVERS | | | MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; ALLOWABLE | | | UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE | | | SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS | | | FROM EACH CATEGORY TO BE USED; SELECT FROM TABLE 4A | | | DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS | | | OR TABLE 4B 2-PLY UNDERLAYMENT SYSTEMS IN TILE ROOF | | | APPLICATIONS. ALL APPLICABLE DETAILS AND ATTACHMENTS | | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | | DRAWINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-22 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-22 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2023-06-22 14:49:53 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R39 | | | COVERS MULTIPLE ATTACHMENT LIMITATIONS. SELECTED | | | ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.2 | | | MECHANICALLY-ATTACHED BASE SHEET TABLE 4A ALLOWABLE | | | DESIGN PRESSURES, DIRECT-TO-DECK UNDERLAYMENT IN TILE | | | ROOF APPLICATIONS SYSTEM NO. UDL-2 DO NOT ALLOW FOR THE | | | USE OF 30# FELT AS A BASE PLY. SELECT A SYSTEM THAT | | | MEETS THIS REQUIREMENT OR SELECT A 2-PLY UNDERLAYMENT | | | SYSTEM FROM TABLE 4B. ALL APPLICABLE DETAILS AND | | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | | APPROVAL DRAWINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-08 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-08 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2023-06-08 14:04:05 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 | | | HAS BEEN REVISED TO FL5259-R38. PLEASE PROVIDE A | | | COMPLETE SET TO INCLUDE COVER PAGE(S); IT COVERS | | | MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; ALLOWABLE | | | UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE | | | SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS | | | FROM EACH CATEGORY TO BE USED; SELECT FROM TABLE 4A | | | DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS | | | OR TABLE 4B 2-PLY UNDERLAYMENT SYSTEMS IN TILE ROOF | | | APPLICATIONS. ALL APPLICABLE DETAILS AND ATTACHMENTS | | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | | DRAWINGS. | | | 2. SUBMITTED MIAMI-DADE COUNTY NOA 22-1221.05 COVERS | | | MULTIPLE PRODUCTS & APPROVED ASSEMBLIES: SYSTEMS E(1) | | | THROUGH E(4). SELECT PRODUCT & SYSTEM TO BE USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-31 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-31 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2023-05-31 14:44:55 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA NO. | | | 18-0409.06 HAS EXPIRED AND IS NO LONGER VALID. PROVIDE | | | A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT | | | SYSTEM TO BE USED. ALL APPLICABLE DETAILS AND | | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | | APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT | | | SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | | SITE-SPECIFIC ENGINEERING. | | | 2. FBC R 301 FAC9N-3 FLORIDA STATE PRODUCT APPROVAL | | | FL5444-R19 IS INCOMPLETE, PROVIDE THE FOLLOWING | | | ADDITIONAL INFORMATION: COVER SHEET | | | (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE | | | VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL | | | INFORMATION ABOUT THE PRODUCT). | | | 3. FBC R 301 FAC9N-3 SUBMITTED STATE OF FLORIDA PRODUCT | | | APPROVAL FL6267-R17 IS NOT APPROVED FOR USE WITH | | | CONCRETE ROOF TILES. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-25 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-19 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-18 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-17 |
Time |
13:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-22 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-12 |
Time |
08:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-08 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-02 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-31 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-18 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|