Plan Review Details - Permit 23050669
| Plan Review Stops For Permit 23050669 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-30 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-30 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2023-06-21 14:57:05 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE GENERATOR EXHAUST IS REQUIRED TO BE AT LEAST 10 | | | FEET FROM ANY OPENINGS INTO A BUILDING. SPECIFY THIS ON | | | THE SURVEY. FBC-R303.5.1 INTAKE OPENINGS. MECHANICAL | | | AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE | | | LOCATED NOT LESS THAN 10 FEET (3048 MM) FROM ANY | | | HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, | | | CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING LOTS | | | AND LOADING DOCKS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-05-17 |
|
|
Cont ID |
|
| Sent By |
jcooley |
Date |
2023-05-17 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
jcooley |
Date |
2023-05-17 |
Time |
17:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-07-06 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-06-26 |
Time |
08:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-05-15 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-21 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-07-06 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-07-06 |
Time |
11:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
gvolcy |
Date |
2023-06-07 |
Time |
17:03 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-06-07 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2023-06-07 17:07:04 | 06.07.2023 - FAILED | | | | | | | | | PROVIDE SIDE SETBACK FOR GENERATOR ON SURVEY. IT CANNOT | | | ENCROACH MORE THAN 4FT INTO REQUIRED SETBACK. | | | | | | WHERE IS THE UNDERGROUND LP TANK DOME PROPOSED? WILL IT | | | BE IN THE MIDDLE OF DRIVEWAY? | | | | | | **** REVIEWD BY **** | | | GAISHA (ANNE) VOLCY | | | PLANNER | | | [email protected] | | | |
|
|
|