Plan Review Details - Permit 23050655
| Plan Review Stops For Permit 23050655 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-27 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2023-07-27 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2023-07-27 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-11 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2023-06-11 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2023-06-11 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2023-06-11 12:19:31 | PLAN REVIEWER: ED ROSEBERRY PX2909 | | | EMAIL: [email protected] | | | PH: 772-359-3502 | | | ***PRIMARY CONTACT IS EMAIL*** | | | | | | 1. PLEASE SUBMIT FBC/NOA FOR ALL REPLACEMENT | | | FENESTRATION, WITH SPECIFIC MODELS, SIZES, AND DESIGN | | | PRESSURE TABLES HIGHLIGHTED. MULLIONS NOT SUBMITTED. | | | FBC 107.2 | | | 2. PLEASE PROVIDE A FLASHING DETAIL, OR ADD A NOTE TO | | | THE PLAN, DEMONSTRATING COMPLIANCE WITH FBC R 703.4 OR | | | FBC B 1405.4. ***NOTE*** THIS IS NOT USUALLY INCLUDED | | | IN FBC/NOA. COMPLIANCE MUST BE SHOWN SEPARATELY. | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-07-06 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-07-06 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2023-07-06 10:14:27 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PLEASE PROVIDE MORE DETAILS ON THE PROPOSED REPLACEMENT | | | WINDOWS. NEED TO KNOW GLASS COLOR (MUST BE CLEAR) | | | WHETHER LOW E COATING WILL BE APPLIED (ONLY PERMISSIBLE | | | SIDE AND REAR ELEVATIONS) FRAME COLOR (SHOULD BE WHITE) | | | AND NUMBERED IMAGES OF ALL WINDOWS TO BE REPLACED. | | | ADDITIONALLY, HR WINDOWS ARE NOT APPROPRIATE FOR | | | HISTORIC DISTRICT AND SHOULD BE REVISED. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-14 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-07-07 |
Time |
08:11 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-15 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-06-11 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2023-06-11 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2023-06-11 |
Time |
12:19 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |