Plan Review Details - Permit 23050638
Plan Review Stops For Permit 23050638
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2023-06-14 Cont ID  
Sent By cpuell Date 2023-06-14 Time 15:25 Rev Time 0.00
Received By cpuell Date 2023-06-14 Time 15:25 Sent To  
Notes
2023-06-14 15:25:59NEW TENANT SPACE HAS BEEN GIVEN THE NEW ADDRESS OF 465
 S ROSEMARY AVE, NEW PAGES WILL NEED TO REFLECT THE NEW
 ADDRESS.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-05-27 Cont ID  
Sent By cpuell Date 2023-05-27 Time 13:18 Rev Time 0.00
Received By cpuell Date 2023-05-27 Time 13:18 Sent To  
Notes
2023-05-27 13:19:34THE APPLICATION AND PLANS ARE NOT LISTING THE CORRECT
 TENANT SPACE ADDRESS PLEASE REACH OUT TO DS_ADDRESSING@
 WPB.ORG OR CALL 561-805-6659 SO THAT THE APPROPRIATE
 ADDRESS CAN BE ASSIGNED TO THE PROJECT.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-07-05 Cont ID  
Sent By rmcphers Date 2023-07-05 Time 13:54 Rev Time 0.00
Received By rmcphers Date 2023-07-05 Time 13:53 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-06-06 Cont ID  
Sent By rmcphers Date 2023-06-06 Time 15:59 Rev Time 0.00
Received By rmcphers Date 2023-06-05 Time 16:38 Sent To  
Notes
2023-06-06 16:00:20PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-07-05 Cont ID  
Sent By rmcphers Date 2023-07-05 Time 13:52 Rev Time 0.00
Received By rmcphers Date 2023-07-05 Time 13:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-06-06 Cont ID  
Sent By rmcphers Date 2023-06-06 Time 16:34 Rev Time 0.00
Received By rmcphers Date 2023-06-05 Time 16:38 Sent To  
Notes
2023-06-06 16:30:34BUILD OUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE A FIRE WALL HOURLY RATING SCHEDULE -
 SHOWING THE TENANT SEPARATION WALL AND THE EXIT PATHWAY
 WALL HOURLY RATING FOR THE ADJACENT TENNANTS - FBC WPB
 107.3.5
  
 2) DRAWING A 401 - PLEASE SHOW THE EXTERIOR WALL
 SHEATHING ATTACHMENTS - FBC 1609
  
 3) DRAWING A 401 - PLEASE SHOW THE EXTERIOR WALL WATER
 RESISTIVE BARRIER - FBC 1404.2 WATER-RESISTIVE BARRIER.
 NOT FEWER THAN ONE LAYER OF NO.15 ASPHALT FELT,
 COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR OTHER
 APPROVED MATERIALS, SHALL BE ATTACHED TO THE STUDS OR
 SHEATHING, WITH FLASHING AS DESCRIBED IN SECTION
 1405.4, IN SUCH A MANNER AS TO PROVIDE A CONTINUOUS
 WATER-RESISTIVE BARRIER BEHIND THE EXTERIOR WALL
 VENEER.
  
 4) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVAL FOR THE EXTERIOR WINDOWS AND DOORS -
 ALL PRODUCT APROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE DESIGNER OF RECORD OR BE LISTED ON THE
 DRAWINGS BY THE PRODUCT APPROVAL NUMBER. FBC 107.3.4
  
 5) ACCESSIBLE RESTROOM = PLEASE SHOW THE DIMENSIONS FOR
 THE TOILET REAR GRAB BAR FROM THE CENTER OF THE TOILET
 NOT 6 INCHES FROM THE WALL - FBC A 604.5.2REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 6) ACCESSIBLE RESTROOM = THE VERTICAL TOILET GRAB BAR
 IS NOT A REQUIREMENT OF THE FBC - PLEASE SHOW THE 12
 INCH CLEARANCE ABOVE THE HORIZONTAL GRAB BAR PER FBC A
 609.3 THE SPACE BETWEEN THE GRAB BAR AND PROJECTING
 OBJECTS ABOVE SHALL BE 12 INCHES (305 MM) MINIMUM.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-07-07 Cont ID  
Sent By jleahy Date 2023-07-07 Time 07:46 Rev Time 0.00
Received By jleahy Date 2023-07-07 Time 07:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-06-05 Cont ID  
Sent By rperdomo Date 2023-06-05 Time 09:15 Rev Time 0.00
Received By rperdomo Date 2023-06-05 Time 07:37 Sent To  
Notes
2023-06-05 09:24:36FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE FEEDER CONDUCTORS INFORMATION FROM
 ELECTRICAL METER "ETR" TO PANEL HA. NEC 215
  
 NOTE: LOW VOLTAGE WIRING REQUIRES A SEPARATE PERMIT
 APPLICATION.
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN P. PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-07-06 Cont ID  
Sent By pleduc Date 2023-07-06 Time   Rev Time 0.00
Received By pleduc Date 2023-07-06 Time 10:26 Sent To  
Notes
2023-07-06 10:26:45FIRE PROVISO:
  
 ANY REMOVAL OR CONSTRUCTION OF WALLS/CEILINGS REQUIRES
 AND EVALUATION OF THE FIRE SPRINKLER AND FIRE ALARM
 SYSTEMS FOR CODE COMPLIANT COVERAGE
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-05-26 Cont ID  
Sent By pleduc Date 2023-05-26 Time   Rev Time 0.00
Received By pleduc Date 2023-05-23 Time 10:13 Sent To  
Notes
2023-05-26 13:40:05FIRE PROVISO:
  
 ANY REMOVAL OR CONSTRUCTION OF WALLS/CEILINGS REQUIRES
 AND EVALUATION OF THE FIRE SPRINKLER AND FIRE ALARM
 SYSTEMS FOR CODE COMPLIANT COVERAGE
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-19 Cont ID  
Sent By lmarchan Date 2023-07-19 Time 13:19 Rev Time 0.00
Received By lmarchan Date 2023-07-03 Time 09:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-20 Cont ID  
Sent By amcgrego Date 2023-06-20 Time 10:51 Rev Time 0.00
Received By lmarchan Date 2023-05-19 Time 12:49 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2023-06-06 Cont ID  
Sent By rmcphers Date 2023-06-06 Time 16:02 Rev Time 0.00
Received By rmcphers Date 2023-06-06 Time 16:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-06-08 Cont ID  
Sent By cmontell Date 2023-06-08 Time 12:46 Rev Time 0.00
Received By cmontell Date 2023-06-08 Time 12:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-07-05 Cont ID  
Sent By ccole Date 2023-07-05 Time 10:32 Rev Time 0.00
Received By ccole Date 2023-07-05 Time 10:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-05-25 Cont ID  
Sent By ccole Date 2023-05-25 Time 17:31 Rev Time 0.00
Received By ccole Date 2023-05-25 Time 15:55 Sent To  
Notes
2023-05-25 17:32:201ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23050638
 5/25/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P300 DETAIL 8: THE EXPANSION TANKS HALL BE
 LOCATED AT A POINT ON THE COLD WATER FEED THAT IS
 DOWNSTREAM OF THE CHECK VALVE- SEC. 607.3 FBC P.
  
 2) P200, P300, P400: THE THERMOSTAT CONTROL ON THE
 WATER HEATER CANNOT BE THE LIMITING DEVICE FOR HOT
 WATER DELIVERY. PLEASE PROVIDE A DETAIL FOR A LIMITING
 DEVICE FOR THE PURPOSE OF HOT WATER DELIVERY. THIS
 WOULD BE IN ADDITION TO THE REQUIREMENTS FOR TEMPERED
 WATER FOR PUBLIC HAND-WASHING 607.1.2/419.5 FBC P.
 TYPICALLY A MASTER THERMOSTATIC MIXING VALVE COMPLYING
 WITH ASSE 1017 WOULD MEET COMPLIANCE. PLEASE REVISE THE
 PLAN ACCORDINGLY AND SHOW THE REQUIRED PIPING
 CONNECTIONS PER SEC. 607.2.2.
  
 3) A625 DETAIL C: THE CENTERLINE OF THE TOILET PAPER
 DISPENSER SHALL BE LOCATED 7 INCHES MINIMUM AND
 9-INCHES MAXIMUM FROM THE FRONTS OF THE WATER CLOSETS-
 SEC. AND FIGURE 604.7. THE DETAIL DOES NOT SHOW THE
 8-INCH MEASUREMENT TO THE CENTER OF THE DISPENSER-
 PLEASE CORRECT.
  
 4) A113: SHOW THE CLEAR FLOOR SPACE DIAGRAM AND THE
 KNEE AND TOE CLEARANCES FOR THE WHEELCHAIR ACCESSIBLE
 DRINKING FOUNTAIN- SEC. 602.2 FBC ACC.
  
 A) PROVIDE AN ELEVATION DETAIL SHOWING THE HI AND LO
 SPOUT HEIGHTS- SECS. 602.4 & 602.7.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-07-05 Cont ID  
Sent By rmcphers Date 2023-07-05 Time 13:53 Rev Time 0.00
Received By rmcphers Date 2023-07-05 Time 13:53 Sent To  
Notes
2023-07-05 10:33:42PLUMBING PLAN SIGS PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-06-06 Cont ID  
Sent By rmcphers Date 2023-06-06 Time 16:49 Rev Time 0.00
Received By rmcphers Date 2023-06-06 Time 16:49 Sent To  
Notes
2023-05-25 17:33:03PLUMBING SIGNATURES PASSED.

Review Stop Z ZONING
Rev No 2 Status P Date 2023-07-19 Cont ID  
Sent By eschneid Date 2023-07-19 Time 10:46 Rev Time 0.75
Received By eschneid Date 2023-07-19 Time 09:03 Sent To  
Notes
2023-07-19 10:46:03SIGNS REQUIRE A SEPARATE PERMIT.

Review Stop Z ZONING
Rev No 1 Status F Date 2023-06-20 Cont ID  
Sent By eschneid Date 2023-06-20 Time 10:45 Rev Time 1.00
Received By eschneid Date 2023-06-20 Time 09:49 Sent To  
Notes
2023-06-20 10:45:58FAILED
  
 1) THE CITYPLACE RETAIL MANAGEMENT APPROVAL STAMP IS
 REQUIRED ON THE PLANS. ALTERNATIVELY, YOU MAY PROVIDE A
 LETTER FROM CITYPLACE RETAIL MANAGEMENT WHICH APPROVES
 THE SPECIFIC PLANS SUBMITTED AS PART OF THE PERMIT.
  
 2) THE 477 SOUTH ROSEMARY BUILDING IS REQUIRED TO HAVE
 A MINIMUM PERCENTAGE OF TRANSPARENCY BETWEEN GRADE AND
 10 FEET. THE APPROVED LANDLORD SHELL PERMIT FOR THIS
 BAY SHOWS STOREFRONT ENTRY HAVING 142 SQUARE FEET OF
 GLAZING AND THE STOREFRONT WINDOW HAVING 97 SQUARE FEET
 OF GLAZING. THE PROPOSED ENTRY AND WINDOW DO NOT MATCH
 WHAT IS SHOWN ON THE LANDLORD APPROVED PLANS, SO YOU
 MUST PROVIDE THE DIMENSIONS AND SQUARE FOOTAGE OF THE
 PROPOSED ENTRY AND WINDOW ON SHEET A300 SHOPFRONT
 ELEVATIONS. THE PROPOSED GLAZING MAY NOT BE LESS THAN
 WHAT IS APPROVED ON THE LANDLORD PLANS AND MUST BE ONLY
 THE GLAZING BETWEEN GRADE AND 10 FEET.
  
 3) THE PLANS STATE THAT SIGNAGE WILL BE UNDER SEPARATE
 PERMIT. THE GRAPHICS APPLIED TO THE WINDOW MUST BE
 INCLUDED AS PART OF THE SIGN PERMIT AND ARE NOT
 APPROVED AS PART OF THIS PERMIT. PLEASE NOTE THAT SHEET
 A310 HAS BEEN DELETED FROM THIS PERMIT SUBMITTAL.
  
 4) SHEET E300 SHOWS A JUNCTION BOX AT THE PROPOSED
 EXTERIOR ARCADE SIGN. THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA REQUIRE ALL CONDUIT, RACEWAYS, WIRING, BALLAST
 BOXES, TRANSFORMERS, JUNCTION BOXES, BELL BOXES, POWER
 SUPPLY AND OTHER EQUIPMENT NECESSARY FOR SIGN
 CONNECTION SHALL BE CONCEALED AND NOT VISIBLE TO THE
 PUBLIC. IF THE JUNCTION BOX, CONDUIT, ETC. FOR THE SIGN
 ARE PROPOSED TO BE INSTALLED WITH THIS BUILD OUT
 PERMIT, DETAILED DRAWINGS VERIFYING THAT ALL THE
 ELECTRICAL COMPONENTS FOR THE SIGN, INCLUDING THE POWER
 SUPPLY AND THE COMPONENTS TO GET THE POWER TO THE SIGN
 ARE CONCEALED IN THE CEILING OR WITHIN THE STORE MUST
 BE PROVIDED AT THIS TIME.
  
 CONTACT ERIC SCHNEIDER @ 561-822-1446
 [email protected]
  