| Plan Review Stops For Permit 23050638 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-06-14 |
Time |
15:25 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-06-14 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2023-06-14 15:25:59 | NEW TENANT SPACE HAS BEEN GIVEN THE NEW ADDRESS OF 465 | | | S ROSEMARY AVE, NEW PAGES WILL NEED TO REFLECT THE NEW | | | ADDRESS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-27 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-05-27 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-05-27 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2023-05-27 13:19:34 | THE APPLICATION AND PLANS ARE NOT LISTING THE CORRECT | | | TENANT SPACE ADDRESS PLEASE REACH OUT TO DS_ADDRESSING@ | | | WPB.ORG OR CALL 561-805-6659 SO THAT THE APPROPRIATE | | | ADDRESS CAN BE ASSIGNED TO THE PROJECT. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-05 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-05 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-06 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-05 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2023-06-06 16:00:20 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-05 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-05 |
Time |
13:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-06 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-05 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2023-06-06 16:30:34 | BUILD OUT | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE A FIRE WALL HOURLY RATING SCHEDULE - | | | SHOWING THE TENANT SEPARATION WALL AND THE EXIT PATHWAY | | | WALL HOURLY RATING FOR THE ADJACENT TENNANTS - FBC WPB | | | 107.3.5 | | | | | | 2) DRAWING A 401 - PLEASE SHOW THE EXTERIOR WALL | | | SHEATHING ATTACHMENTS - FBC 1609 | | | | | | 3) DRAWING A 401 - PLEASE SHOW THE EXTERIOR WALL WATER | | | RESISTIVE BARRIER - FBC 1404.2 WATER-RESISTIVE BARRIER. | | | NOT FEWER THAN ONE LAYER OF NO.15 ASPHALT FELT, | | | COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR OTHER | | | APPROVED MATERIALS, SHALL BE ATTACHED TO THE STUDS OR | | | SHEATHING, WITH FLASHING AS DESCRIBED IN SECTION | | | 1405.4, IN SUCH A MANNER AS TO PROVIDE A CONTINUOUS | | | WATER-RESISTIVE BARRIER BEHIND THE EXTERIOR WALL | | | VENEER. | | | | | | 4) PLEASE PROVIDE A COMPLETE (FRONT PAGES AND THE | | | INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE | | | PRODUCT APPROVAL FOR THE EXTERIOR WINDOWS AND DOORS - | | | ALL PRODUCT APROVALS NEED TO BE REVIEWED AND MARKED | | | APPROVED BY THE DESIGNER OF RECORD OR BE LISTED ON THE | | | DRAWINGS BY THE PRODUCT APPROVAL NUMBER. FBC 107.3.4 | | | | | | 5) ACCESSIBLE RESTROOM = PLEASE SHOW THE DIMENSIONS FOR | | | THE TOILET REAR GRAB BAR FROM THE CENTER OF THE TOILET | | | NOT 6 INCHES FROM THE WALL - FBC A 604.5.2REAR WALL. | | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG | | | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER | | | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 | | | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. | | | | | | 6) ACCESSIBLE RESTROOM = THE VERTICAL TOILET GRAB BAR | | | IS NOT A REQUIREMENT OF THE FBC - PLEASE SHOW THE 12 | | | INCH CLEARANCE ABOVE THE HORIZONTAL GRAB BAR PER FBC A | | | 609.3 THE SPACE BETWEEN THE GRAB BAR AND PROJECTING | | | OBJECTS ABOVE SHALL BE 12 INCHES (305 MM) MINIMUM. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-07 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-07 |
Time |
07:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-06-05 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-06-05 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-06-05 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2023-06-05 09:24:36 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE FEEDER CONDUCTORS INFORMATION FROM | | | ELECTRICAL METER "ETR" TO PANEL HA. NEC 215 | | | | | | NOTE: LOW VOLTAGE WIRING REQUIRES A SEPARATE PERMIT | | | APPLICATION. | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN P. PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER/ INSPECTOR | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-07-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-06 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2023-07-06 10:26:45 | FIRE PROVISO: | | | | | | ANY REMOVAL OR CONSTRUCTION OF WALLS/CEILINGS REQUIRES | | | AND EVALUATION OF THE FIRE SPRINKLER AND FIRE ALARM | | | SYSTEMS FOR CODE COMPLIANT COVERAGE | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-23 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2023-05-26 13:40:05 | FIRE PROVISO: | | | | | | ANY REMOVAL OR CONSTRUCTION OF WALLS/CEILINGS REQUIRES | | | AND EVALUATION OF THE FIRE SPRINKLER AND FIRE ALARM | | | SYSTEMS FOR CODE COMPLIANT COVERAGE | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-07-19 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-07-03 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
amcgrego |
Date |
2023-06-20 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-05-19 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-06 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-06 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-08 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-08 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-05 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-05 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-25 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-25 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2023-05-25 17:32:20 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 23050638 | | | 5/25/2023 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P300 DETAIL 8: THE EXPANSION TANKS HALL BE | | | LOCATED AT A POINT ON THE COLD WATER FEED THAT IS | | | DOWNSTREAM OF THE CHECK VALVE- SEC. 607.3 FBC P. | | | | | | 2) P200, P300, P400: THE THERMOSTAT CONTROL ON THE | | | WATER HEATER CANNOT BE THE LIMITING DEVICE FOR HOT | | | WATER DELIVERY. PLEASE PROVIDE A DETAIL FOR A LIMITING | | | DEVICE FOR THE PURPOSE OF HOT WATER DELIVERY. THIS | | | WOULD BE IN ADDITION TO THE REQUIREMENTS FOR TEMPERED | | | WATER FOR PUBLIC HAND-WASHING 607.1.2/419.5 FBC P. | | | TYPICALLY A MASTER THERMOSTATIC MIXING VALVE COMPLYING | | | WITH ASSE 1017 WOULD MEET COMPLIANCE. PLEASE REVISE THE | | | PLAN ACCORDINGLY AND SHOW THE REQUIRED PIPING | | | CONNECTIONS PER SEC. 607.2.2. | | | | | | 3) A625 DETAIL C: THE CENTERLINE OF THE TOILET PAPER | | | DISPENSER SHALL BE LOCATED 7 INCHES MINIMUM AND | | | 9-INCHES MAXIMUM FROM THE FRONTS OF THE WATER CLOSETS- | | | SEC. AND FIGURE 604.7. THE DETAIL DOES NOT SHOW THE | | | 8-INCH MEASUREMENT TO THE CENTER OF THE DISPENSER- | | | PLEASE CORRECT. | | | | | | 4) A113: SHOW THE CLEAR FLOOR SPACE DIAGRAM AND THE | | | KNEE AND TOE CLEARANCES FOR THE WHEELCHAIR ACCESSIBLE | | | DRINKING FOUNTAIN- SEC. 602.2 FBC ACC. | | | | | | A) PROVIDE AN ELEVATION DETAIL SHOWING THE HI AND LO | | | SPOUT HEIGHTS- SECS. 602.4 & 602.7. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-05 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-05 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-05 |
Time |
13:53 |
Sent To |
|
|
| Notes |
| 2023-07-05 10:33:42 | PLUMBING PLAN SIGS PASSED. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-06 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-06 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2023-05-25 17:33:03 | PLUMBING SIGNATURES PASSED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-19 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2023-07-19 |
Time |
10:46 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2023-07-19 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2023-07-19 10:46:03 | SIGNS REQUIRE A SEPARATE PERMIT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2023-06-20 |
Time |
10:45 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2023-06-20 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2023-06-20 10:45:58 | FAILED | | | | | | 1) THE CITYPLACE RETAIL MANAGEMENT APPROVAL STAMP IS | | | REQUIRED ON THE PLANS. ALTERNATIVELY, YOU MAY PROVIDE A | | | LETTER FROM CITYPLACE RETAIL MANAGEMENT WHICH APPROVES | | | THE SPECIFIC PLANS SUBMITTED AS PART OF THE PERMIT. | | | | | | 2) THE 477 SOUTH ROSEMARY BUILDING IS REQUIRED TO HAVE | | | A MINIMUM PERCENTAGE OF TRANSPARENCY BETWEEN GRADE AND | | | 10 FEET. THE APPROVED LANDLORD SHELL PERMIT FOR THIS | | | BAY SHOWS STOREFRONT ENTRY HAVING 142 SQUARE FEET OF | | | GLAZING AND THE STOREFRONT WINDOW HAVING 97 SQUARE FEET | | | OF GLAZING. THE PROPOSED ENTRY AND WINDOW DO NOT MATCH | | | WHAT IS SHOWN ON THE LANDLORD APPROVED PLANS, SO YOU | | | MUST PROVIDE THE DIMENSIONS AND SQUARE FOOTAGE OF THE | | | PROPOSED ENTRY AND WINDOW ON SHEET A300 SHOPFRONT | | | ELEVATIONS. THE PROPOSED GLAZING MAY NOT BE LESS THAN | | | WHAT IS APPROVED ON THE LANDLORD PLANS AND MUST BE ONLY | | | THE GLAZING BETWEEN GRADE AND 10 FEET. | | | | | | 3) THE PLANS STATE THAT SIGNAGE WILL BE UNDER SEPARATE | | | PERMIT. THE GRAPHICS APPLIED TO THE WINDOW MUST BE | | | INCLUDED AS PART OF THE SIGN PERMIT AND ARE NOT | | | APPROVED AS PART OF THIS PERMIT. PLEASE NOTE THAT SHEET | | | A310 HAS BEEN DELETED FROM THIS PERMIT SUBMITTAL. | | | | | | 4) SHEET E300 SHOWS A JUNCTION BOX AT THE PROPOSED | | | EXTERIOR ARCADE SIGN. THE ROSEMARY SQUARE TENANT SIGN | | | CRITERIA REQUIRE ALL CONDUIT, RACEWAYS, WIRING, BALLAST | | | BOXES, TRANSFORMERS, JUNCTION BOXES, BELL BOXES, POWER | | | SUPPLY AND OTHER EQUIPMENT NECESSARY FOR SIGN | | | CONNECTION SHALL BE CONCEALED AND NOT VISIBLE TO THE | | | PUBLIC. IF THE JUNCTION BOX, CONDUIT, ETC. FOR THE SIGN | | | ARE PROPOSED TO BE INSTALLED WITH THIS BUILD OUT | | | PERMIT, DETAILED DRAWINGS VERIFYING THAT ALL THE | | | ELECTRICAL COMPONENTS FOR THE SIGN, INCLUDING THE POWER | | | SUPPLY AND THE COMPONENTS TO GET THE POWER TO THE SIGN | | | ARE CONCEALED IN THE CEILING OR WITHIN THE STORE MUST | | | BE PROVIDED AT THIS TIME. | | | | | | CONTACT ERIC SCHNEIDER @ 561-822-1446 | | | [email protected] | | | |
|
|