| Plan Review Stops For Permit 23050553 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-06-01 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-06-01 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2023-06-01 11:29:02 | PARCEL HAS BEEN APPROVED AND READDRESSED TO 6625 S | | | FLAGLER DR |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-05-30 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-05-30 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2023-05-30 16:14:13 | PARCEL NEEDS TO BE READDRESSED SO THAT THE ENTRANCES ON | | | THE GROUND FLOOR FALLS IN LINE WITH THE CITY'S ROAD | | | CENTER LINES. BASED ON THAT IINFORMATION, THE FOLLOWING | | | ADDRESSES ARE AVAILABLE; 6625 6627 OR 6629 S FLAGLER | | | DR, PLEASE PRESENT THESE ADDRESSES TO THE OWNER SO THAT | | | WE CAN READDRESS THE PARCEL AND ACTIVE THE NEW ADDRESS. | | | PLEASE HAVE THEM RESPOND TO [email protected] OR | | | CALL 561-805-6659 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-27 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-06-22 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2023-06-27 14:15:49 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM US-21-11935 | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: THE SURVEY SUBMITTED FOR REVIEW STATES THE | | | PROPERTY IS LOCATED ON FLOOD ZONE X. PALM BEACH COUNTY | | | GIS SHOWS THE PROPERTY IS LOCATED IN A SPECIAL FLOOD | | | HAZARD AREA (SFHA) WITH TWO FLOOD ZONES, X-500 AND AE7 | | | WITH A BASE FLOOD ELEVATION (BFE) OF 7.0' NAVD. | | | | | | 1.PROVIDE A COPY OF THE MOST RECENT BOUNDARY LINE | | | SURVEY. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | | | | 2. PLAN PAGE A-002 SHOWS 4 FLOOD VENTS INSTALLED ON ONE | | | WALL. FLOOD VENTS SHALL BE INSTALLED ON ADJACENT WALLS | | | PER FEMA TECH. BULLITEN #1. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 3. IDENTIFY TYPE OF SMART VENTS TO BE INSTALLED ON | | | FLOOR PLAN A-002. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 4. IDENTIFY COVERAGE EACH VENT PROVIDES ON FLOOR PLAN | | | A-002. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | 5.PROVIDE ROOF DRAINAGE PLAN | | | R903.4ROOF DRAINAGE. | | | UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF | | | DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE | | | ROOF. WHERE REQUIRED FOR ROOF DRAINAGE, SCUPPERS SHALL | | | BE PLACED LEVEL WITH THE ROOF SURFACE IN A WALL OR | | | PARAPET. THE SCUPPER SHALL BE LOCATED AS DETERMINED BY | | | THE ROOF SLOPE AND CONTRIBUTING ROOF AREA. | | | R903.4.1OVERFLOW DRAINS AND SCUPPERS. | | | WHEN OTHER MEANS OF DRAINAGE OF OVERFLOW WATER IS NOT | | | PROVIDED, OVERFLOW SCUPPERS SHALL BE PLACED IN WALLS OR | | | PARAPETS NOT LESS THAN 2 INCHES (51 MM) NOR MORE THAN 4 | | | INCHES (102 MM) ABOVE THE FINISHED ROOF COVERING AND | | | SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED | | | VERTICAL LEADERS OR DOWN-SPOUTS OR WALL AND PARAPET | | | SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. | | | OVERFLOW DRAINS SHALL DISCHARGE TO AN APPROVED LOCATION | | | AND SHALL NOT BE CONNECTED TO ROOF DRAIN LINES. | | | | | | 6. SUBMIT A CORRECTED CONSTRUCTION DRAWING ELEVATION | | | CERTIFICATE FOR REVIEW. | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-06-06 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-06-06 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2023-06-06 14:58:52 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: APPROVED, SEE COMMENTS BELOW | | | | | | 1. THE FOLLOWING ACTIVITIES REQUIRE A SEPARATE PERMIT | | | APPLICATION: | | | A. LOW VOLTAGE WIRING | | | B. SWIMMING POOL | | | C. GENERATOR SYSTEM | | | | | | END OF COMMENTS | | | | | | RUBEN P. PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER/ INSPECTOR | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
parking |
Date |
2023-06-01 |
Time |
19:37 |
Rev Time |
0.00 |
| Received By |
lquinone |
Date |
2023-06-01 |
Time |
19:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-31 |
Time |
06:21 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-31 |
Time |
06:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-27 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-23 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-13 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-13 |
Time |
11:21 |
Sent To |
|
|
| Notes |
| 2023-06-13 11:22:45 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23050553 | | | | | | REVIEWED: 6.13.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-06-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-06-16 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-06-16 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2023-06-16 11:02:47 | PASS PROVISO | | | REFER TO SECTION M1602 #4 RETURN AIR CAN'T BE TAKEN | | | FROM A CLOSET OR BATHROOM 2020 FBC (R) | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
F |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-27 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-06-22 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2023-06-27 15:31:49 | 1ST NFIP REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM US-21-11935 | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | CITY ORDINANCE NO. 4658-16 AND NO. 4729-17 | | | FEMA DESK REFERENCE P 758 | | | FBC R322 FLOOD-RESISTANT CONSTRUCTION | | | | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD | | | AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS SITE | | | IS AE 7 WITH A BASE FLOOD ELEVATION (BFE) OF 7???0??? | | | NAVD. | | | THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO. | | | 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD. | | | THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE | | | 9???0??? NAVD. | | | | | | CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17 | | | SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT | | | CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE | | | II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL | | | AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH | | | SHALL READ AS FOLLOWS: | | | SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING | | | CODE, RESIDENTIAL. | | | R322.2.1 ELEVATION REQUIREMENTS. | | | 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT | | | DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST | | | FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION | | | PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER | | | IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17). | | | | | | 2. LINE A1 - THE CORRECT ADDRESS FOR THE PROPERTY IS | | | 6625 S FLAGLER DR. | | | 3. LINE A9D) STATES FLOOD OPENINGS ARE NON-ENGINEERED. | | | PLAN PAGE A-002 SHOWS (4) ENGINEERED SMART VENTS | | | INSTALLED. PLEASE CLARIFY? | | | 4. LINE A8B) & C) SHALL BE N/A PER EC INSTRUCTIONS. | | | 5. LINE A9 - YOU MAY ENTER A VALUE OF 800 IN THIS | | | SECTION PER FEMA TECHNICAL BULLITEN #1 SECTION 9.PG. 39 | | | 6. LINE B8 SHOULD BE X-500 AND AE7. | | | 7. LINE B9 SHOULD BE 7.0' NAVD. | | | 8. LINE C2B) - TOP OF NEXT HIGHEST FLOOR SHOULD BE | | | 22.33' PER PLAN PAGE A-005. | | | 9. LINE C2E) SHALL BE A MINIMUM OF 9.0' NAVD. | | | 10. SECTION D COMMENTS - | | | 10A) REMOVE - VACANT LOT. | | | 10B) REMOVE - CROWN OF ROAD. | | | 10C) REMOVE - THIS IS A PROPOSED EC. | | | 10D) ADD - MACHINERY SERVICING THE BUILDING IN SECTION | | | C2E) ARE A/C CONDENSING UNITS AT WEST ELEVATION OF | | | BUILDING. | | | 10E) ADD - SMART VENT MODEL # _________ | | | 10F) ADD - COVERAGE PER VENT IS __________ | | | | | | NOTICE: PROVIDE THE FOLLOWING (3) ELEVATION | | | CERTIFICATES AS REQUIRED. | | | A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS | | | REQUIRED AT TIME OF PERMIT APPLICATION. | | | | | | A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AT PLACEMENT OF 1ST FLOOR. | | | | | | A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS | | | REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL | | | PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-31 |
Time |
06:02 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-31 |
Time |
05:53 |
Sent To |
|
|
| Notes |
| 2023-05-31 06:16:38 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FRC P3101.2.1 - THE WATER CLOSET IN THE POWDER | | | BATH NEXT TO THE PANTRY IS NOT VENTED TO CODE. THE | | | LAUNDRY TUB AND/OR WASHING MACHINE CANNOT ACT AS THE | | | WET VENT AS THEY ARE NOT BATHROOM GROUP FIXTURES. ONLY | | | BATHROOM GROUP FIXTURES CAN BE INCLUDED IN WET VENTS. | | | | | | 2. CITY ORD. SEC. 90 - 126. - ON PAGE P1.1 - BETWEEN | | | LIVING ROOM AND FAMILY ROOM NEAR FOYER, THERE IS A KEY | | | NOTE "8" THAT INDICATES THERE IS A CONDENSATE THAT | | | DISCHARGES INTO THE SANITARY. PLEASE FIX THE KEY NOTE. | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-06-27 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-06-22 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2023-06-27 10:26:57 | PLAN REVIEW ROOFING | | | | | | 1ST ROOFING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. IDENTIFY THE SYSTEM TO BE INSTALLED ON PRODUCT | | | APPROVAL FL16709-R10. | | | 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS | | | SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH | | | 107.2.5. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-13 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-13 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
lgelman |
Date |
2023-06-22 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-06-22 |
Time |
17:24 |
Sent To |
|
|
| Notes |
| 2023-06-22 17:34:08 | SEPARATE PERMIT REQUIRED FOR: | | | FENCE/WALL, AWNINGS, SIGNS, PARKING LOT, GENERATOR, | | | MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE, | | | IRRIGATION, LANDSCAPE, OTHER. WALLS, POOL, POOL | | | EQUIPMENT AND MECHANICAL EQUIPMENT WILL NOT BE REVIEWED | | | ON THIS PERMIT. PLEASE APPLY FOR PERMITS FOR EACH | | | STRUCTURE. | | | | | | FENCES AND WALLS CANNOT EXCEED 4 FEET IN HEIGHT WITHIN | | | THE FIRST 25 FEET FRONT YARD SETBACK. REVISE SHEET | | | 017L1.0-SITE PLAN FOR MAXIMUM HEIGHT OF WALLS IN THE | | | FRONT YARD. | | | | | | ***** REVIEWED BY ***** | | | LIDNSEY GELMAN | | | 561-822-1275 | | | [email protected] |
|
|