| Plan Review Stops For Permit 23050539 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-13 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-13 |
Time |
09:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-26 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-26 |
Time |
13:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-18 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-18 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2023-07-18 11:52:29 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. 2017 NEC 230.42 PLAN SHOWES 175 AMP LOAD ON 150 AMP | | | PANEL. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-07 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-07 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2023-07-07 09:20:56 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. 2017 NEC 230.42 PLAN SHOWES 175 AMP LOAD ON 150 AMP | | | PANEL. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-06-01 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-06-01 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2023-06-01 07:49:26 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | | 7TH ED, CHAPTER 1. | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | | 2. PLEASE REVIEW BREAKER,WIRE AND CONDUIT SIZE TO HEAT | | | PUMP #12 ON 60A BREAKER. | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | SINCERELY, | | | | | | PHIL PETTY | | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | | | 561-805-6742 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-26 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-26 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-18 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-12 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-07 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-06 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-29 |
|
|
Cont ID |
|
| Sent By |
lngelman |
Date |
2023-06-29 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-05-31 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-13 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-13 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-07 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-07 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2023-07-07 07:56:03 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 23050539 | | | 7/7/23 | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE REVISED POOL PLAN SHEET 2 DOES NOT HAVE A | | | VERIFIABLE DIGITAL SIGNATURE AND SEAL BY THE ENGINEER | | | OF RECORD- FL. STATUTE 471.025 AND SEC. 61G15-23.005 | | | FAC. THERE APPEARS TO HAVE BEEN AN ERROR IN THE SIGNING | | | AND TRANSMITTAL PROCESSING OF THE SHEET WHICH | | | TERMINATES THE PLAN REVIEWER'S ACCESS TO CHECK 3RD | | | PARTY CERTIFICATION OF THE SIGNATURE AND SEAL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-01 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-01 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-18 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2023-07-18 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2023-07-18 |
Time |
11:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-07-07 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-07-07 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2023-07-07 07:57:30 | ELECTRONIC SIGNATURE REVIEW | | | PERMIT- 23050539 | | | 7/7/23 | | | | | | CODES IN EFFECT: | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE REVISED POOL PLAN SHEET 2 DOES NOT HAVE A | | | VERIFIABLE DIGITAL SIGNATURE AND SEAL BY THE ENGINEER | | | OF RECORD- FL. STATUTE 471.025 AND SEC. 61G15-23.005 | | | FAC. THERE APPEARS TO HAVE BEEN AN ERROR IN THE SIGNING | | | AND TRANSMITTAL PROCESSING OF THE SHEET WHICH | | | TERMINATES THE PLAN REVIEWER'S ACCESS TO CHECK 3RD | | | PARTY CERTIFICATION OF THE SIGNATURE AND SEAL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-01 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-01 |
Time |
07:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-06-29 |
|
|
Cont ID |
|
| Sent By |
lgelman |
Date |
2023-06-29 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-06-29 |
Time |
10:17 |
Sent To |
|
|
| Notes |
|
|