Plan Review Details - Permit 23050535
| Plan Review Stops For Permit 23050535 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-03 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-03 |
Time |
08:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-13 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-13 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2023-06-13 13:01:21 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL2533-R29 SYSTEM NO. W-65 DO NOT MEET THE | | | MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -142.8 | | | FOR EXPOSURE CATEGORY D AREAS AS PER PREVIOUS SUBMITTED | | | SIGNED AND SEALED DESIGN PRESSURE CALCULATIONS. PROVIDE | | | SYSTEM THAT MEETS OR EXCEEDS ALL DESIGN PRESSURE | | | REQUIREMENTS FOR EXPOSURE CATEGORY D/PROVIDE SIGNED AND | | | SEALED ENGINEERED NAILING CALCULATIONS WITH AN APPROVED | | | SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-30 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-30 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2023-05-30 11:05:07 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL2533-R29 SYSTEM NO. W-114 DO NOT MEET THE | | | MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -142.8 | | | FOR EXPOSURE CATEGORY D AREAS AS PER PREVIOUS SUBMITTED | | | SIGNED AND SEALED DESIGN PRESSURE CALCULATIONS. PROVIDE | | | SYSTEM THAT MEETS OR EXCEEDS ALL DESIGN PRESSURE | | | REQUIREMENTS FOR EXPOSURE CATEGORY D/PROVIDE SIGNED AND | | | SEALED ENGINEERED NAILING CALCULATIONS WITH AN APPROVED | | | SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-03 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-26 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-13 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-05 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-30 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-15 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-03 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-03 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
|