Plan Review Details - Permit 23050327
| Plan Review Stops For Permit 23050327 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-10 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-10 |
Time |
11:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-06-20 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-06-20 |
Time |
17:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-07-10 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-07-10 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-05-30 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-05-30 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-05-25 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2023-05-30 14:55:11 | ELECTRIC REVIEW FAILED | | | | | | 1) PLEASE PROVIDE PANEL SCHEDULES AND LOAD CALCULATIONS | | | FOR EACH MAIN SERVICE PANEL DETAILING AMPACITY OF | | | FEEDERS, 130 AMP, #1 CU CONDUCTORS, HAVE AN AMPACITY OF | | | NOT LESS THAN THE MAXIMUM LOAD SERVED IN ACCORDANCE | | | WITH NEC 230.42(A). | | | | | | PLEASE NOTE THAT NEC 310.15 (B)(7)(2) IS NOT APPLICABLE | | | TO THIS DESIGN AS THE SERVICE ENTRANCE CONDUCTORS DO | | | NOT SERVE THE ENTIRE LOAD ASSOCIATED WITH THE DWELLING. | | | | | | HOWEVER, IF THE LOAD CALCULATED FOR EACH SET OF SERVICE | | | ENTRANCE CONDUCTORS IS LESS THEN THE DESIGNED AMPACITY | | | OF THE #1 CU CONDUCTORS, 130 AMPS, THEN THE NEXT HIGHER | | | STANDARD SIZED OVERCURRENT PROTECTION OF 150 AMPS, MAY | | | BE USED IN ACCORDANCE WITH NEC 240.4(B) | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-07-11 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-06-29 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-06-20 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-05-11 |
Time |
11:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-07-10 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-07-10 |
Time |
09:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-06-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-06-20 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-06-20 |
Time |
17:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-07-11 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-07-11 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-18 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-05-18 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-05-18 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2023-05-18 16:10:45 | FAILED FOR THE FOLLOWING REASON(S): | | | | | | 1. PLEASE SHOW THE HEIGHT FROM THE ROOF TO THE TOP OF | | | THE SOLAR PANALS: | | | | | | ON SLOPED ROOFS, THE HIGHEST POINT OF THE SOLAR | | | COLLECTORS SHALL NOT EXCEED THE HIGHEST ROOFTOP PEAK | | | AND MUST BE INSTALLED PARALLEL TO THE ROOF SURFACES TO | | | WHICH THEY ARE ATTACHED PROVIDED SUCH LOCATION DOES NOT | | | IMPAIR THE EFFECTIVE OPERATION OF THE SOLAR COLLECTORS. | | | SOLAR COLLECTORS MAY BE MOUNTED UP TO ONE FOOT ABOVE | | | ROOF SURFACES TO WHICH THEY ARE ATTACHED. | | | | | | | | | **** REVIEWD BY **** | | | VALENTINA BROGLIA | | | PLANNER | | | [email protected] | | | | | | |
|
|
|