Plan Review Details - Permit 23050019
Plan Review Stops For Permit 23050019
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2023-06-30 Cont ID  
Sent By cpuell Date 2023-06-30 Time 12:23 Rev Time 0.00
Received By cpuell Date 2023-06-30 Time 12:23 Sent To  
Notes
2023-06-30 12:23:46APPLICANT STATED THAT THE AREA OF WORK IS FOR 901
 VILLAGE BLVD 700 UPDATED PERMIT

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-05-30 Cont ID  
Sent By cpuell Date 2023-05-30 Time 16:35 Rev Time 0.00
Received By cpuell Date 2023-05-30 Time 16:35 Sent To  
Notes
2023-05-30 16:35:52SUITE B IS NOT A RECOGNIZED SUITE NUMBER, PLEASE
 PROVIDE A FLOOR PLAN SHOWING EVERY SUITE ON THAT FLOOR.
 PLEASE EMAIL TO [email protected] FOR FURTHER
 QUESTIONS YOU CAN ALSO CALL 561-805-6659

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By jwitmer Date 2023-07-18 Time 08:09 Rev Time 0.00
Received By jwitmer Date 2023-07-18 Time 08:05 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-06-28 Cont ID  
Sent By jwitmer Date 2023-06-28 Time 11:05 Rev Time 0.00
Received By jwitmer Date 2023-06-28 Time 11:05 Sent To  
Notes
2023-06-28 11:05:40COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING
 THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS
 PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM
 BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION
 WILL BE GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By jwitmer Date 2023-07-18 Time 08:10 Rev Time 0.00
Received By jwitmer Date 2023-07-18 Time 08:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-06-28 Cont ID  
Sent By jwitmer Date 2023-06-28 Time 11:25 Rev Time 0.00
Received By jwitmer Date 2023-06-28 Time 11:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-06-21 Cont ID  
Sent By mpeterso Date 2023-06-21 Time 12:51 Rev Time 0.00
Received By mpeterso Date 2023-06-21 Time 12:47 Sent To  
Notes
2023-06-21 14:12:43ELECTRIC REVIEW FAILED
  
 1) PLEASE DETAIL ALL TREATMENT ROOM RECEPTACLES TO
 COMPLY WITH THE FOLLOWING:
 517.13 GROUNDING OF RECEPTACLES AND FIXED ELECTRICAL
 EQUIPMENT IN PATIENT CARE SPACES
 (A) WIRING METHODS. ALL BRANCH CIRCUITS SERVING PATIENT
 CARE SPACES SHALL BE PROVIDED WITH AN EFFECTIVE
 GROUND-FAULT CURRENT PATH BY INSTALLATION IN A METAL
 RACEWAY SYSTEM OR A CABLE HAVING A METALLIC ARMOR OR
 SHEATH ASSEMBLY
  
 2) PLEASE DETAIL ANY RECEPTACLES WITHIN 6 FEET OF ANY
 SINK AS BEING GFI PROTECTED IN ACCORDANCE WITH NEC
 210.8 (B)(5). THIS SHOULD INCLUDE RECEPTACLES WITHIN 6
 FEET OF TREATMENT ROOM SINKS
  
 3) PLEASE DETAIL ANY APPLICABLE RECEPTACLES ARE TAMPER
 RESISTANT IN ACCORDANCE WITH NEC 406.12
  
 4) PLEASE PROVIDE A NOTE STATING ALL LOW VOLTAGE WIRING
 INCLUDING BUT NOT LIMITED TO VOICE, DATA, FIRE ALARM,
 ACCESS CONTROL, SECURITY AND SIGNS REQUIRE A SEPARATE
 PERMIT
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2023-12-12 Cont ID  
Sent By jleahy Date 2023-12-12 Time 09:43 Rev Time 0.00
Received By jleahy Date 2023-12-12 Time 09:43 Sent To  
Notes
2023-12-12 09:45:16VOICE AND DATA OK JL

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-07-18 Cont ID  
Sent By clfranci Date 2023-07-18 Time   Rev Time 0.00
Received By clfranci Date 2023-07-18 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-05-30 Cont ID  
Sent By clfranci Date 2023-05-30 Time   Rev Time 0.00
Received By clfranci Date 2023-05-30 Time   Sent To  
Notes
2023-05-30 12:12:36THIS PLAN WAS REVIEWED AND APPROVED BY CAITLIN L
 FRANCIS, FIRE INVESTIGATOR, WITH THE FOLLOWING
 COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) THE LIFE SAFETY PLAN INDICATES THERE WILL BE A FIRE
 EXTINGUISHER BUT NONE ARE SHOWN ON THE PLAN. ENSURE
 THERE IS FIRE EXGUISHER ON SITE PER NFPA 101.
  
 CAITLIN L FRANCIS
 FIRE INVESTIGATOR
 WEST PALM BEACH FIRE RESCUE
 561.804.4728
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-08-07 Cont ID  
Sent By hmoser Date 2023-08-07 Time 12:54 Rev Time 0.00
Received By hmoser Date 2023-07-17 Time 08:48 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-06-29 Cont ID  
Sent By hmoser Date 2023-06-29 Time 15:39 Rev Time 0.00
Received By hmoser Date 2023-05-26 Time 09:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-08-07 Cont ID  
Sent By hmoser Date 2023-08-07 Time 11:23 Rev Time 0.00
Received By hmoser Date 2023-08-07 Time 11:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-06-29 Cont ID  
Sent By hmoser Date 2023-06-29 Time 15:39 Rev Time 0.00
Received By hmoser Date 2023-06-29 Time 14:53 Sent To  
Notes
2023-06-29 15:38:55PLAN DENIED
 PROVIDE COMPLETE ADDRESS AND SUITE NUMBER ON PLAN.
 SECTION 107 FBC
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop MEDGAS MEDICAL GAS
Rev No 2 Status P Date 2023-07-19 Cont ID  
Sent By rwbrown Date 2023-07-19 Time 06:00 Rev Time 0.00
Received By rwbrown Date 2023-07-19 Time 06:00 Sent To  
Notes
***NONE***

Review Stop MEDGAS MEDICAL GAS
Rev No 1 Status P Date 2023-06-16 Cont ID  
Sent By rwbrown Date 2023-06-16 Time 08:00 Rev Time 0.00
Received By rwbrown Date 2023-06-16 Time 08:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-07-19 Cont ID  
Sent By rwbrown Date 2023-07-19 Time 05:57 Rev Time 0.00
Received By rwbrown Date 2023-07-19 Time 05:57 Sent To  
Notes
2023-07-19 05:58:432ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. NOT ADDRESSED. A MIXING VALVE MEETING THE ASSE 1017
 STANDARD MUST BE INSTALLED AT THE WATER HEATER.
 2020 FPC 607.1.1/613.1 - HOT WATER DELIVERY - PER THIS
 SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT
 SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER
 DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE.
 THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE
 INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1.
 THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC
 HANDWASHING PROTECTION FOR TEMPERED WATER. PLEASE SHOW
 A WATER HEATER DETAIL THAT INCLUDES THE REQUIRED ASSE
 1017 MIXING DEVICE.
  
 2. DONE
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-06-16 Cont ID  
Sent By rwbrown Date 2023-06-16 Time 07:59 Rev Time 0.00
Received By rwbrown Date 2023-06-16 Time 07:59 Sent To  
Notes
2023-06-16 08:00:531ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 607.1.1/613.1 - HOT WATER DELIVERY - PER
 THIS SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT
 SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER
 DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE.
 THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE
 INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1.
 THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC
 HANDWASHING PROTECTION FOR TEMPERED WATER. PLEASE SHOW
 A WATER HEATER DETAIL THAT INCLUDES THE REQUIRED ASSE
 1017 MIXING DEVICE.
  
 2. 2020 FPC 607.1.2/419.5 - PLEASE SHOW A DETAIL THAT
 HAS THE REQUIRED ASSE 1070 MIXING DEVICE AT THE PUBLIC
 LAVATORY.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-07-19 Cont ID  
Sent By rwbrown Date 2023-07-19 Time 06:02 Rev Time 0.00
Received By rwbrown Date 2023-07-19 Time 06:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-06-21 Cont ID  
Sent By mpeterso Date 2023-06-21 Time 14:24 Rev Time 0.00
Received By mpeterso Date 2023-06-21 Time 14:24 Sent To  
Notes
***NONE***