Plan Review Details - Permit 23050007
Plan Review Stops For Permit 23050007
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-07-05 Cont ID  
Sent By lbond Date 2023-05-23 Time 12:50 Rev Time 0.00
Received By lbond Date 2023-05-23 Time 12:50 Sent To  
Notes
2023-07-05 09:40:49PERMIT- 23050007
 7.5.2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
 FHDA- FAIR HOUSING DESIGN ACT MANUAL
  
 PLAN REVIEW RESULTS: DENIED.
  
  
  
 1. [FBC 1207.3] STRUCTURE-BORNE SOUND. FLOOR/CEILING
 ASSEMBLIES
 BETWEEN DWELLING UNITS AND SLEEPING UNITS OR BETWEEN A
 DWELLING
 UNIT OR SLEEPING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN
 THE STRUCTURE SHALL HAVE AN IMPACT INSULATION CLASS
 RATING OF
 NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED,
 WHEN TESTED
 IN ACCORDANCE WITH ASTM E492.
  
 2. [FBC 603.1] ALLOWABLE MATERIALS IN NON-COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723.
  
 WHISPERMAT CS IS UNIQUELY APPROVED FOR TILE USE. THIS
 TYPE OF UNDERLAYMENT WILL NOT BE APPROVED FOR
 ENGINEERED WOOD AS INDICATED ON YOUR PLANS.
 PROVIDECORRECT UNDERLAYMENT APPROVED FOR THIS TYPE OF
 INSTALLATION. WHISPERMAT HW OR SIMILAR RECOMMEDED.
  
 3. FBC [A]109.1 VALUE : ITEMIZED THE COST OF MATERIAL
 AND LABOR BY A PROFESSIONAL FLORIDA LICENSED CONTRACTOR
 TO DO THIS INSTALLATION AND ADJUST THE VALUE OF THIS
 PERMIT ON YOUR APPLICATION.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-16 Cont ID  
Sent By lbond Date 2023-05-16 Time 11:35 Rev Time 0.00
Received By lbond Date 2023-05-16 Time 11:35 Sent To  
Notes
2023-05-16 11:38:37COMMENTS:BUILDING FAILED
  
 W.P.B. PERMIT: 23050007
  
 REVIEWED: 05.15.2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
 SECTION 107.2.1 WPB
 1)THE PLANS SHALL BEAR THE PRINTED NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE REMODEL.
 PLEASE PROVIDE THE TYPE OR LAMINATE AND UNDERLAYMENT
 FOR THE PROPOSED FLOORING LAYOUT TAKING INTO
 CONSIDERATION THE FIRE COMMENTS AND RESUBMIT WITH A
 SIGNED PLAN BY THE LICENSED CONTRACTOR WHO WILL BE
 DOING THE INSTALLATIOBUILDING REVIEW
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-19 Cont ID  
Sent By pleduc Date 2023-05-19 Time   Rev Time 0.00
Received By pleduc Date 2023-05-19 Time 14:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-05-04 Cont ID  
Sent By pleduc Date 2023-05-04 Time 15:31 Rev Time 0.00
Received By pleduc Date 2023-05-04 Time 15:31 Sent To  
Notes
2023-05-04 15:33:45THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS NO INDICATION OF A MANUFACTURER'S
 SPECIFICATION SHEET NOR A PRODUCT NAME FOR THE PROPOSED
 LAMINATE FLOORING NOR SOUND UNDERLAYMENT.
  
 LAMINATE FLOORING IS MANUFACTURED AROUND THE WORLD BUT
 NOT ALL ARE TESTED AND MEETING LISTED AND NFPA
 STANDARDS.
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE LAMINATE
 FLOORING & UNDERLAYMENT NAMSE AND THE PRODUCT SPEC
 SHEETS INDICATING THE FIRE BEHAVIOR RATING.
  
 IF THE PROPOSED FLOORING IS PORCELAIN/CERAMIC TILE,
 NATURAL STONE TILE, CONCRETE TILES, PRODUCT SPEC SHEETS
 WOULD NOT BE REQUIRED.
  
 PRODUCT SPEC SHEETS ARE REQUIRED FOR LVT, VINYL
 FLOORING, WOOD/VINYL LAMINATES, ETC.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-23 Cont ID  
Sent By lbond Date 2023-05-23 Time 12:50 Rev Time 0.00
Received By lbond Date 2023-05-18 Time 10:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-16 Cont ID  
Sent By lmarchan Date 2023-05-16 Time 11:46 Rev Time 0.00
Received By lmarchan Date 2023-05-03 Time 13:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-05-16 Cont ID  
Sent By lbond Date 2023-05-16 Time 11:36 Rev Time 0.00
Received By lbond Date 2023-05-16 Time 11:36 Sent To  
Notes
***NONE***