| 2023-05-31 13:54:16 | RESIDENTIAL(R3) RE-ROOF SECOND BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | PERMIT #23041431 |
| | 2737 S FLAGLER DR |
| | |
| | 1- FLAT ROOF FLORIDA PRODUCT APPROVAL: |
| | ORIGINAL COMMENT: |
| | A)CLEARLY MARK WHICH APPROVED ASSEMBLY IS GOING TO BE |
| | INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN |
| | PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. |
| | NOTE: PLEASE UPLOAD THE FLORIDA PRODUCT APPROVAL COVER |
| | PAGE AND INSTALLATION INSTRUCTIONS ON THE SAME PDF. |
| | |
| | RESPONSE: |
| | INFORMATION UPLOADED TO PROJECTDOX ON 05/26/23 IS |
| | MISMATCHING TWO DIFFERENT PRODUCT APPROVALS. CONTRACTOR |
| | UPLOADED THE REVISED PRODUCT APPROVAL COVER PAGE |
| | FL2533-R29 BUT THE INSTALLATION INSTRUCTIONS SUBMITTED |
| | ARE FOR THE OLD REVISION FL2533-R28. SELECTED SYSTEM |
| | W-67 IS NOT THE SAME FOR FL2533-R28 AND FL2533-R289. |
| | NEED TO SUBMIT MATCHING FLORIDA PRODUCT APPROVAL COVER |
| | PAGE AND INSTALLATION INSTRUCTIONS TO AVOID |
| | CONFLICTS/DELAYS. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | ORIGINAL COMMENT: |
| | B)BASED ON OLD FLORIDA PRODUCT APPROVAL FL2533-R28 |
| | SUBMITTED, IT LOOKS LIKE THE PROPOSED ASSEMBLY IS W-68. |
| | NEED TO PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS |
| | AS REQUIRED BY LIMITATION #5.7.2 OF PRODUCT APPROVAL |
| | SUBMITTED. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | RESPONSE: |
| | COORDINATE WITH ITEM ABOVE. MISMATCHING TWO DIFFERENT |
| | PRODUCT APPROVALS. |
| | |
| | ORIGINAL COMMENT: |
| | 2- HIP AND RIDGE TILE INSTALLATION. PROVIDE COMPLETE |
| | DETAILS AND SPECIFICATIONS FOR HIP AND RIDGE |
| | INSTALLATION AS REQUIRED BY SEC. R905.3.7.1 |
| | FBC-RESIDENTIAL. PROVIDE SPECIFICATIONS IN ACCORDANCE |
| | WITH FRSA/TRI FLORIDA HIGH WIND CONCRETE AND CLAY TILE |
| | INSTALLATION MANUAL (6TH EDITION) OR THE |
| | RECOMMENDATIONS OF RAS 118, 119 OR 120. |
| | ALTERNATIVE: IF USING METAL SUPPORT, THEN PROVIDE |
| | PRODUCT APPROVAL FOR HIP AND RIDGE METAL SUPPORT AND |
| | CLEARLY MARK ATTACHMENT METHOD. |
| | |
| | RESPONSE: |
| | REPEAT COMMENT. NOT ADDRESSED. |
| | |
| | NEW COMMENTS BASED ON INFORAMTION SUBMITTED: |
| | 3- ENGINEER TO REVISE THE ROOF COVERINGS ATTACHMENT |
| | CALCULATIONS SUBMITTED: |
| | A) COORDINATE SELECTED ASSEMBLY WITH CURRENT REVISED |
| | PRODUCT APPROVAL FL2533-R29. SEE ITEM #1(A) ABOVE. |
| | |
| | B)ENGINEER TO PROVIDE SKETCH SHOWING HOW THE PROPOSED |
| | NAILS ARE GOING TO BE INSTALLED FOR THE SEVEN CENTER |
| | ROWS IN ZONE 3. NEED TO VERIFY THAT FASTENER SEPARATION |
| | IS NOT LESS THAN 4"O.C. AS REQUIRED BY SEC. 8.1 OF RAS |
| | 117. |
| | SEC. 107.2.1.2 CITY AMENDMENTS. |
| | |
| | C)ENGINEER'S DIGITAL SIGNATURE DOESN'T COMPLY WITH THE |
| | REQUIREMENTS OF FBPE. NEED A SEPARATE TEXT BOX WITH THE |
| | TEXT BOX LANGUAGE IDENTICAL TO THE SAMPLES SHOWN BY |
| | FBPE. |
| | SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU |
| | MENTS/??? AND REVISE DIGITAL SIGNATURE AS REQUIRED. |
| | |
| | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND |
| | SEALING ELECTRONICALLY TRANSMITTED PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| | |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |