Plan Review Details - Permit 23041415
Plan Review Stops For Permit 23041415
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2023-05-02 Cont ID  
Sent By lbond Date 2023-05-02 Time 12:04 Rev Time 0.00
Received By lbond Date 2023-05-02 Time 12:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-05-02 Cont ID  
Sent By lbond Date 2023-05-02 Time 12:16 Rev Time 0.00
Received By lbond Date 2023-05-02 Time 12:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-07-14 Cont ID  
Sent By rperdomo Date 2023-07-14 Time 16:53 Rev Time 0.00
Received By rperdomo Date 2023-07-14 Time 16:53 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-07-07 Cont ID  
Sent By rperdomo Date 2023-07-07 Time 16:13 Rev Time 0.00
Received By rperdomo Date 2023-07-07 Time 16:03 Sent To  
Notes
2023-07-07 16:12:59FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE A ONE-LINE DIAGRAM SHOWING INFORMATION OF
 SERVICE EQUIPMENT (SERVICE CONDUCTORS, SERVICE
 OVERCURRENT PROTECTION) AS PER NEC 220, 230, 250
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-05-15 Cont ID  
Sent By rperdomo Date 2023-05-15 Time 16:41 Rev Time 0.00
Received By rperdomo Date 2023-05-15 Time 16:35 Sent To  
Notes
2023-05-15 16:40:23FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE A ONE-LINE DIAGRAM SHOWING INFORMATION OF
 SERVICE EQUIPMENT (SERVICE CONDUCTORS, SERVICE
 OVERCURRENT PROTECTION) AS PER NEC 220, 230, 250
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-07-03 Cont ID  
Sent By clfranci Date 2023-07-03 Time   Rev Time 0.00
Received By clfranci Date 2023-07-03 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-05-01 Cont ID  
Sent By clfranci Date 2023-05-01 Time   Rev Time 0.00
Received By clfranci Date 2023-05-01 Time   Sent To  
Notes
2023-05-01 09:22:38THIS PLAN WAS REVIEWED AND FAILED BY CAITLIN L FRANCIS,
 FIRE INVESTIGATOR, WITH THE FOLLOWING COMMENTS:
  
 1) THERE ARE INDICATIONS OF FLOOR UNDERLAYMENT AND
 VINYL FLOORING BUT NO SPECIFICATIONS SHEETS THAT
 INDICATE MEETING THE REQUIREMENTS PER NFPA'
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7* INTERIOR FLOOR FINISH TESTING AND
 CLASSIFICATION.
 10.2.7.1* CARPET AND CARPET LIKE INTERIOR FLOOR
 FINISHES SHALL
 COMPLY WITH ASTM D 2859, STANDARD TEST METHOD FOR
 IGNITION
 CHARACTERISTICS OF FINISHED TEXTILE FLOOR COVERING
 MATERIALS.
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 10.2.7.4 INTERIOR FLOOR FINISHES SHALL BE GROUPED IN
 THE CLASSES SPECIFIED
 IN 10.2.7.4.1 AND 10.2.7.4.2 IN ACCORDANCE WITH THE
 CRITICAL RADIANT FLUX
 REQUIREMENTS.
 10.2.7.4.1 CLASS I INTERIOR FLOOR FINISH. CLASS I
 INTERIOR FLOOR FINISH
 SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN
 0.45 W/CM2, AS DETERMINED
 BY THE TEST DESCRIBED IN 10.2.7.3.
 10.2.7.4.2 CLASS II INTERIOR FLOOR FINISH. CLASS II
 INTERIOR FLOOR FINISH
 SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN
 0.22 W/CM2, BUT LESS
 THAN 0.45 W/CM2, AS DETERMINED BY THE TEST DESCRIBED IN
 10.2.7.3.
  
 PLEASE REVIEW AND PROVIDE SPEC SHEETS.
  
  
 2) THERE ARE INDICATIONS OF WALL AND FLOOR DEMO AND
 PAINTING.
  
 ANY WORK INVOLVING FIRE SPRINKLERS/FIRE ALARM SYSTEMS
 OR EQUIPMENT SHALL BE DONE UNDER SEPARATE PERMITS AND
 SHOP DRAWINGS.
  
 FIRE SPRINKLERS AND FIRE ALARM EQUIPMENT SHALL BE
 PROTECTED FROM PAINTING OR DAMAGE.
  
 THE FIRE SPRINKLER/FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO AND RECONSTRUCTION.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT AND ENSURE
 COMPLIANCE.
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 CAITLIN L FRANCIS
 FIRE INVESTIGATOR
 561-804-4728
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-10 Cont ID  
Sent By aoliver Date 2023-07-10 Time 07:07 Rev Time 0.00
Received By aoliver Date 2023-06-30 Time 09:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-19 Cont ID  
Sent By hmoser Date 2023-05-19 Time 14:57 Rev Time 0.00
Received By hmoser Date 2023-04-28 Time 12:24 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-05-19 Cont ID  
Sent By hmoser Date 2023-05-19 Time 14:53 Rev Time 0.00
Received By hmoser Date 2023-05-19 Time 14:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-05-08 Cont ID  
Sent By rwbrown Date 2023-05-08 Time 07:26 Rev Time 0.00
Received By rwbrown Date 2023-05-08 Time 07:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-02 Cont ID  
Sent By lbond Date 2023-05-02 Time 12:16 Rev Time 0.00
Received By lbond Date 2023-05-02 Time 12:16 Sent To  
Notes
***NONE***