Plan Review Details - Permit 23041353
| Plan Review Stops For Permit 23041353 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-18 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-15 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-11 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-03 |
Time |
08:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-18 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-18 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-18 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2023-05-18 10:00:40 | PLAN PASS PROVISO | | | PROVIED AHRI SHEET ON ALL NEW AIR CONDITIONING | | | EQUIPMENT | | | OR PROVIDE EQUIPMENT SCHEDULE ON PLAN REVISION WOULD BE | | | REQUIRED. BEFOR ROUGH INSPECTION. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-11 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-11 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2023-05-11 16:39:41 | 1ST REVIEW FMC | | | PERMIT: 23041353 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) EXISTING HP-2 WAS A 4-TON ON THE PREVIOUS DRAWING, | | | IT IS NOW A 5-TON. | | | EXISTING HP-3 WAS A1.5 TON ON THE PREVIOUS DRAWING, IT | | | IS NOW A 4-TON. PROVIDE MECHANICAL EQUIPMENT SIZING | | | CALCULATIONS FOR THESE CHANGES. FEC C403.2.1 | | | | | | 2) IT APPEARS THE DUCT WORK FOR AHU-8 HAS BEEN | | | REROUTED. WHAT IS THIS MDF CLOSET AND WHY DOES IT NOT | | | NEED OUTDOOR AIR? FMC 403.3.1.1 | | | | | | 3) PROVIDE THE AIRFLOW FOR THE HP-8. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-11 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-11 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
|