Plan Review Details - Permit 23041300
Plan Review Stops For Permit 23041300
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-06-20 Cont ID  
Sent By jwitmer Date 2023-06-20 Time 10:48 Rev Time 0.00
Received By jwitmer Date 2023-06-20 Time 07:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-24 Cont ID  
Sent By jwitmer Date 2023-05-24 Time 09:10 Rev Time 0.00
Received By jwitmer Date 2023-05-24 Time 07:01 Sent To  
Notes
2023-05-24 09:15:47WEST PALM BEACH DEVELOPMENT SERVICES
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W.P.B. SUBMITTAL: 23041300
 W. P. B. PERMIT: 22101425 / 22101430
 ADD: 550 EXECUTIVE CENTER DR.
 CONT: LEGACY CONSTRUCTION
 TEL: 218-297-2170
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MAY 24, 2023
 ACTION: DENIED
  
 1A) THIS SUBMITTAL WAS BROUGHT IN FOR ONE BUILDING ONLY
 NOT SHOWN ON THE SUBMITTAL SHEET PERMIT 23041300!!!!!
  
 1B) LEGACY CONSTRUCTION SUBMITTAL #8.3-1.0 WINDOWS AND
 PATIO DOORS & 8.3- WINDOWS. COVER SHEET STATES SPEC
 SECTION IS 8.3 WINDOWS 12-20-2022 WHERE IS THE SECTION
 8.3-1.0? ADDITIONAL INFORMATION IS REQUIRED.
  
 2) NOT INCLUDE IN THIS SUBMITTAL IS SHEET A-900 WINDOW
 AND DOORS WITH WIND DESIGN CRITERIA AND ASSOCIATED
 PRESSURES. 2020 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION
 107.2.1. CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL.
  
 3)MISSING NOT COMPLETED IN ANY OF THE PRODUCT
 APPROVALS. IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY
 IN THE PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER
 OF RECORD AND BEFORE SUBMISSION TO THE BUILDING
 DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE
 IDENTIFY THE OPENING WIDTH & HEIGHT, SILL HEIGTH, TYPE
 OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR
 REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER???S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 4) MISSING IN THE SLIDING GLASS NOA 22-1205.01 IS AS
 STATED ABOVE THE SILL HEIGHT FOR THE SLIDING GLASS
 DOORS IN ACCORDANCE WITH 2020 FBC-B HABITAL SPACES/
 1709.5.1.1FBC-B EXTERIOR WINDOWS AND DOORS. (EXCEPTION)
 2. DOOR ASSEMBLIES INSTALLED WHERE THE OVERHANG (OH)
 RATIO IS EQUAL TO OR MORE THAN 1 NEED NOT BE TESTED FOR
 WATER INFILTRATION. THE OVERHANG RATIO SHALL BE
 CALCULATED BY THE FOLLOWING EQUATION:
 OH RATIO = OH LENGTH/OH HEIGHT
 WHERE:
 OH LENGTH = THE HORIZONTAL MEASURE OF HOW FAR AN
 OVERHANG OVER A DOOR PROJECTS OUT FROM DOOR SURFACE.
 OH HEIGHT = THE VERTICAL MEASURE OF THE DISTANCE FROM
 THE DOOR SILL TO THE BOTTOM OF THE OVERHANG OVER A
 DOOR.
  
 TECHNICAL SHEET 7 OF 21 FIGURE 1 PROVIDES THE EXAMPLE
 OF OVERHANG LENGTH VERSES WALL HEIGHT. TABLE 1 POSITIVE
 PRESSURES THE MINIMUM SILL HEIGHT REQUIRED WOULD BE 3
 ?? INCHES GOOD FOR +60.0 PSF, THE 2 ?? INCH SILL HEIGHT
 IS GOOD FOR + 38.7 NOT MEETING THE REQUIRED + 47.1 PSF.
  
 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
  
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-06-16 Cont ID  
Sent By pleduc Date 2023-06-16 Time   Rev Time 0.00
Received By pleduc Date 2023-06-16 Time 09:17 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-05-19 Cont ID  
Sent By cwalker Date 2023-05-19 Time   Rev Time 0.00
Received By pleduc Date 2023-05-19 Time 11:42 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2023-06-20 Time   Rev Time 0.00
Received By amcgrego Date 2023-06-15 Time 08:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2023-05-24 Time   Rev Time 0.00
Received By amcgrego Date 2023-05-17 Time 10:51 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-06-20 Cont ID  
Sent By jwitmer Date 2023-06-20 Time 10:49 Rev Time 0.00
Received By jwitmer Date 2023-06-20 Time 10:49 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-05-24 Cont ID  
Sent By jwitmer Date 2023-05-24 Time 09:14 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2023-05-24 09:14:21LAKESIE COMMONS WIND DESIGN CALCULATIONS DOES NOT MEET
 DIGITAL SIGNATURE REQUIREMENTS OF OPENING FOR REVIEW BY
 THIRD PARTY.
 FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) PLANS
 IN THE FILE FOLDER, SCANNED, FACSIMILE, DIGITALLY
 CREATED OR COPIED IMAGE OF THE LICENSEE???S SIGNATURE
 SHALL NOT BE USED ON ELECTRONIC/DIGITALLY SIGNED AND
 SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR
 OTHER DOCUMENTS.
  
  
  
 FL. ADMINISTRATIVE CODE 61G15-23.004 PROCEDURES FOR
 SIGNING AND SEALING ELECTRONICALLY TRANSMITTED PLANS
 (DIGITAL SIGNATURES), SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS, REQUIRE 3RD PARTY VERIFICATION.
 1) ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN
 ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025,
 F.S., AND RULE 61G15-23.001, F.A.C., MAY BE SIGNED
 DIGITALLY AS PROVIDED HEREIN BY THE PROFESSIONAL
 ENGINEER IN RESPONSIBLE CHARGE. AS USED HEREIN, THE
 TERMS ???CERTIFICATION AUTHORITY,??? AND ???DIGITAL
 SIGNATURE??? SHALL HAVE THE MEANINGS ASCRIBED TO THEM
 IN SECTIONS 668.003(2) AND (3), F.S.
  