Plan Review Details - Permit 23041277
Plan Review Stops For Permit 23041277
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-07-25 Cont ID  
Sent By dbattles Date 2023-07-25 Time 16:58 Rev Time 0.00
Received By dbattles Date 2023-07-25 Time 16:58 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-07-03 Cont ID  
Sent By jwitmer Date 2023-07-03 Time 16:13 Rev Time 0.00
Received By jwitmer Date 2023-07-03 Time 15:56 Sent To  
Notes
2023-07-03 16:13:48COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING
 THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS
 PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM
 BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION
 WILL BE GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-07-03 Cont ID  
Sent By jwitmer Date 2023-07-03 Time 16:24 Rev Time 0.00
Received By jwitmer Date 2023-07-03 Time 15:40 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-07-05 Cont ID  
Sent By mpeterso Date 2023-07-05 Time 13:22 Rev Time 0.00
Received By mpeterso Date 2023-07-05 Time 13:22 Sent To  
Notes
2023-07-05 13:25:45ELECTRIC REVIEW FAILED
  
 1) ROOMS LABELED WORKROOM A, B AND BACK BAR APPEAR TO
 BE CLASSIFIED AS A KITCHEN IN ACCORDANCE WITH NEC 100
 DEFINITIONS. EQUIPMENT DETAILED ON KITCHEN EQUIPMENT
 SCHEDULE DETAIL THEY ARE TO TERMINATE TO RECEPTACLES
 WHICH ARE REQUIRED TO BE GFIC PROTECTED IN ACCORDANCE
 WITH NEC 210.8. PLEASE CORRECT PLANS TO INDICATE ALL
 RECEPTACLES LOCATED IN THESE KITCHEN AREAS COMPLY WITH
 NEC 210.8
  
 NEC 210.8 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION
 FOR PERSONNEL
 (B) OTHER THAN DWELLING UNITS.
 ALL SINGLE-PHASE RECEPTACLES RATED 150 VOLTS TO GROUND
 OR LESS, 50 AMPERES OR LESS AND THREE-PHASE RECEPTACLES
 RATED 150 VOLTS TO GROUND OR LESS, 100 AMPERES OR LESS
 INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE
 GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR
 PERSONNEL.
 (2) KITCHENS
  
 NEC 100 DEFINITIONS
 KITCHEN.
 AN AREA WITH A SINK AND PERMANENT PROVISIONS FOR FOOD
 PREPARATION AND COOKING
  
 3) SHEET E202 REFERS, INCORRECTLY TO A DETAIL ON SHEET
 E 301 DETAIL 7 THAT APPEARS TO BE SHOWN ON SHEET E 302
 DETAIL 7. PLEASE CORRECT AS APPLICABLE. FBC 107.2
  
 4) SHEET E 303 DETAIL 2, BANQUET CLOSTER INDICATES A
 DIMMED DUPLEX RECEPTACLE. NEC 404.14 STATES GENERAL USE
 DIMMER SWITCHES SHALL ONLY BE USED TO CONTROL PERMANTLY
 INSTALLED LUMINAIRES. PLEASE CORRECT AS APPLICABLE.
  
 NEC 404.14 RATING AND USE OF SWITCHES.
 (E) DIMMER SWITCHES.
 GENERAL-USE DIMMER SWITCHES SHALL BE USED ONLY TO
 CONTROL PERMANENTLY INSTALLED INCANDESCENT LUMINAIRES
 UNLESS LISTED FOR THE CONTROL OF OTHER LOADS AND
 INSTALLED ACCORDINGLY.
  
 5) PLEASE INDICATE TAMPER RESISTANT RECEPTACLES IN ALL
 APPLICABLE LOCATIONS, IN ACCORDANCE WITH NEC 406.12(6)
 REFERRED TO IN 518.2 ASSEMBLY AREAS.
  
 406.12 TAMPER-RESISTANT RECEPTACLES.
 ALL 15- AND 20-AMPERE, 125- AND 250-VOLT
 NONLOCKING-TYPE RECEPTACLES IN THE AREAS SPECIFIED IN
 406.12(1) THROUGH (7) SHALL BE LISTED TAMPER-RESISTANT
 RECEPTACLES.
 (6) SUBSET OF ASSEMBLY OCCUPANCIES DESCRIBED IN 518.2
 TO INCLUDE PLACES OF WAITING TRANSPORTATION,
 GYMNASIUMS, SKATING RINKS, AND AUDITORIUMS
  
 2) PLEASE PROVIDE A NOTE STATING SIGNS AND ALL LOW
 VOLTAGE WIRING INCLUDING BUT NOT LIMITED TO, VOICE,
 DATA, AUDIO, VIDEO, SECURITY, ACCESS, POS, FIRE ALARM,
 ETC. REQUIRE A SEPARATE PERMIT.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-06-15 Cont ID  
Sent By pleduc Date 2023-06-15 Time   Rev Time 0.00
Received By pleduc Date 2023-06-14 Time 15:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-26 Time 15:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-07-15 Cont ID  
Sent By hmoser Date 2023-07-15 Time 09:29 Rev Time 0.00
Received By hmoser Date 2023-06-13 Time 12:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-15 Cont ID  
Sent By hmoser Date 2023-07-15 Time 09:29 Rev Time 0.00
Received By hmoser Date 2023-07-15 Time 09:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-07-27 Cont ID  
Sent By ccole Date 2023-07-27 Time 10:34 Rev Time 0.00
Received By ccole Date 2023-07-27 Time 08:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-07-03 Cont ID  
Sent By ccole Date 2023-07-03 Time 11:17 Rev Time 0.00
Received By ccole Date 2023-07-03 Time 09:19 Sent To  
Notes
2023-07-03 11:19:151ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23041277
 7/3/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P201 & P301: PLEASE NOTE THE GREASE
 INTERCEPTOR SHALL RECEIVE WASTE ONLY FROM FIXTURES AND
 EQUIPMENT THAT ALLOW FATS, OILS, AND GREASE TO BE
 DISCHARGED- SEC. 1003.3.1 FBC P. THE PLANS APPEAR TO
 SHOW DRAINAGE FROM HAND SINKS (P14688) AND FLOOR SINKS
 BELOW ICE BINS DRAINING INTO THE GREASE WASTE LINE
 WHICH IS NOT ALLOWED.
  
 2) P201 & P301: ITEMS 15186 & 19742 SHOWN ON THE PLANS
 ARE NOT SHOWN IN THE SCHEDULE- SEC. 107.2.1 WPB &
 1003.3.1 FBC P. IT APPEARS THE 3-COMPARTMENT SINK IS
 NOT IDENTIFIED.
  
 3) P402: PLEASE PROVIDE GREASE WASTE CALCULATIONS IN
 ACCORDANCE WITH SEC. 1003.3.5 FBC P.
  
 4) A SEPARATE PERMIT IS REQUIRED FOR INSTALLATION OF
 THE GREASE INTERCEPTOR HOWEVER THE PERMIT APPLICATION
 IS REQUIRED TO BE SUBMITTED PRIOR TO THE MAIN PLUMBING
 PLAN APPROVAL. YOU CAN SUBMIT AN APPLICATION ???TBD???
 (TO BE DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR
 SELECTED BY EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL
 CHANGE THE REVIEW STATUS TO PASS.
  
 5) P202 & P301: SHOW THE LOCATIONS OF REQUIRED INLINE
 BACKFLOW PREVENTERS FOR WATER SUPPLY LINES TO COFFEE
 AND EXPRESSO MACHINES, ICE MAKERS, FILTER SYSTEMS ETC-
 SEC. 608.3 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2023-07-25 Cont ID  
Sent By dbattles Date 2023-07-25 Time 16:52 Rev Time 0.00
Received By dbattles Date 2023-07-25 Time 16:52 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By dbattles Date 2023-05-02 Time 14:22 Rev Time 0.00
Received By dbattles Date 2023-05-02 Time 14:22 Sent To  
Notes
2023-05-02 14:23:36CERTIFICATE OF INSURANCE FOR PROFESSIONAL LIABILITY OF
 FIRM. MINIMUM COVERAGE OF $1,000,000.00 PER OCCURRENCE
 AND $2,000,000.00 AGGREGATE ARE REQUIRED. F.S. 553.791
 (4) (B) AND (16). CERTIFICATE OF INSURANCE FOR
 PROFESSIONAL LIABILITY OF FIRM. MINIMUM COVERAGE OF
 $1,000,000.00 PER OCCURRENCE AND $2,000,000.00
 AGGREGATE ARE REQUIRED. F.S. 553.791 (4) (B) AND (16).
 IN THE DESCRIPTION OF OPERATIONS PLEASE ADD LANGUAGE TO
 STATE "THE PROFESSIONAL LIABILITY POLICY INCLUDES AN
 EXTENDED REPORTING PERIOD ENDORSEMENT (TAIL COVERAGE)
 FOR FIVE YEARS. ___________IS PROVIDING PROFESSIONAL
 LIABILITY INSURANCE COVERING ALL SERVICES TO BE
 PERFORMED AS A PRIVATE PROVIDER.
  
 QULIFICATIONS
 - PLEASE PROVIDE QUALIFICATIONS FOR REVIEWERS OR
 INSPECTORS WITH THEIR LICENSES.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-05 Cont ID  
Sent By mpeterso Date 2023-07-05 Time 13:27 Rev Time 0.00
Received By mpeterso Date 2023-07-05 Time 13:27 Sent To  
Notes
2023-07-05 13:27:53ALL PLANS PASSED SIGNATURE REVIEW. MP
2023-07-03 16:25:59ARCHITECTURAL SHEETS SIGNATURE GOOD. JWITMER 07-03-23
2023-07-03 09:47:30PLUMBING PLAN SIGS APPROVED.

Review Stop Z ZONING
Rev No 1 Status N Date 2023-06-30 Cont ID  
Sent By lgelman Date 2023-06-30 Time 20:09 Rev Time 0.00
Received By rbrown Date 2023-06-30 Time 20:09 Sent To  
Notes
***NONE***