Plan Review Details - Permit 23041215
| Plan Review Stops For Permit 23041215 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-05-11 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-05-11 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-02 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-05-02 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2023-05-02 14:07:54 | PLAN REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | REVISION DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) IN SECTION II, THE ENGINEER'S CALCULATIONS FOR THE | | | NUMBER OF FASTENERS FOR ZONE 2 ARE INCORRECT. THE | | | CALCULATION HAS 20.86447 FASTENERS THIS SHOULD BE | | | ROUNDED UP TO 21 FASTENERS AND 20 ARE SPECIFIED. PLEASE | | | CORRECT. | | | | | | 2) IN SECTION II, THE ENGINEER'S CALCULATIONS FOR THE | | | NUMBER OF FASTENERS FOR ZONE 3 ARE INCORRECT. THE | | | CALCULATION HAS 28.60073 FASTENERS THIS SHOULD BE | | | ROUNDED UP TO 29 FASTENERS AND 28 ARE SPECIFIED. PLEASE | | | CORRECT. | | | | | | 3) THE PROJECT ADDRESS ON THE CALCULATIONS IS NOT | | | CORRECT. THE NAME OF THE ROAD IS SPELLED WRONG. IT | | | SHOULD BE OKEECHOBEE ROAD. PLEASE CORRECT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-05-11 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-05-05 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-02 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-27 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-05-11 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-05-11 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-02 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-05-02 |
Time |
13:30 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |