| Plan Review Stops For Permit 23041206 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2023-05-02 10:01:57 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23041206 | | | | | | REVIEWED: MAY 2 2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: BUILDING PERMIT APPLICATON VALUE: FAILED | | | | | | SHEET SP-1 | | | | | | [A]109.1PAYMENT OF FEES. A PERMIT SHALL NOT BE VALID | | | UNTIL THE FEES PRESCRIBED BY LAW HAVE BEEN PAID, NOR | | | SHALL AN AMENDMENT TO A PERMIT BE RELEASED UNTIL THE | | | ADDITIONAL FEE, IF ANY, HAS BEEN PAID. | | | | | | SCOPE OF WORK INDICATES 596 S.F. + 365 S.F. NEW AREA | | | UNDER AC | | | ACCODING TO ICC R-3 VB THIS SHOULD COST MINIMUM | | | 156,998.57 @ 167.37 PER S.F. | | | | | | PERMIT VALUE AREA AND FEES MUST BE ADJUSTED | | | | | | | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
jcooley |
Date |
2023-05-11 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
jcooley |
Date |
2023-05-11 |
Time |
16:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2023-05-02 15:37:58 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 23041206 | | | 5/2/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET PG-1: PLEASE DO NOT USE THE PHRASE (EITHER OR) | | | CONCERNING THE TYPE OF GAS PIPING TO BE INSTALLED. EACH | | | TYPE OF PIPING HAS LIMITIATIONS OF USE. IDENTIFY OR | | | LABEL EACH SEGMENT OF PIPING SHOWN ON THE PLAN AND IN | | | THE RISER DRAWING- SECS. G2414.4 & G2414.6 FBC RES. | | | PLEASE NOTE UNPROTECTED STEEL PIPE SHALL NOT BE RUN | | | UNDERGROUND, AND PE PIPING SHALL NOT BE RUN UNDER ANY | | | BUILDING OR SLAB- SECS. G2415.11 & G2415.17.1. | | | | | | 2) PG-1: BASED ON THE SCHEDULE 40 METALLIC LOW PRESSURE | | | PIPE SIZING TABLE IN THE FBC RES- TABLES G2413.4(1) THE | | | ??-INCH PIPE SUPPLYING THE WATER HEATER SHALL BE | | | INCREASED TO 1-INCH. | | | | | | 3) PG-1: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | RANGE- SEC. G2407.1 FBC RES. IF USING THE STANDARD | | | INDOOR AIR METHOD THE MINIMUM REQUIRED VOLUME SHALL 50 | | | CU.FT. PER 1000 BTU OF THE RANGE INPUT RATING- SEC. | | | G2407.5 FBC RES. | | | | | | 4) PG-1: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | DRYER- SEC. G2407.1 FBC RES. PLEASE NOTE THE EXCEPTION | | | WHICH ALLOWS FOR MAKEUP AIR TO BE SUBSTITUTED IN | | | ACCORDANCE WITH SEC. G2439.5. | | | | | | 5) PG-1: SHOW A MINIMUM 4 FT. CLEARANCE FOR THE WATER | | | HEATER EXHAUST TO THE WINDOWS AND DOORS- SECS. G2427.8 | | | & G2448.1 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-07-28 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-17 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-04-26 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2023-05-02 09:52:59 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23041206 | | | | | | REVIEWED: MAY 2ND 2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-25 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-25 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-05-17 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-17 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-25 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2023-05-17 13:29:50 | PLAN DENIED | | | 1) PROVIDE DUCT SIZE ON ALL SUPPLY AND RETURN | | | AIR DUCT PER SECTION 107 CITY OF WEST PALM BEACH | | | AMENDMENTS. | | | 2) REFER TO SECTION M1502 CLOTHES DRYER EXHAUST | | | 2020 FBC RESIDENTIAL CODE. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-16 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
|
Date |
2023-08-08 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
|
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
|
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2023-05-02 14:47:02 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 23041206 | | | 5/2/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET PG-1: PROVIDE A TWO-WAY CLEANOUT WHERE THE | | | BUILDING DRAIN CONNECTS WITH THE SEWER LINE ON THE EAST | | | SIDE OF THE MOTHER-IN-LAW BEDROOM- SECS. P3005.2.3 & | | | P3005.2.8 FBC RES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
09:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
gvolcy |
Date |
2023-05-11 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-05-11 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2023-05-25 10:07:39 | 05.25.2023 - FAILED | | | | | | MAKE THE FOLLOWING NOTES ON PLANS: | | | | | | SF7 ZONING: NO SECONDARY KITCHEN AND MOTHER-IN-LAW | | | SUITE NOT INTENDED FOR RENT. | | | | | | REVIEWED BY: | | | GAISHA (ANNE) VOLCY | | | PLANNER | | | [email protected] |
|
|