Plan Review Details - Permit 23041178
Plan Review Stops For Permit 23041178
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-07-14 Cont ID  
Sent By cpuell Date 2023-07-14 Time 10:16 Rev Time 0.00
Received By cpuell Date 2023-07-14 Time 10:16 Sent To  
Notes
2023-07-14 10:17:15ADDRESS APPROPRIATE FOR PROJECT.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2023-07-25 Cont ID  
Sent By jwitmer Date 2023-07-25 Time 13:22 Rev Time 0.00
Received By jwitmer Date 2023-07-25 Time 11:18 Sent To  
Notes
2023-07-25 13:23:21SHELL PERMIT, 1ST BUILD-OUT NEW CONSTRUCTION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-07-25 Cont ID  
Sent By jwitmer Date 2023-07-25 Time 13:22 Rev Time 0.00
Received By jwitmer Date 2023-07-25 Time 11:18 Sent To  
Notes
2023-07-25 13:22:26WEST PALM BEACH DEVELOPMENT SERVICES
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 23041178
 ADD:624 7TH ST
 CONT: HARTNETT BUILDING GROUP
 TEL: 772-429-5243
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JULY 25/ 2023
 ACTION: DENIED
  
 1) SHEET A2-OB-2 TYPE B INTERIOR ELEVATIONS SHOWS A
 PASS-THROUGH OPENING, THE TOP OF SILL HEIGHT IS AT 4
 FEET ?? INCH ABOVE FINISH FLOOR. THIS PASS-THROUGH
 OPENING DOES NOT COMPLY WITH THE 2020 FBC-ACCESS. CODE
 SECTIONS 308 REACH RANGES. 308.2 FORWARD REACH. /
 308.2.1 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 2) SHEET A2-0 IT APPEARS AT THE END OF THE BUILDOUT BY
 THE EXTERIOR DOOR THERE APPEARS TO BE A SALES COUNTER.
 SHEET A2-0B-2 NOTE 16 IS A NOTE POS AREA (POINT OF
 SALE). THE CASH REGISTER STAND IS AT AN ELEVATION OF 3
 FEET 6 INCHES ABOVE FINISH FLOOR. 2020 FBC-ACCESS. CODE
 902.3 HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28
 INCHES MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 3) SHEET A2-OB-2 AT POS MISSING THE CLEAR FLOOR SPACE
 SEE 2020 FBC-ACCESS. CODE 902.2 CLEAR FLOOR OR GROUND
 SPACE. A CLEAR FLOOR SPACE COMPLYING WITH 305
 POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED.
 KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED.
  
 4) SHEET A2-0 IS MISSING THE TURNING SPACE AT THE
 PASS-THROUGH OPENING AND POS (POINT OF SALE) SALES
 COUNTER. 2020 FBC-ACCESS. CODE 304.3 SIZE, 304.3.1
 CIRCULAR AND 304.3.2 T-SHAPED.
  
 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
  
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By jleahy Date 2023-07-18 Time 14:53 Rev Time 0.00
Received By jleahy Date 2023-07-17 Time 11:29 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-07-12 Cont ID  
Sent By pleduc Date 2023-07-12 Time   Rev Time 0.00
Received By pleduc Date 2023-07-12 Time 16:17 Sent To  
Notes
2023-07-12 16:18:10FIRE PROVISO:
  
 THE HOOD & SUPPRESSION SYSTEMS SHALL BE
 INSTALLED UNDER SEPARATE PERMIT & SHOP
 DRAWINGS
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-07-17 Cont ID  
Sent By rwbrown Date 2023-07-17 Time 13:16 Rev Time 0.00
Received By rwbrown Date 2023-07-17 Time 13:16 Sent To  
Notes
2023-07-17 13:16:381ST GAS REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FGC 304.1 - PLEASE SHOW THE REQUIRED COMBUSTION
 AIR CALCULATIONS FOR THE APPLIANCES SHOWN ON THE PLAN.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop HIST HISTORICAL
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-06 Time 16:56 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-07-24 Cont ID  
Sent By hmoser Date 2023-07-24 Time 10:14 Rev Time 0.00
Received By hmoser Date 2023-07-24 Time 10:14 Sent To  
Notes
2023-07-24 10:17:00KITCHEN HOODS AND REFRIGERATION REQUIRE
 SEPARATE APPLICATION, PLAN AND PERMIT.

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-07-17 Cont ID  
Sent By rwbrown Date 2023-07-17 Time 13:15 Rev Time 0.00
Received By rwbrown Date 2023-07-17 Time 13:15 Sent To  
Notes
2023-07-17 13:16:091ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2020 FPC 607.1.1/613.1 - SHOW THE REQUIRED
 THERMOSTATIC MIXING DEVICE IN THE WATER HEATER PIPING
 DETAIL AND SHOW THAT ALL HOT WATER GOES THROUGH THE
 DEVICE. THIS DEVICE SHOULD MEET THE ASSE 1017 STANDARD.
  
 2. 2020 FPC 1003.3.1 - ONLY DEVICES DESIGNED TO RECEIVE
 FATS, OILS AND GREASE SHALL BE DIRECTED TO THE GREASE
 WASTE. PLEASE SHOW THAT THE ICE BIN, HAND SINKS AND
 OTHER DEVICES THAT ARE NOT DESIGNED TO RECEIVE F.O.G
 DISCHARGES ARE GOING TO THE SANITARY AND NOT TO THE
 GREASE WASTE.
  
 3. 2020 FPC 901.2.1 - - THE WATER CLOSET IN THE WOMEN'S
 IS NOT VENTED TO CODE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-07-18 Cont ID  
Sent By jleahy Date 2023-07-18 Time 14:54 Rev Time 0.00
Received By jleahy Date 2023-07-18 Time 14:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status   Date   Cont ID  
Sent By cibaven Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved