Plan Review Details - Permit 23041172
| Plan Review Stops For Permit 23041172 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-05-05 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-05 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-05 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-05-21 |
|
|
Cont ID |
|
| Sent By |
jcooley |
Date |
2023-05-21 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
jcooley |
Date |
2023-05-21 |
Time |
07:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
jcooley |
Date |
2023-05-11 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
jcooley |
Date |
2023-05-11 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2023-05-11 17:21:16 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE3602.3 | | | | | | | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | CODES IN EFFECT: | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | JONATHAN COOLEY | | | ELECTRICAL INSPECTOR | | | ELECTRICAL PLANS EXAMINER | | | (561)345-4377 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-22 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-18 |
Time |
17:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-05-12 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-05-04 |
Time |
11:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
P |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-05 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-05 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-22 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-22 |
Time |
08:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-05-05 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-05 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-05 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
|