| Plan Review Stops For Permit 23041074 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-22 |
Time |
18:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-22 |
Time |
18:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-04-25 |
Time |
18:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-04-25 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2023-04-25 18:49:01 | NOTE: | | | THE GENERATOR SHALL BE LOCATED A MINIMUM OF 10 FT. FROM | | | ANY OPENING INCLUDING WINDOWS, DOORS, ETC. SEC. | | | R303.5.1 FBC RES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-04-23 |
|
|
Cont ID |
|
| Sent By |
jcooley |
Date |
2023-04-23 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
jcooley |
Date |
2023-04-23 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-15 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-15 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-04-26 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-04-26 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2023-04-26 08:03:01 | 1ST GAS REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMEND 107.3.5.3 (13) - PLEASE SUBMIT A GAS | | | RISER DIAGRAM THAT INCLUDES ANY OF THE FOLLOWING | | | APPLICABLE ITEMS. LOCATION OF SHUT-OFFS, THE PIPING | | | MATERIAL, GAS PIPE SIZING METHOD AND BTU LOADS, THE | | | TYPE OF GAS PROPOSED, LP TANK OR METER LOCATION, AND | | | THE EXISTING GAS SYSTEM (LABELING EXISTING AND NEW FOR | | | CLARITY). | | | | | | 2. 2020 FRC R303.5.1 - RESIDENTIAL GAS GENERATORS MUST | | | BE 10 FEET FROM OPENINGS. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-06-13 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-05-12 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-05-09 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-04-21 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-15 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-15 |
Time |
07:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-04-26 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-04-26 |
Time |
08:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-04-25 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-04-25 |
Time |
18:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-06-13 |
|
|
Cont ID |
|
| Sent By |
avolcy |
Date |
2023-06-13 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-06-13 |
Time |
17:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
gvolcy |
Date |
2023-05-09 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
avolcy |
Date |
2023-05-09 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2023-05-09 10:58:00 | 05.09.2023 - FAILED | | | | | | PER ZONING AND LAND DEVELOPMENT REGULATIONS CODE | | | SECTION 94-305(B)(4): | | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN FOUR | | | FEET INTO A SETBACK. | | | THE SIDE SETBACK IS A MINIMUM 10FT. THE GENERATOR HAS | | | TO BE SETBACK 6FT TO MEET ZONING CODE. UPDATE | | | SURVEY/PLAN TO ILLUSTRATE THAT THIS REQUIREMENT IS | | | BEING MET. | | | | | | | | | MECHANICAL EQUIPMENT SHALL BE SCREENED FROM STREET AND | | | ADJACENT PROPERTY VIEW. | | | | | | **REVIEWED BY: | | | GAISHA (ANNE) VOLCY | | | PLANNER | | | [email protected] |
|
|