| Plan Review Stops For Permit 23041044 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-17 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-17 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-10 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-10 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2023-07-10 14:06:26 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL14083-R28 SYSTEM NO. SC-315 DOES NOT MEET | | | THE MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF | | | -108.17 FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM | | | THAT MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS | | | FOR EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED | | | ENGINEERED NAILING CALCULATIONS WITH AN APPROVED | | | SYSTEM. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-30 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-30 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2023-06-30 11:37:20 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | PLEASE ADDRESS PREVIOUS COMMENTS BELOW DATED 06/21/2023 | | | AND RESUBMIT. | | | | | | 1. FBC B 107.2.1. PROVIDE THE FOLLOWING INFORMATION FOR | | | FLORIDA PRODUCT APPROVAL FL14083-R28 FOR THE PROPOSED | | | FLAT ROOF RECOVER SYSTEM TO BE USED CORRESPONDING TO | | | ENGINEERS MEMBRANE ATTACHMENT CALCULATIONS. EVALUATION | | | REPORT PAGES #1-5, INSTALLATION INSTRUCTIONS FOR SYSTEM | | | R-79 PAGE #97. ALL APPLICABLE DETAILS AND ATTACHMENTS | | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | | DRAWINGS. SUBMITTED EVALUATION REPORT & INSTALLATION | | | INSTRUCTIONS ARE FOR FL14083-R26. | | | 2. FBC R 301 FAC9N-3. PROVIDE REROOF SYSTEM NUMBER & | | | INSTALLATION INSTRUCTIONS PAGE FOR THE MAIN CENTER ROOF | | | & LOWER NORTH ROOF AREAS TO BE REMOVED AND REPLACED AS | | | PER THE SUBMITTED ROOF MOISTURE REPORT. PROVIDE SIGNED | | | AND SEALED CALCULATIONS IF SYSTEM SELECTED DOES NOT | | | MEET MINIMUM DESIGN PRESSURE REQUIREMENTS. PLEASE NOTE: | | | PRODUCT APPROVAL FL14083-R28 WAS REVISED TO FL14083-R29 | | | ON JUNE 20, 2023. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-21 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-21 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2023-06-21 12:56:07 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. PROVIDE THE FOLLOWING INFORMATION FOR | | | FLORIDA PRODUCT APPROVAL FL14083-R28 FOR THE PROPOSED | | | FLAT ROOF RECOVER SYSTEM TO BE USED CORRESPONDING TO | | | ENGINEERS MEMBRANE ATTACHMENT CALCULATIONS. EVALUATION | | | REPORT PAGES #1-5, INSTALLATION INSTRUCTIONS FOR SYSTEM | | | R-79 PAGE #97. ALL APPLICABLE DETAILS AND ATTACHMENTS | | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | | DRAWINGS. SUBMITTED EVALUATION REPORT & INSTALLATION | | | INSTRUCTIONS ARE FOR FL14083-R26. | | | 2. FBC R 301 FAC9N-3. PROVIDE REROOF SYSTEM NUMBER & | | | INSTALLATION INSTRUCTIONS PAGE FOR THE MAIN CENTER ROOF | | | & LOWER NORTH ROOF AREAS TO BE REMOVED AND REPLACED AS | | | PER THE SUBMITTED ROOF MOISTURE REPORT. PROVIDE SIGNED | | | AND SEALED CALCULATIONS IF SYSTEM SELECTED DOES NOT | | | MEET MINIMUM DESIGN PRESSURE REQUIREMENTS. PLEASE NOTE: | | | PRODUCT APPROVAL FL14083-R28 WAS REVISED TO FL14083-R29 | | | ON JUNE 20, 2023. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-06-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-02 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-02 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2023-06-02 09:30:59 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL14083-R26 HAS BEEN | | | REVISED TO FL14083-R28. PLEASE PROVIDE THE FOLLOWING: | | | COVER PAGE, EVALUATION REPORT PAGES 1-5 AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | | RULE 61G20-3. | | | 2. FBC B 107.2.1. REVISE SUBMITTED MEMBRANE ATTACHMENT | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER TO UPDATE PRODUCT | | | APPROVAL TO THE CURRENT APPROVED VERSION | | | FL14083-R28; INCLUDE UPDATED SYSTEM/PAGE NUMBER TO BE | | | USED. | | | 3. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE | | | REPORT PREPARED BY A FLORIDA REGISTERED DESIGN | | | PROFESSIONAL. SECOND REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-08 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-08 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2023-05-08 09:00:43 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL16440-R24 | | | (HVHZ) IS NOT APPROVED FOR USE OUTSIDE HVHZ. CITY OF | | | WEST PALM BEACH IS NOT LOCATED IN A HVHZ. YOU MIGHT | | | CONSIDER USING FL14083-R28 (NON-HVHZ). PROVIDE THE | | | FOLLOWING: COVER PAGE, EVALUATION REPORTS PAGES 1-5 TO | | | INCLUDE LIMITATIONS PAGE(S) AND INSTALLATION | | | INSTRUCTIONS FOR SYSTEM USED. SELECT SYSTEM THAT MEETS | | | OR EXCEEDS EXPOSURE CATEGORY C MINIMUM DESIGN PRESSURE | | | ZONE 3 REQUIREMENTS OF -108.17. SIGNED AND SEALED | | | NAILING CALCULATIONS MAY BE REQUIRED. | | | 2. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH | | | TESTING APPLICATION STANDARD TAS 124 AS REQUIRED BY | | | LIMITATIONS 5.6.1 OF PRODUCT APPROVAL FL14083. | | | 3. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE | | | REPORT PREPARED BY A FLORIDA REGISTERED DESIGN | | | PROFESSIONAL. | | | 4. FBC B 107.2.1 PROVIDE A SIGN AND SEALED ROOF | | | DRAINAGE PLAN THAT COMPLIES WITH SECTION 1503 OF THE | | | 2020 FBC-BUILDING AND CHAPTER 11 OF THE 2020 | | | FBC-PLUMBING. | | | 5. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | | DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW | | | ROOFING CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF | | | SLOPE(S), MEAN ROOF HEIGHT(S). | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-17 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-14 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-10 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-06 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-30 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-22 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-21 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-09 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-02 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-26 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-08 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-05 |
Time |
10:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-17 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-17 |
Time |
14:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-06-09 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-06-09 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2023-06-09 09:06:46 | 6/9/23 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS PASSED | | | AND ROUTED TO STORAGE.MP |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-06-02 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-02 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-02 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2023-06-02 09:33:33 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | PENDING REVISED MEMBRANE ATTACHMENT CALCULATIONS. | | | DRAINAGE CALCS & PULL TEST SIGNATURES PASSED. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|