|
 |
 |
 |
 |
 |
Plan Review Details - Permit 23041017
| Plan Review Stops For Permit 23041017 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-24 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-24 |
Time |
16:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-25 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-25 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-24 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-24 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2023-04-24 16:33:24 | BUILDING PLAN REVIEW STATUS: FAILED | | | | | | FLOORING SUBMITTAL | | | | | | | | | ITEMS TO PROVIDE: | | | 1. FLOOR PLAN LAYOUT TO SHOW DIMENSIONS, AREA AND TYPE | | | OF FLOORING FOR EACH AREA. | | | | | | PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE | | | PROPOSED? PLEASE ADVISE VIA EMAIL - [email protected] | | | IF THE UNDERLAYMENT PRODUCT PROPOSED IS NOT ONE FOR | | | WHICH WE HAVE TEST REPORTS ON FILE, THE FOLLOWING | | | REPORTS ARE REQUIRED: | | | | | | 2. [FBC 1207.2]AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS AND SLEEPING UNITS FROM EACH | | | OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A | | | SOUND TRANSMISSION CLASS OF NOT LESS THAN 50, OR NOT | | | LESS THAN 45 IF FIELD TESTED, FOR AIR-BORNE NOISE WHEN | | | TESTED IN ACCORDANCE WITH ASTM E90. | | | | | | 3. [FBC 1207.3]STRUCTURE-BORNE SOUND. FLOOR/CEILING | | | ASSEMBLIES | | | BETWEEN DWELLING UNITS AND SLEEPING UNITS OR BETWEEN A | | | DWELLING | | | UNIT OR SLEEPING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN | | | THE STRUCTURE SHALL HAVE AN IMPACT INSULATION CLASS | | | RATING OF | | | NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED, | | | WHEN TESTED | | | IN ACCORDANCE WITH ASTM E492. | | | | | | 4. [FBC 603.1]ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT US: | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-09 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-05-09 |
Time |
15:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-24 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-04-27 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2023-04-27 13:55:40 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION ON THE SUBMITTED PLAN: | | | "INSTALL NEW LUXURY VINYL PLANK(LVP) THROUGHOUT", | | | HOWEVER, THERE IS NO INDICATION OF THE ACTUAL FLOOR | | | PRODUCT NOR NAME. | | | | | | LVT FLOORING CAN BE MANUFACTURED AROUND THE WORLD AND | | | NOT ALL ARE TESTED AND MEETING LISTED AND NFPA | | | STANDARDS. | | | | | | PER NFPA 101, CH 30 | | | | | | 30.3.3.3 INTERIOR FLOOR FINISH. | | | 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN | | | ACCORDANCE WITH | | | SECTION 10.2. | | | | | | 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH | | | 10.2.2.2 | | | ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL | | | HAVE A | | | MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE FLOORING | | | PRODUCT NAME AND THE PRODUCT SPEC SHEETS OF THE | | | PROPOSED FINISHED FLOORING INDICATING THE FIRE BEHAVIOR | | | RATING. | | | | | | IF THE PROPOSED FLOORING IS PORCELAIN/CERAMIC TILE, | | | NATURAL STONE TILE, CONCRETE TILES, PRODUCT SPEC SHEETS | | | WOULD NOT BE REQUIRED. | | | | | | PRODUCT SPEC SHEETS ARE REQUIRED FOR LVT, VINYL | | | FLOORING, WOOD/VINYL LAMINATES, ETC. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-25 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-23 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-09 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-04-21 |
Time |
12:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-26 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-26 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-24 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-24 |
Time |
16:21 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |