| Plan Review Stops For Permit 23041012 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-26 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-26 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-11 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-11 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-26 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-26 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2023-04-26 12:14:19 | | | | PLEASE PROVIDE FOORING UNDELAYEMENT FBC PRODUCT | | | APPROVAL AND SOUND TESTING RESULTS | | | ALSO PROVIDE | | | FLAME SPREAD REPORT FOR THE SELECTED UNDERLAYMENT AND | | | ALL FLOORING MATERIAL FOR THE PROJECT. | | | | | | | | | | | | FLOORING SUBMITTAL | | | ITEMS TO PROVIDE: | | | 1. FLOOR PLAN LAYOUT TO SHOW DIMENSIONS, AREA AND TYPE | | | OF FLOORING FOR EACH AREA. | | | | | | PLEASE ADVISE, WHAT FLOORING AND UNDERLAYMENT ARE | | | PROPOSED? | | | | | | 3. [FBC 1207.2]AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS AND SLEEPING UNITS FROM EACH | | | OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A | | | SOUND TRANSMISSION CLASS OF NOT LESS THAN 50, OR NOT | | | LESS THAN 45 IF FIELD TESTED, FOR AIR-BORNE NOISE WHEN | | | TESTED IN ACCORDANCE WITH ASTM E90. | | | | | | 4. [FBC 1207.3]STRUCTURE-BORNE SOUND. FLOOR/CEILING | | | ASSEMBLIES | | | BETWEEN DWELLING UNITS AND SLEEPING UNITS OR BETWEEN A | | | DWELLING | | | UNIT OR SLEEPING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN | | | THE STRUCTURE SHALL HAVE AN IMPACT INSULATION CLASS | | | RATING OF | | | NOT LESS THAN 50, OR NOT LESS THAN 45 IF FIELD TESTED, | | | WHEN TESTED | | | IN ACCORDANCE WITH ASTM E492. | | | | | | 5. [FBC 603.1]ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | | OR UL 723. | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS PLEASE DO NOT | | | HESITATE TO CONTACT US | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-05-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-19 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-05-19 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-08 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-05-08 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2023-05-08 12:18:17 | | | | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NEED TO SUBMIT AN ELECTRICAL LAYOUT SHOWING ALL NEW | | | ELECTRIC. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-11 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2023-05-11 11:22:46 | FIRE PROVISO: | | | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | | | PROTECT FIRE ALARM DEVICES AND EQUIPMENT. | | | | | | DO NOT PAINT OVER FIRE ALARM DEVICES OR EQUIPMENT. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-04-26 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2023-04-27 13:09:22 | FIRE PROVISO: | | | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | | | PROTECT FIRE ALARM DEVICES AND EQUIPMENT. | | | | | | DO NOT PAINT OVER FIRE ALARM DEVICES OR EQUIPMENT. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-19 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-19 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-05-10 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-08 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-04-20 |
Time |
12:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2023-05-03 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-03 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-03 |
Time |
09:43 |
Sent To |
|
|
| Notes |
| 2023-05-03 09:44:36 | NO MECHANICAL PERMIT REQUIRED FOR THE MECHANICAL SHOWN | | | IN THE CONTRACT. ME |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-12 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-12 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-04-21 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-04-21 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-04-21 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2023-04-21 11:44:15 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2017 WPB AMENDS 107.3.5.1.3 - PLEASE INCLUDE A | | | PLUMBING PLAN THAT SHOWS THE NEW FIXTURES AND THEIR | | | INTENDED CONNECTIONS TO THE SANITARY SYSTEM. | | | | | | 2. 2020 FPC 315.1 - AS A NOTE - NEW PENETRATIONS IN THE | | | FLOORS, WALLS, OR CEILING AS WELL AS ABANDONED | | | PENETRATIONS WILL NEED A UL LISTED FIRE STOPPING DETAIL | | | SUBMITTED AND REVIEWED BY THE BUILDING REVIEW AND | | | SHOULD BE INCLUDED IN THE A PAGES. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-11 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-11 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-26 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-26 |
Time |
11:58 |
Sent To |
|
|
| Notes |
|
|