Plan Review Details - Permit 23041010
Plan Review Stops For Permit 23041010
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-06-29 Cont ID  
Sent By rmcphers Date 2023-06-29 Time 10:06 Rev Time 0.00
Received By rmcphers Date 2023-06-29 Time 10:05 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-05-17 Cont ID  
Sent By rmcphers Date 2023-05-17 Time 09:57 Rev Time 0.00
Received By rmcphers Date 2023-05-17 Time 09:57 Sent To  
Notes
2023-05-17 09:58:43PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-06-29 Cont ID  
Sent By rmcphers Date 2023-06-29 Time 10:16 Rev Time 0.00
Received By rmcphers Date 2023-06-29 Time 10:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-17 Cont ID  
Sent By rmcphers Date 2023-05-17 Time 09:57 Rev Time 0.00
Received By rmcphers Date 2023-05-17 Time 09:49 Sent To  
Notes
2023-05-17 10:18:35REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) THE T, G AND A DRAWINGS DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-05-19 Cont ID  
Sent By jleahy Date 2023-05-19 Time 17:12 Rev Time 0.00
Received By jleahy Date 2023-05-19 Time 16:06 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-06-30 Cont ID  
Sent By clfranci Date 2023-06-30 Time   Rev Time 0.00
Received By clfranci Date 2023-06-30 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-04-27 Cont ID  
Sent By pleduc Date 2023-04-27 Time   Rev Time 0.00
Received By pleduc Date 2023-04-25 Time 15:37 Sent To  
Notes
2023-04-25 15:37:50FIRE PREVENTION COMMENT:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2023-07-15 Time   Rev Time 0.00
Received By amcgrego Date 2023-06-28 Time 17:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-19 Cont ID  
Sent By jleahy Date 2023-05-19 Time 17:12 Rev Time 0.00
Received By jleahy Date 2023-04-20 Time 12:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-07-15 Cont ID  
Sent By ccole Date 2023-07-15 Time 09:39 Rev Time 0.00
Received By ccole Date 2023-07-15 Time 09:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-05-17 Cont ID  
Sent By ccole Date 2023-05-17 Time 16:00 Rev Time 0.00
Received By ccole Date 2023-05-17 Time 15:40 Sent To  
Notes
2023-05-17 16:00:361ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23041010
 5/17/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1.1 & P2.1: THE PLAN APPEARS TO SHOW
 DRAINAGE FROM THE HAND SINK (BR6) AND THE DROP IN ICE
 AND SODA DISPENSER (BR9) DISCHARGING INTO THE GREASE
 WASTE LINE WHICH IS PROHIBITED ACCORDING TO SEC.
 1003.3.1 FBC P. PLEASE NOTE GREASE INTERCEPTORS SHALL
 RECEIVE WASTE ONLY FROM FIXTURES AND EQUIPMENT THAT
 ALLOW FATS, OILS OR GREASE TO BE DISCHARGED. PLEASE
 CLARIFY THE CONTENT OF THE DRAINAGE FROM THE OTHER BAR
 FIXTURES TO DETERMINE IF THEY SHOULD BE DRAINING INTO
 THE GREASE WASTE LINE OR SANITARY LINE.
  
 2) P1.1 SANITARY ISOMETRIC: SHOW A TRAP AND VENT FOR
 THE HAND SINK- SECS. 901.2.1 & 1002.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-06-29 Cont ID  
Sent By rmcphers Date 2023-06-29 Time 10:10 Rev Time 0.00
Received By rmcphers Date 2023-06-29 Time 10:10 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-05-17 Cont ID  
Sent By rmcphers Date 2023-05-17 Time 10:18 Rev Time 0.00
Received By rmcphers Date 2023-05-17 Time 10:18 Sent To  
Notes
2023-05-17 10:19:09SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) THE T, G AND A DRAWINGS DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).