Plan Review Details - Permit 23040992
| Plan Review Stops For Permit 23040992 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-26 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-05-26 |
Time |
08:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-04 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-05-04 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2023-05-04 15:58:34 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT COPIES OF THE ACTUAL TEST REPORTS FOR THE | | | SOUND INSULATION INCLUDING FLAME SPREAD AND SMOKE | | | DEVELOPED FOR THE APPLICABLE CONSTRUCTION CONDITIONS. | | | THE PRODUCT HAS TO BE TESTED WITH THE SAME SLAB | | | THICKNESS AND CONDITIONS THAT EXIST AT THE LOCATION | | | WHERE IT WILL BE INSTALLED. | | | FBC 603.1 FLAME SPREAD - ASTM E 84-09 | | | | | | FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04 | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09 | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-11 |
Time |
12:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-04-20 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-04-20 10:04:10 | FIRE REVIEW COMMENTS: | | | | | | PROVIDE TEST DATA FOR THE VINYL FLOOR FIRE PERFORMANCE | | | TO INCLUDE THE CRITICAL RADIANT FLUX OF THE MATERIALS | | | TO BE INSTALLED. NFPA 101, 10.2.7 | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-26 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-05-10 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-04 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-19 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-05-04 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-05-04 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy