| Plan Review Stops For Permit 23040991 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-26 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-26 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2023-07-26 11:16:37 | THE SITE PLAN AND ELECTRICAL/SITE DRAINAGE PLANS | | | REQUIRE THE NAME AND SIGNATURE OF THE | | | DESIGNER/CONTRACTOR. CT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-24 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2023-05-24 12:43:19 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICED: PLAN PAGE SO (WIND LOAD DESIGN) AND ALL OTHER | | | STRUCTURAL PLANS REQUIRE THE PRINTED NAME AND SIGNATURE | | | OF THE DESIGNER. | | | | | | 1.THE OWNER/BUILDER, CONTRACTOR OR DESIGNER OF RECORD | | | SHALL PROVIDE THEIR PRINTED NAME AND SIGNATURE ON PLAN | | | SHEETS UNDER THEIR AUTHORITY. | | | 2017 WPB AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1, SECTION 107.2.1. | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5), CHPT. 471, F.S. & 61G15 AND CHPT. | | | 481, F.S. & 61G1. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-07-10 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-07-10 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-07-10 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2023-07-10 08:43:10 | ELECTRICAL REVIEW FAILED | | | | | | 1) ELECTRICAL PLAN STILL DOES NOT DETAIL THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | WEST PALM BEACH AMENDMENT 107.2 | | | | | | 2) PLAN STILL DETAILS EQUIPMENT POWERED THROUGH AN | | | ELECTRIC RECEPTACLE. STUXURE CONTROL BOX. | | | | | | NEC 400.12 USES NOT PERMITTED. | | | UNLESS SPECIFICALLY PERMITTED IN 400.10, FLEXIBLE | | | CABLES, FLEXIBLE CORD SETS, AND POWER SUPPLY CORDS | | | SHALL NOT BE USED FOR THE FOLLOWING: | | | (1) AS A SUBSTITUTE FOR THE FIXED WIRING OF A STRUCTURE | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | . | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-05-19 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-05-19 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-05-19 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2023-05-19 12:50:00 | ELECTRICAL REVIEW FAILED | | | | | | 1) ELECTRICAL PLAN IS REQUIRED TO BEAR THE NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. | | | WEST PALM BEACH AMENDMENT 107.2 | | | | | | 2) PLAN DETAILS EQUIPMENT POWERED THROUGH AN ELECTRIC | | | RECEPTACLE. EQUIPMENT. | | | NEC 400.12 USES NOT PERMITTED. | | | UNLESS SPECIFICALLY PERMITTED IN 400.10, FLEXIBLE | | | CABLES, FLEXIBLE CORD SETS, AND POWER SUPPLY CORDS | | | SHALL NOT BE USED FOR THE FOLLOWING: | | | (1) AS A SUBSTITUTE FOR THE FIXED WIRING OF A | | | STRUCTURE. | | | | | | 3) PLEASE PROVIDE AN ELECTRICAL FLOOR/SITE PLAN | | | LOCATING ALL EQUIPMENT SHOWN IN SCHEMATIC DRAWING. FBC | | | 107.2 | | | | | | 4) PLAN DETAILS AN NEW 225 AMP ELECTRIC PANEL. NOTES | | | CONTAINED IN THIS PLAN INDICATE THIS PANEL TO BE | | | INSTALLED BY OTHERS. PLEASE PROVIDE THE APPLICABLE | | | PERMIT APPLICATION AND PLANS FOR NEW PANEL. FBC 107.2 | | | | | | 5) PLEASE PROVIDE DETAILS OF WIRE METHODS USED FOR ALL | | | WIRING. NEC 110.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-26 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-03 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-05-25 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-24 |
Time |
17:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-07-26 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-07-26 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2023-07-26 11:16:21 | ALL PLAN PAGES WITH DESIGN PROFESSIONAL SIGNATURES AND | | | SEALS HAVE VALID DIGITAL SIGNATURES. | | | THE SITE PLAN AND ELECTRICAL/SITE DRAINAGE PLANS | | | REQUIRES THE NAME AND SIGNATURE OF THE | | | DESIGNER/CONTRACTOR. CT |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-24 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-24 |
Time |
08:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-07-11 |
|
|
Cont ID |
|
| Sent By |
lngelman |
Date |
2023-07-11 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-07-11 |
Time |
13:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
lgelman |
Date |
2023-05-24 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-05-24 |
Time |
17:27 |
Sent To |
|
|
| Notes |
|
|